14.  ACCESSORIES

Ordering Information Product Description

pH Buffer Solution

HI50016-02

pH 1.68 buffer solution, 20 mL sachet (25 pcs.)

HI70004G

GroLine pH 4.01 buffer solution, 20 mL sachet (25 pcs.)

HI70006P

pH 6.86 buffer solution, 20 mL sachet (25 pcs.)

HI70007G

GroLine pH 7.01 buffer solution, 20 mL sachet (25 pcs.)

HI70009P

pH 9.18 buffer solution, 20 mL sachet (25 pcs.)

HI70010P

pH 10.01 buffer solution, 20 mL sachet (25 pcs.)

HI77400P

pH 4.01 & 7.01 buffer solution, 20 mL sachet (10 pcs., 5 each)

HI770710P

pH 10.01 & 7.01 buffer solution, 20 mL sachet (10 pcs., 5 each)

Electrode Cleaning Solution

HI70061G

GroLine general purpose cleaning solution, 20 mL sachet (25 pcs.)

HI700661P

General purpose cleaning solution for agriculture, 20 mL sachet (25 pcs.)

HI700663P

Cleaning solution for soil deposits, 20 mL sachet (25 pcs.)

HI700664P

Cleaning solution for humus deposits, 20 mL sachet (25 pcs.)

Electrode Storage Solution

HI70300G

GroLine electrode storage solution, 20 mL sachet (25 pcs.)

HI70300-023

GroLine electrode storage solution, 230 mL

Electrode Fill Solution

HI9071

Gelled bridge electrolyte, 13 mL dropper bottle

Other Accessories

HI7051M

Soil preparation solution, 230 mL

HI721319

Soil auger

RECOMMENDATIONS FOR USERS

Before using this product, make sure it is entirely suitable for your specific application and for the environment in which it is 

used. Any variation introduced by the user to the supplied equipment may degrade the tester’s performance. For your and the 

tester’s safety do not use or store it in hazardous environments.

WARRANTY

HI9810302

 is warranted for a period of one year against defects in workmanship and materials when used for its intended 

purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge. Damage due 

to accidents, misuse, tampering, or lack of prescribed maintenance is not covered. If service is required, contact your local Hanna 

Instruments office. If under warranty, report the model number, date of purchase, serial number, and the nature of the problem. 

If the repair is not covered by the warranty, you will be notified of the charges incurred. If the tester is to be returned to Hanna 

Instruments, first obtain a Returned Goods Authorization (RGA) number from the Technical Service department and then send it 

with shipping costs prepaid. When shipping any product, make sure it is shipped back in compliance with shipping regulations, 

thoroughly cleaned and free of any chemicals, and is properly packaged for complete protection.

All manuals and user guides at all-guides.com

Summary of Contents for GroLine HALO2 HI9810302

Page 1: ...INSTRUCTION MANUAL HI9810302 Wireless pH Tester for Soil with built in specialized electrode All manuals and user guides at all guides com...

Page 2: ...oduct Please read this instruction manual carefully before using this instrument This manual will provide you with the necessary information for correct use of this instrument as well as a precise ide...

Page 3: ...s Mode 6 Bluetooth Pairing 7 Date Time 7 7 Bluetooth 7 8 Hanna Lab Application 7 Tag a Measurement 7 9 Calibration 7 Preparation Guidelines 7 Procedure 7 Stand Alone Tester Up to Three Point Calibrati...

Page 4: ...esolution pH 0 01 or 0 1 pH mV 0 1 or 1 mV Temperature 0 1 C 0 1 F Accuracy pH 0 05 pH Temperature 0 5 C 0 9 F Calibration Up to three points or four points Automatic buffer recognition with Standard...

Page 5: ...t light and fungal growth the PVDF body also has high abrasion resistance and mechanical strength The conical tip allows for easy penetration into solids and semisolids The PVDF outer junction sleeve...

Page 6: ...f old battery in accordance with local regulations 6 SETUP The Setup button is located inside the battery compartment After Setup configuration replace the cover Setup Menu Navigation Press the Setup...

Page 7: ...coverable mode it will appear in the list of Available Devices Within the application tap Connect to pair the tester with the device All readings are transmitted directly to the application Tag a Meas...

Page 8: ...y indicator disappears 7 Place the tip of the electrode in the third buffer rinse beaker then in the third calibration buffer Wait until the measurement is stored and the stability indicator disappear...

Page 9: ...ace the sleeve Ensure the o ring is fixed inside the electrode Rinse off excess gel with distilled or deionized water Shake the probe down gently to eliminate any trapped air bubbles Soak the probe in...

Page 10: ...L HI721319 Soil auger RECOMMENDATIONS FOR USERS Before using this product make sure it is entirely suitable for your specific application and for the environment in which it is used Any variation intr...

Page 11: ...ion against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accord...

Page 12: ...rld Headquarters Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com MAN9810302 Printed in ROMANIA All manuals and user guides at all guides co...

Reviews: