background image

Remote Controller

User's Manual

HCT-2216/HCR-2216

6. OPERATING PROCESS 

6. OPERATING PROCESS 

   6-1. Starting for Transmitter and Receiver

 -. Check the condition with these steps.

     1) Open the case of the receiver and turn no the Power Switch.
     2) Pull the red EMS(Emergency Stop Switch) button at the bottom of the
        transmitter, and turn on the Key Switch to the siren('I' position).
     3) Push on each runction button th operating.

* When it pushed each button of the transmitter, the Power LED lamp blinks 3 time per

second at the Low Speed Mode, and blinks 6 times per second at the high Speed Mode.

 WARNING
 IN AN EMERGENCY, PUSH THE EMS (EMERGENCY STOP SWITCH0 BUTTON TO SHUT DOWN.

Operate after check the causes and remove them.

 Operate after check the causes and remove them.

   6-2. Operating for Transmitter and Receiver 

Check the condition to follow the steps.
If you have trouble, see 8. maintenance and fix it.
Call to us if impossible to fix it.

1 Push the ‘U’ (Up) button on the transmitter. 
2 Push the ‘D’ (Down) button on the transmitter.
3 Push the ‘S’ (South) button on the transmitter. 
4 Push the ‘N’ (North) button on the transmitter.
5 Push the ‘E’ (East) button on the transmitter.
6 P

h th ‘W’ (W

t) b tt

th t

itt

The PWR lamp (green) on the
transmitter and the Relay's lamp
in the receiver blinks.

6 Push the ‘W’ (West) button on the transmitter.

WARNING 

- Operating Only the Workers Being Trained as Operator’s Training Course. 
- Take Checkup and Training Regularly. 

B S

t O

t th Sh t

t Di t

d S

it th F i ht i L

k d i S f t

- Be Sure to Operate the Shortest Distance and See it the Freight is Locked in Safety. 
- See what the Crane and the Transmitter Move the Same Direction. 
- Never to Operate Out of Sight. (Be Sure to Operate in Sight of the Crane and the Freight.)

Hangil Control Co., Ltd

9

2008-09-24

Summary of Contents for HCR-2216

Page 1: ...ler User s Manual HCT 2216 HCR 2216 REMOTE CONTROLLER Digital Remote Control System Digital Remote Control System USER S MANUAL USER S MANUAL HCT 2216 HCR 2216 HANGIL CONTROL Co Ltd Hangil Control Co Ltd 1 2008 09 24 ...

Page 2: ...TION 2 2 FEATURES 2 3 CONFIGURATIONS 3 4 SPECIFICATIONS AND DRAWING 4 4 SPECIFICATIONS AND DRAWING 4 5 INSTALLATION AND SETUP 6 6 OPERATING PROCESS 9 7 OPERATING FLOWCHART 10 8 MAINTENANCE 11 9 TROUBLESHOOTING GUIDE 12 10 CHARGER AND BATTERY 13 Hangil Control Co Ltd 2 2008 09 24 ...

Page 3: ...er is changeable with simple action in the job site 2 2 Auto Power off Function When the transmitter is not operation more than 5 minutes power turned off to prevent discharging of the battery 2 3 Water proof Dust proof and Wide Operating Temperature Range p p p g p g This transmitter has water proof dust proof function and wide operating temperature ranges from 30 C to 70 C 2 4 Low voltage Warnin...

Page 4: ...6 1 SET Receiver HCR 2216 1 SET Receiving Antenna for 173MHz 1 EA Charger HCG 4814 1 EA Rechargeable Battery HCB 4814 1 PACK Rechargeable Battery HCB 4814 1 PACK 3 2 Spare Parts Rechargeable Battery HCB 4814 1 PACK Fuse 250V 0 5A 5 EA S 3 5 5 EA Screws 3 5 5 EA PVC Cover for Case 1 EA Hangil Control Co Ltd 4 2008 09 24 ...

Page 5: ...E FREQUENCY MSK 2400bps 1 t 21 650 MH 2 d 450 kH RF POWER RF BANDWIDTH OSCILLATION METHOD 21 Channels Frequency Separation 12 5 kHz 2nd Mix Multiplying 10 6 kHz 2 2 Stages 360 NUMBER of CHANNELS MULTIPLYING METHOD POWER AMPLIFIER EMISSION ANGLE INTERMEDIATE FREQUENCY COMMUNICATION METHOD 1st 21 650 MHz 2nd 450 kHz SIMPLEX AC250V 5A 30 C 70 C 750g 5 90kg DC4 8V PACK AC85V 264V 50 60Hz INPUT POWER N...

Page 6: ... o d u c t a f t e r P l e a s e l o o k t h r o u g h t h e c r a n e a l l t h e T i m e d u r i n g o p e r a t i o n P r e s s t h e e m e r g e n c y b u t t o n a n d p u t o f f t h e P o w e r i f t h e c r a n e i s m a l f u n c t i o n P l e a s e f i n d e l i m i n a t e t h e c a u s e o f m a l f u n c t i o n b e f o r e u s e a g a i n E M S O I S r e a d i n g t h e m a n u a l c...

Page 7: ...eiver p adjusted the same channel number according to the table as below 설정 주파수 CHANNEL NO 기기명 HCT 2216 10 1 0 173 6250 0 0 0 3 4 5 0 0 0 173 6375 173 6500 173 6625 1 2 173 6750 173 6875 0 9 A B 0 0 0 0 8 6 0 7 173 7000 173 7125 173 7250 173 7375 173 7500 173 7625 0 0 0 B C D 173 7625 14 CH TOTAL 173 7750 173 7875 NOTICE DO NOT CHANGE the RF Channel and the Address Code Switch at Site because of a...

Page 8: ... must adjust the same code between the transmitter and the receiver 10 1 CHANNEL receiver Open the case of the transmitter and the receiver see the Address Code Switch is adjusted the same position ON ON ON 1 2 3 4 1 2 3 4 1 2 3 4 100 10 1 ADDRESS Eg Refer to the settings of the Channel Switch and frequency as below ON ON ON 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 100 10 1 ADDRESS Hangil C...

Page 9: ...Transmitter and Receiver Check the condition to follow the steps If you have trouble see 8 maintenance and fix it Call to us if impossible to fix it 1 Push the U Up button on the transmitter 2 Push the D Down button on the transmitter 3 Push the S South button on the transmitter 4 Push the N North button on the transmitter 5 Push the E East button on the transmitter 6 P h th W W t b tt th t itt Th...

Page 10: ... button at the button of the transmitter and Pull the red EMS button at the button of the transmitter and turn on the Key Switch to the right PWR lamp green is Turned on Check the Siren Button Operating the Transmitter Push the red EMS button and turn off the Key Switch to the left The End of the Operating Transmitter Hangil Control Co Ltd 10 2008 09 24 ...

Page 11: ...teries 6 Contacting state of batteries 8 2 Monthly Maintenance Monthly Maintenance of the transmitter 1 Every Connectors state of every units 2 Check foreign material or dust inside the transmitter 3 Broken state of the dust proof transmitter cover 3 Broken state of the dust proof transmitter cover 4 State of the battery case 8 3 Monthly Maintenance of the receiver 1 Every Connectors state of ever...

Page 12: ...en Turn On the Power Switch Power Switch is Turned Off in the Turn On the Power Switch in the 1 PWR Lamp is Turned off but PWR Switch is Turned on Receiver Receiver Breakdown of Fuse Replace the Fuse Bad Button Replace the Button 2 Not Operating Transmitter but PWR Lamp is Turned on Bad Relay Replace the Relay Bad or Poor Connection of the Transmitter Check or Replace the Bad Parts contact failure...

Page 13: ...acks Adapter AC100V 220V 60Hz DC12V 1A 1 EA 10 3 Charge Discharge Characteristics Charging Time about 2 hours Discharge Capacity Discharge Time about 22 hours at full charging Long Service Life 300 1 000 charge discharge cycles Charging Discharging Temperature 0 C 40 C Charging Discharging Temperature 0 C 40 C 10 4 Usage of the charger 1 Contact the power to AC 220V 2 In put one battery to charger...

Reviews: