background image

 

 

 CS-684 operation manual

 

 

 

issue 1 16.08.02                                                                                                               

                        P.13 of 13

 

Trouble Shooting

 

 
 

Problem 

Cause 

solution 

No power to 

individual parts 

Fault with power cord or plug 

Check the power connection 

Circuit breaker tripped 

Reset the breaker and investigate the 
system 

Main power supply not switch on 

Switch on the main power supply 

Bad contact 

Check the circuit if there is any loosen 
part 

Transformer fault 

Check the voltage of power supply 

Temperature monitor 

unsteady 

Thermocouple fault 

Replace the temperature sensor 

Thermocouple connection is loosen 

Check and tighten the connection 

Temperature controller malfunction 

Replace the circuit board in the control 
box 

Thermocouple extension cable short 
circuit 

Check the break point and repair 

Thermocouple installed in wrong 
position 

Check the end point of the sensor and 
relocate the position of it 

Temperature monitor 

showing the ambient 

temperature 

Heater not started up 

Press the heat button 

Thermocouple fault 

Replace the thermocouple 

Power supply voltage unsteady 

Install voltage stabilizer 

Heater temperature 

cannot raises up 

Solid state relay (SSR) malfunction 

Replace the SSR 

Compressed air pressure too low and 
interlocked 

Increase the compressed air pressure 

 

Summary of Contents for CS-684

Page 1: ...e service hh com hk t 852 24813068 f 852 24813727 Room 1117 11 F Asia Trade Centre 79 Lei Muk Road Kwai Chung N T Hong Kong CS 684 Pneumatic Flat Press Machine Operation Manual is powered by H H Asia...

Page 2: ...duction 5 Specifications 6 Machine Components 7 Control Console 8 Preparation Before Main Power Connected 9 Operation Mode 9 Machine Operation 10 Machine Setting 11 Control Panel 11 Control Panel Gene...

Page 3: ...regard to Safety Please observe these safety tips for safe efficient an injury free operation of your equipment By strictly following all instruction contained in this manual you will certainly obtai...

Page 4: ...CS 684 operation manual issue 1 16 08 02 P 3 of 13 Precautions with regard to Safety cont...

Page 5: ...CS 684 operation manual issue 1 16 08 02 P 4 of 13 Name Plate...

Page 6: ...r processing the flat press products in the market today Built on digital control platform and designed for the professional users Operators are recommended to have basic knowledge and skill in heat p...

Page 7: ...n 400 W Compressed Air 0 4 Mpa Heat Temperature Range Room Temperature 260 Press Duration 1 999 second minute or hour Heat Press Size 110mm x 110mm Lower Platform Size 100 Overall Dimensions 300mm L x...

Page 8: ...mponents 2 1 3 4 7 5 8 9 10 11 6 1 heating plate pressing head 2 safety protective bar 3 lower platform 4 machine pedestal 5 stop cancel button 6 control console 7 frame 8 compress air filter regulato...

Page 9: ...CS 684 operation manual issue 1 16 08 02 P 8 of 13 Control Console 1 Power Switich On Off the Power 2 Heater Switch On Off the Heater 3 Control Panel Set the heat temperature setting press time 2 3 1...

Page 10: ...h plug is located at the back of the machine plug into the main power supply socket 3 Foot switch connection The foot switch socket is located at the back of the machine plug in the foot switch connec...

Page 11: ...e the cloth on the working table and step on the left foot switch once the heating plate will goes down The timer will be triggered simultaneously After the countdown finished the heating plate will g...

Page 12: ...rol Panel 1 PV Field processing temperature 2 SV Set target temperature 3 SET Select different settings 4 OUT1 decrease the set point 5 OUT2 increase the set point Control Panel General Display Genera...

Page 13: ...tting below 260 as a higher temperature will decrease the life span of the machine Press Timer Adjustment Press the SET button once again the display will alike the below diagram PV will show with St...

Page 14: ...Thermocouple connection is loosen Check and tighten the connection Temperature controller malfunction Replace the circuit board in the control box Thermocouple extension cable short circuit Check the...

Reviews: