2

WARRANTY .................................................................................. 2
PRELIMINARY EXAMINATION ........................................................ 3
GENERAL DESCRIPTION ................................................................ 3
SPECIFICATIONS OF 

HI93501

...................................................... 4

SPECIFICATIONS OF 

HI935001 & HI935007

................................ 5

SPECIFICATIONS OF 

HI935004 & HI935008

................................ 6

OPERATIONAL GUIDE ................................................................... 7
METER SETUP ........................................................................... 11
BATTERY REPLACEMENT ............................................................. 12
TEMPERATURE PROBES .............................................................. 13

HI93501, HI935001, HI935004, HI935007

 and 

HI935008 

are

guaranteed for two years against defects in workmanship and materials

when used for their intended purpose and maintained according to

instructions. Electrodes and probes are guaranteed for six months.

 

This

warranty is limited to repair or replacement free of charge.
Damage due to accidents, misuse, tampering or lack of prescribed

maintenance is not covered.
If service is required, contact the dealer from whom you purchased the

instrument. If under warranty, report the model number, date of

purchase, serial number and the nature of the problem. If the repair is

not covered by the warranty, you will be notified of the charges

incurred. If the instrument is to be returned to Hanna Instruments,

first obtain a Returned Goods Authorization number from the Technical

Service department and then send it with shipping costs prepaid.

When shipping any instrument, make sure it is properly packed for

complete protection.

WARRANTY

TABLE OF CONTENTS

Dear Customer,
Thank you for choosing a Hanna Instruments product.
Please read this instruction manual carefully before using these instruments.
This manual will provide you with the necessary information for correct
use of these instruments, as well as a precise idea of their versatility.
If you need additional technical information, do not hesitate to e-mail
us at [email protected] or view our worldwide contact list at
www.hannainst.com.

Summary of Contents for Foodcare HI 93501

Page 1: ...1 Instruction Manual HI93501 HI935001 HI935007 HI935004 HI935008 Portable Microprocessor Thermometers w w w h a n n a i n s t c o m...

Page 2: ...If under warranty report the model number date of purchase serial number and the nature of the problem If the repair is not covered by the warranty you will be notified of the charges incurred If the...

Page 3: ...008 are pro fessional rugged and waterproof thermometers designed to be used on a daily basis in industrial kitchens and catering They provide excellent accuracy and can operate with a wide range of i...

Page 4: ...off capability Waterproof casing Range 50 0 to 150 0 C 58 0 to 302 0 F Resolution 0 1 C 0 1 F Accuracy 0 4 C 0 7 F excluding probe error Battery 3 x 1 5V AAA approx 5000 hours of continuous use Auto...

Page 5: ...nge 50 0 to 199 9 C 58 0 to 399 9 F 200 to 1350 C 400 to 2462 F Resolution 0 1 C up to 199 9 C 1 C outside 0 1 F up to 399 9 F 1 F outside Accuracy 0 2 full scale excluding probe error Battery 3 x 1 5...

Page 6: ...life indication low battery detection Auto off capability Waterproof casing Range 50 0 to 400 0 C 58 0 to 752 0 F Resolution 0 1 C 0 1 F Accuracy 0 2 full scale excluding probe error Battery 3 x 1 5V...

Page 7: ...e list of Hanna probes Note HI935007 and HI935008 has a fixed probe To switch the meter ON press the ON OFF button on the front of the meter If it does not turn on make sure that the batteries are pro...

Page 8: ...and NO PROBE message is displayed see WARNING MESSAGES section If the reading is slightly beyond the measuring range the meter flashes the closest full scale value To switch the meter OFF press the O...

Page 9: ...user to check the instrument calibration status If the meter is calibrated the display will stabilize and show 0 0 C 0 3 C in a few seconds WARNING MESSAGES NO PROBE message If the probe is not conne...

Page 10: ...more than 0 3 C then a Err message is dispayed Contact your dealer or your nearest Hanna Service Center for recalibration DAMAGED PROBE message When the readings are very far from the reading range th...

Page 11: ...ed inside the battery compartment Use the ON OFF button to switch between C or F Long press ON OFF button once to save and continue to auto off settings Use the ON OFF button to cycle through the foll...

Page 12: ...ately replace the batteries with new ones Battery replacement must only take place in a non hazardous area The batteries are accessed by opening the battery compartment cap on the back of the instrume...

Page 13: ...er without requiring recalibration Hanna probes are also available in different handle colors to avoid cross contamination during testing Note To clean the meters do not use aggressive detergents It i...

Page 14: ...instruments in residential areas could cause unacceptable interferences to radio and TV equipment requiring the operator to follow all necessary steps to correct interferences Any variation introduce...

Page 15: ...15...

Page 16: ...anna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA Technical Support for Customers Tel 800 426 6287 Fax 401 765 7575 E mail tech hannainst com www hannainst com...

Reviews: