3.  GENERAL DESCRIPTION & INTENDED USE

HI9810392

 is a professional wireless pH tester, part of Hanna Instruments HALO2 family.

•  The integrated Bluetooth module allows the tester to be connected to a compatible smart device with the Hanna Lab App.

•  The tester has a compact, waterproof casing, and automatic pH calibration at up to three points, or four points when 

used with the Hanna Lab App.

•  Automatically compensated temperature readings are displayed on a large LCD.

•  Accurate and easy to use, the tester is ideal for pH measurement during the chocolate making process.

Operating Modes

The 

HI9810392

 can be used as a stand-alone pH tester or connected to the Hanna Lab App.

The Hanna Lab App turns a compatible smart device into a full-featured pH meter. Features include: electrode condition, 

GLP with time-stamp, live-readings, mV resolution, manual temperature compensation, stability criteria, calibration 

reminder, pH (mV) and temperature alarms, tester ID, and data sharing.

Probe Features

The rugged 

PVDF electrode body

 is easy to clean. Resistant to most chemicals (e.g. solvents, sodium hypochlorite), 

ultraviolet light, and fungal growth, the PVDF body also has high-abrasion resistance and mechanical strength.
The 

conical tip

 allows for easy penetration into solids and semisolids.

The 

PVDF

 

outer junction sleeve

 can be removed and cleaned. Once cleaned, a small amount of supplied gel electrolyte is 

added and the junction is refreshed, improving the measurement and extending the life of the tester.
The 

double junction

 design presents a silver-free electrolyte solution interacting with the sample, making the electrode 

less susceptible to clogging and guaranteeing a fast response and stable reading.
Built-in 

temperature sensor

 at the tip of the pH electrode allows for rapid determination of the sample temperature and a 

high-accuracy temperature reading.

4.  FUNCTIONAL DESCRIPTION & LCD DISPLAY

Front & Back view

Chocolate pH T

est

er

LCD

ON/OFF

button

Maximum immersion level

pH Probe

Recommended 

immersion level

 

Removable

sleeve

 

SN: XXXXXXXXX
Made in Romania

HI9810392

        

       2

 

1

    

0

4

-

0

1

-

0

A

6

8

7

0

9

2

21  :

CI    

40

B9

A

A 2    :

D I   

C C F   

s n i a t n

Co

R

Setup 

button

Battery cover

LCD display

&

!

#

œ.œ.œ.œ

88.8.8

7

6

5

10

9

8

1
2
3
4

1 Calibration indicator

2 Stability indicator

3 Battery percentage indicator

4 Battery icon

5 Bluetooth icon

6 Temperature compensation

7 Second LCD line

8 Temperature unit

9 First LCD line

10 Measurement unit

Summary of Contents for HALO 2 HI9810392

Page 1: ...INSTRUCTION MANUAL HI9810392 Wireless pH Tester for Chocolate with built in specialized electrode Foodcare ...

Page 2: ...g a Hanna Instruments product Please read this instruction manual carefully before using this instrument This manual will provide you with the necessary information for correct use of this instrument as well as a precise idea of its versatility If you need additional technical information do not hesitate to e mail us at tech hannainst com or view our contact list at www hannainst com Dear Customer...

Page 3: ...H Resolution 6 Bluetooth Wireless Mode 6 Bluetooth Pairing 7 Date Time 7 7 Bluetooth 7 8 Hanna Lab Application 7 Tag a Measurement 7 9 Calibration 7 Preparation Guidelines 7 Procedure 7 Stand Alone Tester Up to Three Point Calibration 8 With Hanna Lab App Up to Four Point Calibration 8 10 Care Maintenance 8 Refilling the Electrode 9 Storage 9 11 Warning Error Messages 9 12 Abbreviations 9 13 Acces...

Page 4: ...0 to 140 0 F Resolution pH 0 01 or 0 1 pH mV 0 1 or 1 mV Temperature 0 1 C 0 1 F Accuracy pH 0 05 pH Temperature 0 5 C 0 9 F Calibration Up to three points or four points Automatic buffer recognition with Standard buffers Hanna pH 1 68 4 01 7 01 10 01 or NIST pH 1 68 4 01 6 86 9 18 Temperature compensation Automatic ATC or Manual MTC Electrode Body material Polyvinylidene Fluoride PVDF Glass Low T...

Page 5: ...ultraviolet light and fungal growth the PVDF body also has high abrasion resistance and mechanical strength The conical tip allows for easy penetration into solids and semisolids The PVDF outer junction sleeve can be removed and cleaned Once cleaned a small amount of supplied gel electrolyte is added and the junction is refreshed improving the measurement and extending the life of the tester The d...

Page 6: ...use specified battery type Dispose of old battery in accordance with local regulations 6 SETUP The Setup button is located inside the battery compartment After Setup configuration replace the cover Setup Menu Navigation Press the Setup button to enter Setup mode and navigate menu items To exit Setup mode press the Setup button after SEt TIME option is displayed Press the ON OFF button to configure...

Page 7: ...hen the tester is in discoverable mode it will appear in the list of Available Devices Within the application tap Connect to pair the tester with the device All readings are transmitted directly to the application Tag a Measurement Once connected to the application the ON OFF button can be pressed to tag the current reading Press the ON OFF button from measurement mode The display shows SEt TAG fo...

Page 8: ...de automatically With 3P option selected 6 Place the tip of the electrode in the second buffer rinse beaker then in the second calibration buffer Wait until the measurement is stored and the stability indicator disappears 7 Place the tip of the electrode in the third buffer rinse beaker then in the third calibration buffer Wait until the measurement is stored and the stability indicator disappears...

Page 9: ... minimum of 30 minutes before calibrating Storage To ensure a quick response the glass tip and junction should be kept hydrated When not in use add a few drops of storage solution to the storage cap If storage solution is not available pH 4 01 or pH 7 01 buffer can be used Note Do not store the electrode in distilled or deionized water 11 WARNING ERROR MESSAGES WRNG WRNG displayed during calibrati...

Page 10: ...using this product make sure it is entirely suitable for your specific application and for the environment in which it is used Any variation introduced by the user to the supplied equipment may degrade the tester s performance For your and the tester s safety do not use or store it in hazardous environments WARRANTY HI9810392 is warranted for a period of one year against defects in workmanship and...

Page 11: ...ovide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interferenc...

Page 12: ...World Headquarters Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com MAN9810392 Printed in ROMANIA ...

Reviews: