background image

 

2.3. Factory Settings 

The following are the factory settings of COM port. You can change the factory settings of COM 

port with commands. In this case, you have to remember the changed factory settings. 

 

Baud rate: 9600 bps 

 

Data Bit: 8 bit 

 

Parity Bit: No parity 

 

Stop Bit: 1 stop bit 

 

Flow control: None 

2.4. Status LED 

There are two LED on HPS-110. 

 

PWR (Green): It is an indication of power on/off status. 

 

LNK  (Green):  When  a  wireless  link  is  on,  it  is  turned  on.  If  HPS-110  is  in  the 

configuration mode, it will be flashing every second. 

2.5. Reset Button 

The RST button has the following functions. 

 

Enter / Exit the configuration mode 

 

Restore the factory settings

1

 

 

Disconnect and reconnect a wireless connection. 

2.5.1.  Entering the Configuration Mode 

When the LNK LED is OFF, push the RST button. When the LNK LED is ON, you have to push 

the  RST  button  twice  to  enter  the  configuration  mode.  If  you  enter  the  configuration  mode 

successfully, LNK LED will be flashing every second. And HPS-110 COM port will be stored the 

factory settings. 

2.5.2.  Exiting the Configuration Mode 

You can have two options to exit the configuration mode. 

 

Exit the configuration mode by software: Type 

“X”. 

 

Exit the configuration mode by the RST button: Push the RST button. 

2.5.3.  Re-connection 

When the LNK LED is on, you can push the RST button to disconnect and reconnect a wireless 

link. 

 

                                                   

1

  If you push the RST button, the COM port of HPS-110 will be stored the factory settings.

 

Summary of Contents for HandyPort-Serial

Page 1: ...HPS 110 HandyPort Serial Wireless Solutions in your Hand User s Manual Version 2 1...

Page 2: ...s 5 2 3 FACTORY SETTINGS 6 2 4 STATUS LED 6 2 5 RESET BUTTON 6 2 5 1 Entering the Configuration Mode 6 2 5 2 Exiting the Configuration Mode 6 2 5 3 Re connection 6 3 USAGE 7 3 1 HARDWARE INSTALLATION...

Page 3: ...oth Serial Port Profile and Generic Access Profile No need of external host and software Easy of installation and use Supports configuration of the local device Supports configuration of the remote de...

Page 4: ...Wire to Board Connector Angle Type 4 Pin Male1 Frequency 2 400 2 4835GHz Tx Power Max 20 Typical 16dBm Rx Sensitivity 84dBm Antenna Interface SMA Female Antenna Gain Max 2dBi Power Supply 3 3 16VDC Cu...

Page 5: ...e RST Reset Button GND Signal Ground RXD RS 232 Received Data TXD RS 232 Transmitted Data VCC System Power 2 2 2 RS 232 Signals Pin Number Notation Direction Description 1 VCC Input Vcc 3 3V 16V 2 TxD...

Page 6: ...e Restore the factory settings1 Disconnect and reconnect a wireless connection 2 5 1 Entering the Configuration Mode When the LNK LED is OFF push the RST button When the LNK LED is ON you have to push...

Page 7: ...on Step 2 Open a Hyper Terminal and set it up Step 3 Push the RST button on HPS 110 If you enter the configuration mode successfully LNK LED will be flashing every second Step 4 Hit the Enter key 5 s...

Page 8: ...rs Paired adapters should have a same PIN code 5 Search timer GTO CR Set a search timeout TO timeout ASCII 0 999 Connection mode 3 only Default 10 sec 6 Max number of search HNO CR Set the max number...

Page 9: ...nect TAddr TO CR Try to make a connection Addr a remote address TO option ASCII 0 999 Connection mode 3 only ASCII 0x2C Default Timeout 10 sec 16 Cancel U Cancel a command Connection mode 3 only 17 Vi...

Reviews: