background image

Marinator MCR011

Troubleshooting

Problem

Possible Cause

Possible Solution

Marinator does not heat

1. No power at receptacle
2. Power switch not ON
3. Marinator not fully plugged into receptacle

1.

Check receptacle power

2.

Turn power on

3.

Plug the Marinator cord into 120V 15A 
receptacle

Control display on (no heat)

1. Control not set high enough

1. Set the control temperature higher

Power switch ON and 
control display on (no heat)

1. Defective heater
2. Defective control

1. Call H&K Customer Service at 1800-788-
2445

Control cycle on and off

1. No water in Marinator
2. High limit switch turning unit on and off

1. Carefully add water to fill line

Pan floating in water

1. Too much water in the Marinator

1. Carefully scoop water out with a coffee cup 
until water level comes down to water fill line 
stamped in each end of the Marinator

Revision (B)

Summary of Contents for MCR011

Page 1: ...McDonald s Systems Inc Manufactured by H K International 2200 Skyline Drive Mesquite TX 75149 U S A Telephone 214 818 3500 Fax 214 818 3596 Distributed by H K International 2200 Skyline Drive Mesquit...

Page 2: ...ion Page Warnings 3 Introduction 3 Warranty 4 Service Information 4 Power Requirements 5 Initial Setup 5 Calibration Check 5 Operation Procedures 5 Parts Description 6 Wiring diagram 7 Troubleshooting...

Page 3: ...vel line and turned ON to preheat for 60 minutes prior to loading with product Revision B STORE MANAGERS DO NOT SUBMERGE MARINATOR IN WATER IF UNIT IS SUBMERGED IN WATER YOUR WARRANTY WILL BE VOIDED D...

Page 4: ...purchaser H K shall not be liable for loss damages or expenses arising from misuse abuse alteration accident or improper installation of the refrigerator such as Improper or unauthorized repair Failur...

Page 5: ...the thermostat will need to be adjusted CAUTION Equipment and water contents are hot Use breakfast cart to transport the Marinator to the sink area NOTE Use necessary precautions such as gloves to ha...

Page 6: ...R SWITCH E 1 19 1 3 FUSE LITTLEFUSE 326002P 2AMP E 3 21 7 4 FUSEHOLDER E 3 23 2CS 5 SWITCH HI LIMIT PB 3L11220 E 5 117 6 HEYCO 1311 CLEAR WINDOW PLUG E 8 32 2 7 STRAIN RELIEF E 8 44 1 8 FOIL HTR 8 1 2...

Page 7: ...Marinator MCR011 Schematic Revision B...

Page 8: ...ol not set high enough 1 Set the control temperature higher Power switch ON and control display on no heat 1 Defective heater 2 Defective control 1 Call H K Customer Service at 1800 788 2445 Control c...

Page 9: ...d licensed technician should perform all service and repair WARNING If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person in order to av...