5.2 Ttroubleshooting Principle 

 

WARNING     

 

 

 

There are extremely dangerous voltage and power levels present inside this unit. Do not attempt to 

diagnose or repair unless you have had training in power electronics measurement and 

troubleshooting techniques. 

 

A.  The cutting torch fails to ignite the arc when torch trigger depressed, DC pilot light on.                                             

1. Gas pressure too high, gas test then adjust gas pressure 60 psi (to 4.2 bar). 

B. The cutting torch fails to ignite the arc, when torch trigger depressed, torch/air pilot light flashes.                                             

1. The shield cup improper installation, turn off the power source, install and screw it down properly, then turn 

on the power source. 

C. The cutting torch fails to ignite the arc, when torch trigger depressed, DC pilot light ON and air 

flows

 

intermittently. 

1.The electrode or nozzle improper installation, turn off the power source, install the electrode or nozzle, and 

screw shield

 

cup down properly, then turn on the power source.   

D .The cutting torch fail to ignite the arc, when torch trigger depressed, DC pilot light ON and air 

flows

 

intermittently. 

1. Short-circuit for burned-out and other abnormal situation, turn off the power source to change the 

electrode and nozzle. 

E. Power lamp and temperature lamp ON. 

1.      Air flow blocked, check for blocked air flow around the unit and correct condition. 

2.      Fan blocked, check and correct condition. 

3.      Unit is overheated, let unit cool down for at least 5 minutes. Make sure the unit has not been operated 

beyond Duty Cycle limit, refer to technology parameters in Section 2. 

4.      Faulty components in unit, return for repair or have qualified technician repair per Service Manual. 

F. Torch fails to ignite the arc when torch switch is activated 

1.      System is in SET mode. Change to RUN mode. 

2.      Faulty torch parts, inspect torch parts and replace if necessary. 

3.      Gas pressure too high or too low, adjust to proper pressure. 

 

 

   

 

 

 

Summary of Contents for HSP60

Page 1: ...Read this Owner s Manual Completely before attempting to use this equipment Save this manual and keep it handy for quick reference Pay particular attention to the safety instructions we have provided...

Page 2: ...NECTIONS 3 3 3 INPUT POWER CONNECTIONS 4 3 4 INPUT GAS CONNECTIONS 4 4 OPERATION 5 4 1 LAYOUT FOR THE FRONT REAR PANEL 5 4 2 CUTTING PREPARATION 6 4 3CUTTING OPERATION 6 5 MAINTENANCE 7 5 1 CUTTING TO...

Page 3: ...and gases from the plasma arc depend on the kind of metal being used coatings on the metal and the different processes You must be very careful when cutting or cutting any metals which may contain on...

Page 4: ...en gas can be eliminated or dissipated Trapped hydrogen gas that is ignited will cause an explosion NOISE Noise can cause permanent hearing loss Plasma arc processes can cause noise levels to exceed s...

Page 5: ...on class H Net weight kg 22 9 Cooling method AF Note The above parameters are subject to change with the improvement of machines 3 Installation 3 1 Unpacking Identify and account for each item per the...

Page 6: ...illuminate alarm light and current will be cut off If the power supply voltage continually goes beyond the safe work voltage range it will shorten the life of the machine If this occurs the below meas...

Page 7: ...s insufficient air pressure Below 50 Psi 5 Ready DC Indicator Indicator is ON when DC output is active trigger is depressed 6 RUN SET Power ON in RUN Change to SET for 10 sec air purge Change to RUN t...

Page 8: ...when cutting release torch trigger and allow unit to cool until the alarm resets and lamp goes OFF then press on the switch to start cutting again 2 In the automatic air purge mode SET pressing trigge...

Page 9: ...swirl ring by lifting off electrode and place both on bench 4 Locate electrode wrench and remove electrode by rotating counter clockwise RH thread 5 Inspect torch head for clogged air ports or damage...

Page 10: ...ff the power source install the electrode or nozzle and screw shield cup down properly then turn on the power source D The cutting torch fail to ignite the arc when torch trigger depressed DC pilot li...

Page 11: ...hnician repair L Torch cuts but low quality 1 Current A control set too low increase current setting 2 Torch is being moved too fast across work piece reduce cutting speed 3 Excessive oil or moisture...

Page 12: ...10 5 4 Electrical principle drawing...

Page 13: ...10 H S AUTOSHOT SERVICE 888 677 3798...