background image

Summary of Contents for Smart 15 Plus

Page 1: ...Operation Manual Smart 15 Plus Micro Centifuge Where Purchased Date of Purchase...

Page 2: ...Scientific Inc If you have any questions contact our Technical Support Center 82 2 3452 8966 techsupport ihanil com www ihanil com The appearance or specifications of the device is subject to partial...

Page 3: ...Connection 9 3 4 Opening Closing the Door 9 3 5 Installing Removing the Rotor 10 3 6 Rotor ID 11 3 7 Loading Tubes 12 4 Operation 13 4 1 Control Panel 13 4 2 Setting RPM RCF 14 4 3 Setting Run Time 14...

Page 4: ...be deviced 7 The balancing work of samples should done in advance before operation 8 To ensure safe use of the device do not expose the device to strong acids strong bases cesium salt or alkaline dete...

Page 5: ...ntact your place of purchase Unusual noises or smell from the equipment Damage or wear of a power cord Breakdown of circuit breaker fuse or safety device If you spill liquid on the equipment If the eq...

Page 6: ...w ihanil com 6 21 2 Product Description 2 1 Structure Door RPM measuring window Chamber Display control panel Power Soket Power Swithch Device Power cable Operating manual T wrench 2 2 Delivery packag...

Page 7: ...ax Capacity 24 x 1 5 2 0 mL 4 PCR strips ACC DEC steps 9 10 steps Acc time to max speed 15 sec Dec time from max speed 15 sec Program memory 10 Noise level 60 dB Imbalance cutoff tracking Yes Rotor id...

Page 8: ...t due to the weight of the rotor Good ventailation For air circulation and safety maintain a 30cm clearance envelope around the centrifuge while the rotor is spinning Constant temperature humidity Cen...

Page 9: ...vice Use sockets with a protective earth conductor and provided power cord If the door is not closed the device does not operate 1 Connect the power cable to the power socket on the right side of the...

Page 10: ...e Inc Do not use scatched or cracked rotor in use 1 Before installing the rotor remove any foreign object or moisture 2 Load the rotor vertically onto the motor shaft 3 Insert the T wrench into the ce...

Page 11: ...1 Press the Setup Enter button 2 Press the Left or Right button to move the cursor for the Rotor ID setting Rotor Id Setting mode Rotor flashes on the display 3 Press the Up or Down button until the...

Page 12: ...loaded symmetrically Do not exceed the maximum rated speed of the tube Same volume of sample should be put on tubes Check symmetric loading by balncing tubes with scales 1 Check the maximum load for e...

Page 13: ...ting parameters Left Left button is used to select parameter Right Right button is used to select parameter Setup Enter Setup Enter button can be pressed to go into setup mode or complete the setting...

Page 14: ...es RCF setting mode RCF xg display flashes 3 Press Up or Down button until the required RPM RCF is displayed 4 Press the Setup Enter button 1 Press the Setup Enter button 2 Press the Left or Right but...

Page 15: ...tting mode Accel display flashes 0 Decel rate setting mode Decel display flashes 0 3 Press the Setup Enter button 4 4 Setting Acceleration Deceleration Start 1 Check all parameters are correct 2 Press...

Page 16: ...et the RPM or RCF Run time Accel Decel rate 2 Press the Left of Right button until Prog display flashes 0 You can save 10 0 9 programs 3 Press Up or Down button until the required program number is di...

Page 17: ...2 Do not use aggressive chemicals on the device such as alchol benzene acetone or phenol 3 Make sure do not scratch the surface of deivice when cleaning it Do not use a metal sponge If the device is r...

Page 18: ...losed completely Door cannot be opened Press the Door button Check the power connection Door cannot be closed Remove the dirt at the door latch and close the lid Check the lid latch is not damaged Unu...

Page 19: ...rror Motor operation error Check that the rotor is rotating through the RPM measuring window Switch power on off and re start E5 Dooropen Operating Lid open during operation Switch the device off and...

Page 20: ...can activte the emergency open manually 1 Wait for rotor to stop before activating the emergency open 2 Insert the T wrench into the emergency open hole and turn it clockwise until the door is opened...

Page 21: ...38 5 mm Max heightfortubefit 53 5mm Incl a lid 1 5 2 0 mL Micro filter tube 11 x 38 71 2 15 000 17 910 0 5mL TR0 5 8 x 37 66 15 000 16 602 0 2mL TR0 2 6 x 21 56 15 000 14 087 A2 0M 24 A2 0MP 24 Hole a...

Page 22: ......

Page 23: ......

Page 24: ...RECYCLABLE 16 Arayukro Gimpo 10136 Rep of Korea Service Inquiries 82 2 3452 8966 techsupport ihanil com www ihanil com...

Reviews: