background image

Instruction Manual

HI 931002

4-20 mA  Simulator

h t t p : / / w w w . h a n n a i n s t . c o m

These Instruments are in

Compliance with the CE Directives

Summary of Contents for HI 931002

Page 1: ...Instruction Manual HI 931002 4 20 mA Simulator h t t p w w w h a n n a i n s t c o m These Instruments are in Compliance with the CE Directives ...

Page 2: ... an external adapter included which is connected to the simulator This mode is ideal for calibrating chart recorders pressure transducers or current indicators 3 Passive Measurement Tester Mode HI 931002 practically be comes an Ammeter It measures and displays the mA or pH values transmitted by the process meter 4 Active Measurement Tester Mode Same as point 3 in addition to providing voltage to t...

Page 3: ...d P to terminals Turn the Fine and Coarse knobs to any desired value and make sure that the D U T reflects the current value displayed on the HI 931002 LCD Calibrate the D U T according to manufacturer instructions if necessary Range Active Drive 2 00 to 19 99 mA 1 50 to 14 00 pH Passive Drive 2 00 to 19 99 mA 1 50 to 14 00 pH Active Measure 0 00 to 19 99 mA 3 50 to 14 00 pH Passive Measure 0 00 t...

Page 4: ...L FUSE ACTIVE DRIVE SIMULATOR MODE This mode is intended to drive a chart recorder calibrate a pressure current transducer or a current indicator The HI 931002 supplies a voltage to the 4 20 mA bus via an external connected 12 32 VDC power supply The calibrator regulates the current displayed on the LCD as in the previous mode Passive Drive Turn the meter on by pressing the ON OFF key Select the m...

Page 5: ...d range The read ing will toggle between the mA and pH reading mA pH RELATION mA pH RELATION mA pH RELATION mA pH RELATION mA pH RELATION ACTIVE MEASURING TESTER MODE This mode is intended to test a passive transmitter The HI 931002 supplies only the power to the 4 20 mA bus via an external connected 12 32 VDC power supply and displays the value of the current produced by the transmitter Turn the ...

Page 6: ...rchased the instrument If under warranty report the model number date of pur chase serial number and the nature of the failure If the repair is not covered by the warranty you will be notified of the charges incurred If the instrument is to be returned to Hanna Instruments first obtain a Returned Goods Authorization number from the Customer Service depart ment and then send it with shipping costs ...

Page 7: ...PRINTED IN PORTUGAL MN931002R1 04 98 h t t p w w w h a n n a i n s t c o m ...