Remove the instrument from the packing material and examine it
carefully to make sure that no damage has occurred during shipping.
If there is any damage, immediately notify your dealer.
Each meter is supplied complete with:

HI 70604/2 

RH probe with 2 m cable

HI 762L/2 

temperature probe with 2 m cable

• 5 paper rolls
• Batteries (4 x 1.5V AA)
• Instruction manual
• Rugged carrying case

Note:

 Save all packing material until you are sure that the

instrument functions correctly. Any defective item must be
returned in their original packaging together with the sup-
plied accessories.

PRELIMINARY EXAMINATION

Dear Customer,
Thank you for choosing a HANNA instruments

®

 product.

Please read this instruction manual carefully before using the instru-
ment.
This manual will provide you with the necessary information for the
correct use of the instrument, as well as a precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail
us at 

[email protected].

These instruments are in compliance with the 

 directives.

TABLE OF CONTENTS

WARRANTY .................................................................................. 3
PRELIMINARY EXAMINATION ........................................................ 3
GENERAL DESCRIPTION ................................................................ 4
FUNCTIONAL DESCRIPTION HI 9161 ............................................ 5
FUNCTIONAL DESCRIPTION HI 91610 .......................................... 6
FUNCTIONAL DESCRIPTION DISPLAY AND RH PROBE .................... 7
SPECIFICATIONS ........................................................................... 8
INITIAL PREPARATION ................................................................. 9
OPERATIONAL GUIDE ................................................................. 10
PRINTING/RECORDING WITH HI 9161 ........................................ 17
PRINTING/LOGGING WITH HI 91610 .......................................... 19
CALIBRATION ............................................................................. 24
DATA TRANSFER TO PC (HI 91610 only) .................................... 27
SELF-DIAGNOSTIC FUNCTIONS .................................................... 28
MEMORY ORGANIZATION (HI 91610 only) ................................. 28
BATTERY REPLACEMENT .............................................................. 29
PRINTER MAINTENANCE ............................................................. 30
ACCESSORIES ............................................................................. 32
CE DECLARATION OF CONFORMITY .............................................. 35

WARRANTY

All Hanna Instruments

 meters are warranted for two years

against defects in workmanship and materials when used for their
intended purpose and maintained according to instructions.

The probes are warranted for a period of six months.

This warranty is limited to repair or replacement free of charge

.

Damages due to accidents, misuse, tampering or lack of prescribed
maintenance are not covered. If service is required, contact the dealer
from whom you purchased the instrument. If under warranty, report
the model number, date of purchase, serial number and the nature
of the failure. If the repair is not covered by the warranty, you will be
notified of the charges incurred. If the instrument is to be returned to
Hanna Instruments, first obtain a Returned Goods Authorization
Number from the Customer Service department and then send it with
shipment costs prepaid. When shipping any instrument, make sure it
is properly packaged for complete protection.

All rights are reserved. Reproduction in whole or in part is prohibited without the
written consent of the copyright owner, Hanna Instruments.

Summary of Contents for HI 91610

Page 1: ...9161C ON OFF PAPER RANGE RH 5 0 95 0 C 20 0 60 0 INTV instrum nts e UP PRINT DOWN RANGE LOG MICROPROCESSOR PRINTING THERMOHYGROMETER HI 9161 HI 91610 Printing and Logging Thermo Hygrometers w w w h a...

Page 2: ...CIFICATIONS 8 INITIAL PREPARATION 9 OPERATIONAL GUIDE 10 PRINTING RECORDING WITH HI 9161 17 PRINTING LOGGING WITH HI 91610 19 CALIBRATION 24 DATA TRANSFER TO PC HI 91610 only 27 SELF DIAGNOSTIC FUNCTI...

Page 3: ...ecording printing interval relative humidity and temperature at user selectable intervals Both RH and temperature are measured with 0 1 resolution HI 91610 combines the high accuracy and portability o...

Page 4: ...terval 6 TIME key to display current time and printing interval or to set date time printing interval with ALT 7 LOG key to start stop logging with ALT 8 LCD Liquid Crystal Display 9 PAPER key to adva...

Page 5: ...se However when in recording logging mode the meter will continue to monitor RH and temperature To reactivate the display press RANGE INITIAL PREPARATION ON OFF RANGE RANGE SPECIFICATIONS HI 9161C HI...

Page 6: ...ff until moisture has completely evaporated To accelerate the evaporation process expose the humidity sensor to a current of air For any problem in taking measurements please contact your dealer or th...

Page 7: ...ng The printing interval on the secondary LCD will blink Any interval can be selected from among 1 2 5 10 15 30 60 120 and 180 minutes by using the UP and DOWN keys Once the desired interval is select...

Page 8: ...red in the memory even when the meter or display are switched off Note Each time the batteries are replaced the settings will need to be re entered This can be avoided by applying an external voltage...

Page 9: ...YY d Printing interval in minutes e Time HH MM f RH value g Temperature value When the meter is in recording mode LOG is displayed on the secondary LCD with the RH value on the primary LCD PRINT LOG V...

Page 10: ...will print a complete set of data and the LOG symbol will appear on the secondary LCD Press the ALT and PAPER keys at the same time and the LOG symbol on display will start to blink If no key is press...

Page 11: ...DOWN TIME LOG ALT RANGE LOG TIME To reactivate the display press the TIME key Notes Once in the logging mode the interval cannot be changed Exit the logging mode press ALT and LOG together and then s...

Page 12: ...the recall mode press the LOG key Note This mode will not alter data already present in the memory PRINTING STORED DATA Once a log number is selected all or part of that logged section can be printed...

Page 13: ...Na Cl 75 4 CALIBRATION KIT 12 3 6 9 4 h CALIBRATION KIT Li Cl 11 1 Na Cl 75 4 12 3 6 9 4 h All HANNA thermo hygrometers have been precalibrated at the factory HANNA instruments uses state of the art...

Page 14: ...0 you need a 3 5 drive and a couple of minutes to follow the short instructions conveniently printed on the disk label TIME Windows is a registered Trademark of Microsoft Co Excel Copyright of Microso...

Page 15: ...s for about 1 minute Remember to reset time and date once the batteries have been reinserted ATTENTION If batteries need to be replaced and data is not to be lost power the meter through a 12 Vdc adap...

Page 16: ...er the cover preventing the pa per from advancing Replace the battery cover and tighten the screws 1 5V 1 5V 1 5V 1 5V SCREW POTS RESET CHANGING THE INK CARTRIDGE When printouts become faint it might...

Page 17: ...handle HI 762BL Liquid probe with 1 m 3 3 cable black handle HI 762BL 10 Liquid probe with 10 m 33 cable black handle HI 762L Liquid probe with 1 m 3 3 cable white handle HI 762L 10 Liquid probe with...

Page 18: ...the probe socket on the meter If the reading differs by more than 0 4 C 0 8 F from the test key value the unit is due for recalibration Choose the proper test key according to your application needs H...

Page 19: ...42 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 0...

Reviews: