Description of Function
14 / 36
DOUBLE-SEAT VALVE INOVA (Type 580)
BA 058000.06 EN
15.11.2018
4.1.1
Process Integration, Mechanical
Four standard housing executions are offered for the integration of the double-seat valves
in the piping system (standard execution in bold print). The other housing executions are
available on request.
03
Fig. 2: Form of execution
A
Form II (e.g. execution 58001-II)
B
Form X (e.g. execution 58004-X)
Note
In the housing form
X
the line-evens are moved by 90°; in the housing execution
II
these run
parallel to each other. The broad line in the symbol display indicates the upper line-even.
Order No.
Execution X
Order No.
Execution II
58001 / 58061
58001 / 58061
58002 / 58062
58002 / 58062
58003 / 58063
58003 / 58063
58004 / 58864
58004 / 58864
4.1.2
Process Integration, Electrical
There are various control units available for the integration of the double-seat valves in the
automated production CIP process:
Types
Valve position
Control valves
BUS system
S
1/2
--
S0 / S0-A
1/2
0/3
ASI
S3 / S3-A
2
3
ASI
•
Proximity switch for position (S)
•
Control unit for position and function check (SO)
•
Control unit for switching, position and function check (S3)
A
B