background image

20

WARRANTY

HI8666 is warranted for one year against
defects in workmanship and materials when
used for its intended purpose and main-
tained according to instructions.
This warranty is limited to repair or replace-
ment free of charge.

Damages due to accidents, misuse, tamper-
ing or lack of prescribed maintenance  are
not covered.

If service is required, contact the dealer
from whom you purchased the instrument.
If under warranty, report the model number,
date of purchase, serial number and the
nature of the failure. If the repair is not
covered by the warranty, you will be notified
of the charges incurred.  If the instrument is
to be returned to Hanna Instruments, first
obtain a Returned Goods Authorization Num-
ber from the Customer Service department
and then send it with shipments costs pre-
paid.  When shipping any instrument, make
sure it is properly packaged for complete
protection.

To validate your warranty, fill out and return
the enclosed warranty card within 14 days
from the date of purchase.

All rights are reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.

Hanna Instruments reserves the right to modify
the design, construction and appearance
of its products without advance notice.

Summary of Contents for HI 8666

Page 1: ...Instruction Manual HI 8666 RH C Transmitter This Instrument is in Compliance with the CE Directives w w w h a n n a i n s t c o m...

Page 2: ...of the instrument as well as a precise idea of its versatility in a wide range of applications This instrument is in compliance with direc tives EN 50081 1 and EN 50082 1 Preliminary Examination 1 Ge...

Page 3: ...ent transmits electrically isolated out puts that are linear and proportional to RH and C It can be surface or panel mounted and used with a detachable connector The power must be supplied from an ext...

Page 4: ...2 FUNCTIONAL DESCRIPTION 1 2 3 1 Sintered Cap 2 Relative Humidity and Temperature Sen sors 3 11 Pin Connector...

Page 5: ...to 40 C C 1 of span Typical EMC RH 2 5 RH 0 4 mA Deviation C 1 C 0 2 mA Output Signal 4 to 20 mA Response Time 6 without sintered filter 1 with filter Power Supply 12 to 24V externally supplied Maxim...

Page 6: ...CAL relay socket The terminals are 1 C Positive Terminal 9 C Negative Terminal 4 RH Positive Terminal 7 RH Negative Terminal Terminals 2 3 5 6 8 10 and 11 are not connected See the following figures f...

Page 7: ...d receivers Common positive 3 Passive and not isolated receivers Common negative RH Transmitter 4 7 1 9 Power Supply C Receiver RH Receiver C Transmitter RH Transmitter 7 4 9 1 Power Supply C Receiver...

Page 8: ...6 4 Active receivers both isolated or not RH Transmitter C Transmitter RH Receiver C Receiver 4 7 1 9...

Page 9: ...t includes two thermally isolated chambers each one equipped with a threaded cap and three bottles containing the appropriate precalibrated saturated salts to produce a known RH value This calibration...

Page 10: ...present in the air causing the solution to expand in volume and to overflow from the container Pour approximately 12 cc of distilled water into the other chamber marked RH 75 4 Add all the content of...

Page 11: ...ot to dip it into the liquid Wait for the measurement to stabilize this takes ap proximately 4 hours Look at the multimeter display the read ing should be 4 00 mA representing the theoretical chamber...

Page 12: ...tical chamber value of 75 4 RH The relative humidity calibration check ing procedure is complete If the therotical values are not within 1 contact your dealer or your closest Hanna Service Center for...

Page 13: ...for the temperature to stabilize Using a NIST certified thermometer as a reference e g ChecktempC N verify that the ammeter reading is matching the tem perature e g 13 00 mA for 25 C All temperature...

Page 14: ...10 6 256 14 20 6 272 14 30 6 288 14 40 6 304 14 50 6 320 14 60 6 336 14 70 6 352 14 80 6 368 14 90 6 384 15 00 6 400 15 10 6 416 15 20 6 432 15 30 6 448 15 40 6 464 15 50 6 480 15 60 6 496 15 70 6 512...

Page 15: ...2 44 00 11 04 44 10 11 05 44 20 11 07 44 30 11 08 44 40 11 10 44 50 11 12 44 60 11 13 44 70 11 15 44 80 11 16 44 90 11 18 45 00 11 20 45 10 11 21 45 20 11 23 45 30 11 24 45 40 11 26 45 50 11 28 45 60...

Page 16: ...2 74 00 15 84 74 10 15 85 74 20 15 87 74 30 15 88 74 40 15 90 74 50 15 92 74 60 15 93 74 70 15 95 74 80 15 96 74 90 15 98 75 00 16 00 75 10 16 01 75 20 16 03 75 30 16 04 75 40 16 06 75 50 16 08 75 60...

Page 17: ...0 19 04 94 10 19 05 94 20 19 07 94 30 19 08 94 40 19 10 94 50 19 12 94 60 19 13 94 70 19 15 94 80 19 16 94 90 19 18 95 00 19 20 95 10 19 21 95 20 19 23 95 30 19 24 95 40 19 26 95 50 19 28 95 60 19 29...

Page 18: ...0 6 800 6 9 6 820 5 8 6 840 5 7 6 860 5 6 6 880 5 5 6 900 5 4 6 920 5 3 6 940 5 2 6 960 5 1 6 980 5 0 7 000 4 9 7 020 4 8 7 040 4 7 7 060 4 6 7 080 4 5 7 100 4 4 7 120 4 3 7 140 4 2 7 160 4 1 7 180 4...

Page 19: ...12 78 24 00 12 80 24 10 12 82 24 20 12 84 24 30 12 86 24 40 12 88 24 50 12 90 24 60 12 92 24 70 12 94 24 80 12 96 24 90 12 98 25 00 13 00 25 10 13 02 25 20 13 04 25 30 13 06 25 40 13 08 25 50 13 10 2...

Page 20: ...17 78 49 00 17 80 49 10 17 82 49 20 17 84 49 30 17 86 49 40 17 88 49 50 17 90 49 60 17 92 49 70 17 94 49 80 17 96 49 90 17 98 50 00 18 00 50 10 18 02 50 20 18 04 50 30 18 06 50 40 18 08 50 50 18 10 5...

Page 21: ...ated salts LiCl and NaCl HI 7111 P Spare saturation salts 6 x 15 g bottles of LiCl for low range humidity calibration HI 7121 P Spare saturation salts 6 x 33 g bottles of NaCl for high humidity calibr...

Page 22: ...air is not covered by the warranty you will be notified of the charges incurred If the instrument is to be returned to Hanna Instruments first obtain a Returned Goods Authorization Num ber from the Cu...

Page 23: ...1996 D Volpato Engineering Manager On behalf of Hanna Instruments S r l HI 8666 Recommendations for Users Before using this product make sure that it is entirely suitable for the environment in which...