12
Model
RD6006-W
RD6012-W
RD6018-W
RD6024-W
RD6006P-W
RD6012P-W
Output current accuracy
±(0.5%+5 digits)
±(1‰+6 digits)
Battery voltage accuracy
±(0.5%+3 digits)
Default battery charging
cutoff current
10mA
100mA
10mA
Output ripple typical
(VPP)
100mV
250mV@6A
100mV
@12A;
150mV
@24A
20mV
②
Working temperature range
-10
℃
~40
℃
External sensor
Temperature detection
range:
-10
℃
~100
℃
/0
℉
~200
℉
External sensor
Temperature detection
accuracy:
±3
℃
/±6
℉
Constant voltage mode
response time
2ms
(
0.1A-5A Load
)
Constant voltage mode load
regulation
±(0.1%+2 digits)
Constant current mode load
regulation
±(0.1%+3 digits)
Capacity measurement
range
0-9999.99Ah
Energy measurement range
0-9999.99Wh
Capacity and energy
statistical error
±2
%
Max output voltage
(
input voltage÷1.1
)
-1
(
input voltage÷1.1
)
-2
③
Cooling fan start condition
Output
voltage>40V or
Output
current>4A or
System
temperature>45
℃
Output current>8A or
System temperature>45
℃
Output current>4A or
System temperature>50
℃
Cooling fan shut down
condition when working
Output voltage
<40V and Output
current <3.9A and
System
temperature
<45
℃
Output current <7.9A and System temperature <45
℃
Output current <3.9A and
System temperature <50
℃
Over temperature
System temperature >80
℃