Setting examples:

0~3599

= 0 second, the device will not wake up by itself.

3600~7199

= 3600 seconds, the device will wake up every 3600 seconds.

.RESETTING

Reset procedure clears the motion sensor's memory, including Z-Wave
network controller information. To reset Motion sensor:

1) Power on the device,
2) Press and hold the Z button for more than 20 seconds,
3)

If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which

means resetting is complete.

NOTE

Use this procedure only in the event that the network primary controller is
missing or otherwise inoperable.

.ADVANCED CONFIGURATION

Motion sensor offers a wide variety of advanced configuration settings. Below parameters can be
accessed from main controllers configuration interface.

Parameter NO. 12 MOTION SENSOR’S SENSITIVITY

The higher the value, the more sensitive the PIR sensor.

Available settings:

1-8

Default setting:

8

Parameter size:

1 [byte]

Parameter No.14 ENABLE/DISABLE BASIC SET COMMAND

Motion sensor can send BASIC SET command to nodes associated with group 2 when motion is
triggered.

0

– Disable.

1

– Enable.

Default setting:

0

Parameter size:

1 [byte]

Summary of Contents for HKZW-MS02

Page 1: ...e included and operated in any Z Wave network with other Z Wave certified devices The features list 1 Z Wave Plus certified for wide compatibility 500 serials product 2 Supports security 0 and securit...

Page 2: ...8 42MHz US 921 42MHz ANZ Range More than 100m outdoors About 30m indoors Dimensions 50mm Working current About 50mA Standby current About 20uA Recommended installation height 2m 4m INSTALLATION 1 Turn...

Page 3: ...s Should false motion alarms be reported check for any moving objects within the sensor s detection area such as trees blowing in the wind cars passing by windmills False motion alarms may be caused b...

Page 4: ...our Z Wave controller 3 Set the main controller s adding mode see the controller s manual 4 Click the Z button once or triple click the Z button quickly the LED indicator should blink fast 5 Wait for...

Page 5: ...Switch Smart Dimmer etc Motion sensor supports two association groupings Motion sensor can max associate 5 nodes in each group Group 1 reports the motion detection and battery level Group 2 is assigne...

Page 6: ...ete NOTE Use this procedure only in the event that the network primary controller is missing or otherwise inoperable ADVANCED CONFIGURATION Motion sensor offers a wide variety of advanced configuratio...

Page 7: ...the countdown being restarted Available settings 0 65535 seconds Default setting 30 seconds Parameter size 2 byte Parameter No 32 LEVEL OF LOW BATTERY Define a battery level as the low battery Availab...

Page 8: ...ion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the re...

Reviews: