background image

Operation Manual

HyperCOOL

HC3055 / HC3110

Product Model Name :

Date of Purchase :

Summary of Contents for HyperCOOL HC3055

Page 1: ...Operation Manual HyperCOOL HC3055 HC3110 Product Model Name Date of Purchase...

Page 2: ...ic Inc If you have any questions contact our Technical Support Center 82 2 3452 8966 techsupport ihanil com www ihanil com The appearance or specifications of the device is subject to partial change f...

Page 3: ...l Lock 9 3 2 Switching On the Device 9 3 3 HyperCOOL Connection 10 4 Operation 14 4 1 Key Functions of Control Panel 14 4 2 Display 15 4 3 Defrost 15 4 4 Vacuum 16 4 5 Time 17 4 6 Keylock 18 5 Mainten...

Page 4: ...vides information on the detailed instructions precaution troubleshooting and maintenance care Keep this manual nearby for future reference The labels on the device represent safety instructions and d...

Page 5: ...installation site should be within the rated voltage of this product If not complied the device can be damaged 4 Only use accessories manufactured by Hanil Scientific Inc Hanil Scientific Inc does no...

Page 6: ...Product Description 2 1 Product Description Back side of the device Right side of the device Vacuum Release Valve Tube Connection to Vacuum Pump Mains Inlet Power Outlet for Vacuum Pump Mains Switch...

Page 7: ...upport ihanil com 7 26 2 Product Description 2 2 Delivery Package Hyper COOL 3055 3110 AC Power Cable Hose Operation Manual Clamp Check all parts for damage that may have occurred during transportatio...

Page 8: ...Volume L 4 Trap Chamber Size x L 165 x 202 ICE Condensing Capacity kg 3 ICE Condensing Performance kg day 2 5 Compressor 1 2HP 1 2HP x 2 Refrigerant R507 R507 R1150 Power Requirement Resting VA 642 8...

Page 9: ...ng 3 Installation 3 1 Wheel Lock 1 Connect the AC power cord to the power socket on the backside of the device and put the plug into a power outlet Check the proper power and the fuse specification 2...

Page 10: ...tallation 3 3 HyperCOOL Connection HyperCOOL as a Freezer Dryer Rubber Valve Closed Tube Connection to Vacuum Pump Mains Inlet Vacuum Pump to Power Outlet Vacuum Pump to HyperCOOL Power Outlet for Vac...

Page 11: ...rain valve and the vacuum release valve are fully closed 5 Check the status of all the rubber valve handles are closed HyperCOOL as a Freezer Dryer Preparation of Vacuum Pump 1 Connect vacuum hose to...

Page 12: ...hen the vacuum pump is off While DEFROST function is activated HyperVAC the vacuum concentrator should be run at lower than 1 000 rpm not to turn on the vacuum pump Rubber Valve Closed Tube Connection...

Page 13: ...paration DEFROST should be performed only when the vacuum pump is off While DEFROST function is activated HyperVAC the vacuum concentrator should be run at lower than 1 000 rpm not to turn on the vacu...

Page 14: ...VACUUM Turning on off the vacuum pump 30 RT VACUUM inactive LED flashing 30 VACUUM activated LED flashing VACUUM ON LED ON 50 automatic pump on LED on TIME LED On TIME setting mode Set H M using the...

Page 15: ...ton is pressed Disconnect power from the pump before performing the Defrost function And vacuum release process should be followed not to allow additional moisture into chamber It can be done by openi...

Page 16: ...t turns off by pressing the VACUUM button The HyperCOOL allows air into the chamber by opening the vacuum release valve on the backside Vacuum release valve The vacuum release can be adjusted by turni...

Page 17: ...DEFROST up or VACUUM down button to up or down the value 3 Press the TIME button to fix the value 4 When the operation is completed End message comes up with beep sound At continuous running mode 0 0...

Page 18: ...t unwanted interruption of operation or change of the current setting 1 The Keylock mode is activated when the KEYLOCK button is pressed 2 The Keylock mode is deactivated by pressing KEYLOCK once agai...

Page 19: ...volatile chemicals such as alcohol benzene benzole and thinner etc 3 Be careful not to make scratches on the surface of the device Scratches may cause corrosion on the surface of the device Rusted par...

Page 20: ...t Fuse replacement may be required when the main power does not turn on by switching on the power Please follow the below instruction 1 Remove the AC power cord and open the fuse case using a screw dr...

Page 21: ...Symptom Recommended Action Power failure Make sure the AC Power cord completely connects the device to the mains outlet Check the power switch is on Refer to 3 1 Switching On the Device If it still d...

Page 22: ...l Hanil service Only HC3110model Error 5 Comp1 temperature sensor This message may come up if the temperature sensor of the compressor 1 does not normally work Turn off the main power and call Hanil s...

Page 23: ...y label 2 Use genuine Hanil Scientific Inc products and parts The best performance can be guaranteed only for the Hanil Scientific Inc approved products The customer service may not be provided for us...

Page 24: ...OOL Trap Plate for Connection Vacuum Hose to Vacuum Concentrator HHC CPP A HyperCOOL HC3055 HC3110 Trap Plate for Connection Vacuum Hose to Vacuum Concentrator with Table A GVCT MA HHC CPB HyperCOOL A...

Page 25: ...k 150 mL 45 mm FD2013 1 Freeze Drying Glass Flask 300 mL 45 mm FD2014 Freeze Drying Glass Flask 300 mL 70 mm FD2015 Freeze Drying Glass Flask 600 mL 70 mm FD2016 Freeze Drying Glass Flask 900 mL 70 mm...

Page 26: ...ith 3 Shelves Rack 4 Valves Chamber incl a Rotary Vane Pump Oil Mist Trap Connections HHC3110 HHC CPB HHC CH30 4V HHC CR25 HHC VH HVP W2V20 HVP WOF150 HHC3110 CH8VR Multi Type Freeze Drying System 110...

Page 27: ...MEMO...

Page 28: ...RECYCLABLE...

Reviews: