OMNICYCLE

®

 USER MANUAL 

 

COPYRIGHT 2007 - 2013, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED 

CONFIDENTIAL AND PROPRIETARY 

STANDARD LIMITED PRODUCT WARRANTY 

The warranty information provided in this section is applicable only to products purchased from ACP, 
directly or through an authorized dealer.  This section does not apply to leased products.  The terms of 
maintenance and repair of any leased products are detailed in the separately executed agreement between 
the parties. 

 

Warranty Coverage 

This warranty provides coverage, for Equipment purchased, against manufacturer’s defects in material and workmanship, 
and extends to the original owner of the product during the warranty period for that product.  Only those items returned to 
the ACP Service Center within the warranty period, and also within thirty (30) days after notification to ACP of the defect, 
shall be eligible for repair under the Standard Limited Product Warranty.  Buyer is responsible for shipping cost associated 
with sending the Equipment to the ACP Service Center.  ACP shall ship Equipment to Buyer after repair at no cost to the 
Buyer provided repair is deemed to be under warranty.   ACP may, at its discretion and only for valid warranty claim, repair 
or replace any part(s) that prove to be defective during the warranty period. 
 

Warranty Exclusion 

Any and all warranty coverage will be void if any of the following have occurred: 
 

1.

 

The product contains repairs or replacement parts not furnished by ACP. 

2.

 

The product is damaged resulting from misuse or negligence. 

3.

 

The product has been tampered with and/or altered, including serial number alteration. 

4.

 

The product was used with accessories and/or supplies, including electrodes, not approved by ACP for use with 
the product. 
 

Warranty Period 

The following coverage is provided at no additional cost to the Buyer: 

 

New Equipment / Product

.  Products purchased as new from ACP are warranted against manufacturer’s defects in 

material and workmanship for a period of one (1) year from the date of purchase. 
 

Refurbished Equipment / Product.

  Products purchased specifically as Refurbished Equipment are warranted against 

manufacturer’s defects in material and workmanship for a period of six (6) months from the date of purchase. 
 

Accessories.

  All accessories for ACP equipment / products are warranted against manufacturer’s defects in material 

and workmanship for a period of three (3) months from the date of purchase. 

 

Warranty Validation 

The following information needs to be provided to the ACP Customer Support representative prior to the product 
being returned under warranty coverage: 
 

1.

 

Buyer name or account number as it appears under the “Bill TO” on the ACP or recognized ACP Dealer invoice. 

2.

 

Invoice Date and Number. 

3.

 

Model number, description, and serial number of equipment. 

4.

 

Detailed description of the problem. 

 

Summary of Contents for ACP OMNICYCLE 01034-000

Page 1: ...nt which is incorporated by reference in its entirety This Manual may not be used for any other purpose Any additional copies of the Manual shall be ordered from ACP No changes or modifications shall be made to the Manual without prior review and written authorization from ACP No authorization is given to market sell disclose or exploit this Manual except as for purposes of using the Equipment as ...

Page 2: ...c Exercise Systems Our MEGAPULSE NEUROPROBE OMNISTIM OMNISOUND OMNIBAND OMNITEST OMNICYCLE and OMNIVR represent the most recent world wide advances available for therapeutic application of electromedical devices and other rehabilitation technology ACP is internationally recognized for its contribution to research in the development of medical applications for therapeutic rehabilitation The Company...

Page 3: ...ND PRINCIPLES OF USE 15 Definitions 15 Universal Precautions Body Substance Isolation 15 Cleaning Disinfecting of the Omnicycle 15 Cleaning and Low Level Disinfection 15 Intermediate Level Disinfection and Barriers 15 Use of Barriers Intermediate Level Disinfection 16 OMNICYCLE PROGRAM MENU 17 Full Program Menu 18 Description of Omnicycle Functions 18 TROUBLESHOOTING 23 Preventive Maintenance and ...

Page 4: ...OMNICYCLE USER MANUAL COPYRIGHT 2007 2013 ACCELERATED CARE PLUS CORP ALL RIGHTS RESERVED CONFIDENTIAL AND PROPRIETARY ...

Page 5: ... possible the wheelchair footrests should be removed The feet are fixed in the Omnicycle footrests and may be further secured by the calf supports optional feature or the foot retainer pads optional feature The Omnicycle is then started from the control panel Using the Omnicycle as an upper body exerciser The patient sits on a chair or wheel chair The Omnicycle stands on the floor in front of the ...

Page 6: ...n be gained during the treatment The Omnicycle is designed to be used in a sitting position only Never stand on the foot rests with the full weight of your body The feet must not be placed in the foot rests during an upper body exercising session The greater the distance between the Omnicycle and the patient s seat wheelchair the more the knee hip and UE joints are placed in extension Start at a c...

Page 7: ...not suitable for moving the unit over uneven surfaces The Omnicycle must be carried up or down stairs or steps This requires at least two persons Switching the Omnicycle On Off If the screen is not illuminated the Omnicycle is in stand by mode Press any button to switch the Omnicycle to normal operating mode The screen will light up and following a self test lasting about 5 sec the Omnicycle is re...

Page 8: ...upper body exerciser D Locking screw with knurled knob for adjusting reach of upper body exerciser E Locking screw with knurled knob for adjusting height of handlebar upper body exerciser F Calf support G Footrest H Crank with variable length settings I Omnicycle stand with transport wheels J Transport wheels K Control panel inclination adjuster L USB interface for control panel A B E J I K H G C ...

Page 9: ...h lasts about five 5 seconds the welcome screen is displayed followed by the system version screen After the self test the unit will display the following start screen The Omnicycle is now ready for use Pressing the START button at this point will start the exercise session with the basic default settings with the pedals going at 10 rpm in assisted exercise mode When the patient pedals at a higher...

Page 10: ... it is easy to put the patient s feet in place Push the Assisted Entry button and wait until the footrest has rotated to its lowest position then place the foot Repeat for the other foot Secure the calf support belts when the foot is in the upper position Next fit the patient and check clearances In cases of contracture or in order to limit joint movement adjust the LE pedal length This can be don...

Page 11: ...e sure the handles are securely in place before use Use optional armrests for patients with limited mobility Make sure the patient s arms are comfortably secured Setting up the Exercise Program Upper Extremity Ensure that the patient can comfortably grip the handle Use the optional armrest pictured above for patients with limited mobility Make sure the patient s arms are comfortably secured To cha...

Page 12: ... may need to be increased When first switched on the Omnicycle always starts with an assisted exercising phase with a preset resistance and speed When the patient starts actively exercising with the same motion the Omnicycle automatically changes over to active exercising mode Active exercising means that the patient uses his her own efforts and energy to turn the machine s cranks against a set re...

Page 13: ...ends on the preset motor power and has a maximum level of 22 Nm The resistance can be increased by pressing the button To increase the resistance one increment at a time press and release the button The resistance can be reduced by pressing the button and has a minimum setting of zero If you press and hold the or button the setting increases decreases continuously up down to the maximum minimum Th...

Page 14: ...g an exercising session by pressing the button next to the symbol The current direction of rotation is indicated by the solid arrow Pressing the button reverses the direction of rotation A change of direction is always performed with a smooth transition All other parameters speed motor power arm leg exerciser spasticity detection remain the same J Speed when exercising actively this shows the actu...

Page 15: ...nd press it against the Velcro strip Before every exercising session check that your feet are correctly positioned in the footrests and are securely held by the Velcro straps Adjusting Crank Length Adjustable Cranks The Omnicycle has been fitted with adjustable cranks Thus the degree of movement can be adjusted individually to suit each patient s mobility Switch off the Omnicycle by pressing the S...

Page 16: ...he fixing screws Tip the Omnicycle forwards again into its normal position To level the Omnicycle on an uneven floor the rubber feet on the exerciser stand can be adjusted Undo the lock nut with an open ended spanner size 0 5 inches and unscrew the rubber foot until the Omnicycle stands firmly Retighten the lock nut 34 Adjusting the Upper Body Exerciser The upper body exerciser for the Omnicycle c...

Page 17: ... exercising handle and pull the exercising handle off the spindle Press in the locating pin on the adapter handle and slide it onto the spindle on the crank Release the locating pin and push the adapter handle as far as the stop The locating pin should audibly snap into position The adapter handles are not designed to support the full weight of the body or for carrying the Omnicycle 35 Adjusting t...

Page 18: ...e a gap of at least 3 meters between exercisers A simple test can be performed to check that the heart rate sensor is functioning properly The screen will show a green heart symbol and a heart rate if the signals from the heart rate sensor are sufficiently strong and regular If there is no heart rate signal the heart symbol is grey A weak irregular heart rate signal is indicated by an orange heart...

Page 19: ...ecommends the following guidelines Cleaning and Low Level Disinfection This is a recommended daily housekeeping practice to keep the equipment clean and free of contaminants which could contribute to transmission of infection The following practices are recommended for use when treating intact skin without the presence of physiologic fluids such as blood and urine Clean equipment daily with ACP ge...

Page 20: ...contamination Barrier film is for single use only The film is discarded after each patient therapy The procedure for use is as follows 1 Wash hands 2 Apply Intermediate Level Disinfection prior to barrier application 3 Select tear or cut with clean scissors a length of barrier film to fit over the operator surfaces of the Omnicycle unit 4 Prepare any items which may become in contact with the ther...

Page 21: ...ire entry of an amount e g motor power this button increases the setting B X Cancel Discard changes This button takes you back up to the next higher menu level Any changes previously saved by pressing Save Changes button are retained those not saved by pressing Save Changes are lost C Save Changes Continue This button saves your settings If the menu item selected has further options this button ta...

Page 22: ... CARDIO Duration 1 to 60 minutes 15 minutes Biofeedback Symmetry bars road Assisted Off Symmetry bar Motor power 2 to 22 Nm 15 Nm Pulse demand 60 to 160 bpm 120 bpm SYSTEM Sensitivity mike 1 to 10 2 Language Multiple Languages English Contrast 1 to 40 15 Description of Omnicycle Functions The first menu level comprises the following items Neuro Ortho Cardio System Technical Neuro basic setting Exe...

Page 23: ...een the two sides The total of the two bars always adds up to 100 These modes are used to retrain Right Left function motor control and symmetry With the road diagram a bicycle moves to the left or right on the road according to distribution of power output between the left and right sides In addition the pedaling speed is indicated is indicated by the speed at which the dotted line down the middl...

Page 24: ...specify the threshold at which the Omnicycle sensors detect a spastic reaction on the part of the patient and stops the motor to minimize the risk of overstressing the patient Select the setting for patients subject to spasms as follows Fine for patients with very sensitive joints and tendons At this setting even very slight resistance is enough to stop the motor Medium for patients with less sens...

Page 25: ...btained The function operates according to the principle of as much assistance as necessary but as little assistance as possible The intention is to strengthen the patient s efforts at all times In the case of leg amputee patients the Muscle assistance function performs the work of the inactive side In such cases the Muscle assistance function operates like an electronic flywheel 44 Microphone sen...

Page 26: ...essing the STOP or START button takes you back to the basic display 45 Resetting the Basic Exercise Settings and Defaults When the Omnicycle leaves the factory it is programmed with the basic settings If any settings are changed on the submenu those changes are retained even if the power is switched off or disconnected That means that the same settings can be used for the next exercising session I...

Page 27: ...crank length on both sides Check that sitting position is central relative to spindle The Omnicycle does not start Have you pressed START twice if Omnicycle is in stand by mode Check power cord Unplug the power cord then reconnect Check power supply fuse Select the correct exerciser upper or lower body Unlock the upper body exerciser Exercise session analysis is not displayed Exercise for at least...

Page 28: ...trol cables are properly routed and are not in danger of being snagged pulled by the lower or upper cycle operation When moving the cycle always make sure the power cord is unplugged and use the build in straps to move the unit on its wheels Always keep the system clean and keep any debris such as paper string cloth or clothing away from the cycle moving parts Service Center For repair or service ...

Page 29: ...ds Crank Length Fixed Variable 3 0 inches 4 3 inches 2 5 4 5 inches Speed Range 0 60 rpm Torque Range 2 22 Nm Power Supply 110 V 60 Hz Power Consumption 160 VA Fuse 2 X 1 6 A slow Noise Emission Lpa 70 dB Ambient conditions for operation 10 ºC to 35 ºC 0 to 90 Rh 970 to 1030 hPa Ambient conditions for storage or transportation 30 ºC to 65 ºC 0 to 90 Rh 970 to 1030 hPa ACP reserves the right to cha...

Page 30: ...remity and Upper Extremity rehabilitation and exercise options Biofeedback training and Spasticity detection with color display screen Shipping Weight 100 lbs 45 kg ITEM ITEM NO DESCRIPTION 51123 Glove attachment 39222 Cardio Pulse Set with transmitter receiver coiled cord and straps T34 60239 Molded arm rest attachment Left 54565 Molded arm rest attachment Right 29518 Omnicycle Operator Manual Th...

Page 31: ...Control 4 x 6 perforated sheets 1200 sheets roll 66431 Barrier Film for Surfaces Infection Control 6 x 9 perforated Sheets 1200 sheets roll 50593 Barrier Film for Surfaces Infection Control 12 x 14 perforated Sheets 800 sheets roll 63574 Barrier Film 3 Tubing 1200 roll 55536 Super Sani Cloth Wipes Single Use Packets 50 pkt bx 44425 Super Sani Cloth Wipes Tub 160 Tub 96849 Sani Cloth Wipes w Bleach...

Page 32: ...lusion Any and all warranty coverage will be void if any of the following have occurred 1 The product contains repairs or replacement parts not furnished by ACP 2 The product is damaged resulting from misuse or negligence 3 The product has been tampered with and or altered including serial number alteration 4 The product was used with accessories and or supplies including electrodes not approved b...

Page 33: ...hipping charges and related costs to return the unit to the customer provided repair is deemed to be under warranty ACP is not responsible for any loss or damage to the Equipment prior to receipt at the ACP Service Center Equipment returned for warranty service must be shipped complete with all accessories except for manuals in its original packing or equivalent so as not to be damaged while in tr...

Page 34: ...self test which lasts about five 5 seconds the welcome screen is displayed followed by the system version screen After the self test the unit will display the following start screen The Omnicycle is now ready for use Pressing the START button at this point will start the exercise session with the basic default settings with the pedals going at 10 rpm in assisted exercise mode By actively turning t...

Page 35: ...le has started the exercise session the following screen will be displayed The DURATION will display the time remaining in the started exercise session and will count down to zero at which time the cycle will sound an audible tone and stop The exercise session activity report screen will be displayed 1 0 Pulse 0 1 min Duration 14 21 min Distance 0 0 km Power 0 Watt ...

Page 36: ...meters for selected programs SELECTING PROGRAM The Omnicycle has a number of exercising programs that are based on the needs of a typical patient group For each patient group the exercising parameters can be selected and set on the submenu To enter the submenu from the main start up screen press the two minus sign buttons at the same time 1 0 Pulse 0 1 min Duration 15 00 min Distance 0 0 km Power ...

Page 37: ...ng screen will be displayed Pressing the UP or DOWN arrows will scroll the screen thru the available main programs Neuro Ortho Cardio and System To select the desired program press the CHECK MARK button when that programs appears in the screen center and is identified by the black color of the program name box Ortho Neuro Selection ...

Page 38: ...M In the example below the Cardio program was selected The following screen will be displayed The following choices are then available for the Cardio program Duration Biofeedback Motor Power and Pulse Demand Press the CHECK MARK button to select the option In this example the DURATION was selected The following screen will be displayed Biofeedback Duration Cardio ...

Page 39: ...essing the UP or DOWN arrows Press the CHECK MARK button to select the value for that parameter At this point that value will be saved and the screen will display the previous available menu for the Cardio program NOTE Pressing the X button will return the user to the previous menu without making a selection from the current screen 16 min 15 min 14 min Selection ...

Page 40: ... analysis data Also when the exercise session is completed and the session time expires the exercise session analysis data is displayed automatically The following screen will be displayed If display time for this screen ends and the screen reverts to the start up screen by pressing the STOP button one time the activity report will be displayed again Report Motor Power End 4 4 Nm Motor Power Begin...

Page 41: ......

Page 42: ......

Reviews: