background image

Appendix A 

A-7 

Bar Code Command Menu 

Option Code : “0 – 9”, “A – F” 

System Command 

           

                                                   

 

                 

0

                                                               

8

 

                                         

                                                     

 

                                               

4

                                                                 

C

 

           

                                                   

 

                 

1

                                                               

9

 

                                         

                                                     

 

                                               

5

                                                                 

D

 

           

                                                   

 

                 

2

                                                               

A

 

                                         

                                                     

 

 

                                             

6

                                                                 

E

 

           

                                                   

 

                 

3

                                                               

B

 

                                         

                                                     

 

 

                                             

7

                                                                 

F

 

                 

 

             

FIN (Finish) 

 

                 

 

               

END (Exit) 

 
             

(

System List) 

                 

 

                 

SYSLIST 

 
         

   

(Master Default) 

                 

 

             

M_DEFAULT 

 

 

Summary of Contents for Imageteam 3220

Page 1: ......

Page 2: ...tment on the part of HHP HHP shall not be liable for technical or editorial errors or commissions contained herein not for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into...

Page 3: ...he interference at his own expense Caution Any changes or modifications made to this device that are not expressly approved by Hand Held Products Inc may void the user s authority to operate the equipment Note To maintain compliance with FCC Rules and Regulations cables connected to this device must be shielded cables in which the cable shield wire s have been grounded tied to the connector shell ...

Page 4: ...ii ...

Page 5: ...ogy Programming 3 11 Keyboard Interface Control 3 21 Serial Interface Control 3 24 Wand Emulation Control 3 26 Operating Control 3 27 Condensed Editor 3 32 Chapter 4 Customer Service Main Office 4 1 United Kingdom Office 4 1 Asia Pacific Office 4 2 Japan Office 4 2 Latin America Office 4 2 Application Support 4 2 Chapter 5 Limited Warranty Appendix A Interface Cable Converters A 1 Beeping Indicati...

Page 6: ...iv ...

Page 7: ...ls and PCs for point of sale or general purpose applications Both the VT3060B and VT3080B have Flash Memory are compact in size are comfortable to use and have been designed to take the punishment of daily use About This Manual This User s Guide provides installation and programming instructions for both the IT3220 and the VT3060B 3080B Customer support and warranty information is also included HH...

Page 8: ...on P N 3220 12MDKIT S N A1210001 Made in Taiwan IMAGETEAM MID RANGE LINEAR IMAGER PS 2 KB WEDGE KIT Complies with FCC Part 15 and Canadian ICES 003 Emission requirements See User s Manual for details P N 3220 12 S N A1210001 N344 Made in Taiwan N344 Hand Held Products Inc www hhp com Model Number Serial Number Outer Box Label Product Label Description P N 3220 12MDKIT S N A1210001 Made in Taiwan I...

Page 9: ...at has been designed to operate under Microsoft Windows 95 98 Windows NT and Windows 2000 and provides the following functions User friendly on screen configuration Configuration download and upload Program Firmware field upgrade Check software revision Full feature data editor To use the HHP SET with the IT3220 the user must have a serial adapter cable and a power supply Please refer to Chapter 3...

Page 10: ...Getting Started 1 4 ...

Page 11: ... PC AT PS 2 Keyboard Wedge interface If you need to change the host interface please refer to the Host Interface Selection described in Chapter 3 to find your desired interface The following paragraphs provide the installation of the most popular host interfaces Keyboard Wedge Interface The keyboard wedge interface allows data transmission from the scanner to the host through the existing keyboard...

Page 12: ...C AT Keyboard Wedge Connection PS 2 Keyboard Wedge Connection Plug the 5P DIN female connector of the slave cable into the 5P DIN male connector of the main cable of the scanner Then connect the rest of the connectors to the computer keyboard port and PS 2 keyboard PC AT Keyboard Wedge Connection Plug the 6P Mini DIN male connector of slave cable into 6P Mini DIN female connector of the main cable...

Page 13: ... Serial Interface bar code to configure the scanner to perform the RS 232 serial interface operation RS 232 Serial Interface Scanning the RS 232 interface bar code above configures the scanner s serial parameters to 9600 Baud 8 data bits no parity and 1 stop bit no handshaking Please note that the RS 232 settings of the host system must match the scanner s RS 232 settings If you are in the Windows...

Page 14: ... 5 0 and Windows 2000 or above Plug the RJ45 phone plug of the scanner main cable into the USB keyboard cable converter Plug the 4 pin USB Type A connector into the desired USB port of your computer You will hear the power on beep twice to signal that the power on routine of the scanner is completed Whenever the scanner s USB interface scanner is connected to any computer system for the first time...

Page 15: ...enu is designed for field programming convenience Before you use the bar code programming menu please take the time to review the command structure and various programming procedures HHP SET The innovative HHP SET utility provides the following features User Friendly On screen Configuration Configuration Download and Upload Program Firmware Field Upgrade Flash Check Software Revision Full featured...

Page 16: ...anner The Save feature allows the configuration to be saved as a file The Convert feature consolidates all programmable parameters for a certain application and prints the configuration list Configuration Download and Upload You can retrieve Upload the configurations from the scanner or send Download new configurations to the scanner Of course duplicating preset configurations is as easy as 1 2 3 ...

Page 17: ...the following functionality General Transmission Control The available parameters include Preamble Postamble Suffix Symbol ID and Data Length Transmission and Transmission Time Control Advanced Data Verification The user can base the specific data format on the desired Bar Code Symbologies to select Valid ASCII Domain Valid Data Length Domain and Matched Data Value to establish any desired filteri...

Page 18: ...he output sequence should be unit price 76 date code 1025 and serial number 123456 Actual Bar Code label 9 9 1 0 2 5 1 2 3 4 5 6 9 8 7 6 Desired Output 76 TAB AA1025 TAB S N 123456 TAB Please use HHP SET to configure the full feature Data Editor and follow the procedures listed below Configuration Procedure Disable Data Editor Pass Control no check in box Disable Select Using 1 Rule Set Applied Ba...

Page 19: ...e Scanner 3 5 Set Added Field to Insert 3 Added Fields Set AF1 Added Field 1 to AA Set AF2 to S N Set AF3 to TAB Hex 09 Set Transmission Sequence user defined transmission sequence to LF AF3 AF1 F2 AF3 AF2 F3 and AF3 ...

Page 20: ...listing system information SYSLIST recovering to factory preset configurations M_DEFAULT and so on Please note that all system commands will take a few seconds to complete the operations The user must wait for the completion beeps before scanning another bar code Family Code The Family Code is scanned to select the user desired programming family More than one hundred programming families have bee...

Page 21: ... 4 seconds to store parameters in internal Flash Memory ASIC or non volatile memory after you scan the END Please do not turn off the power before the completion beep It may destroy all configured parameters System List Master Default Scan M_DEFAULT Scanner returns all programmable parameters to factory preset configurations then issues the completion beep 3 short beeps Scan SYSLIST Scanner lists ...

Page 22: ...an One of Option Codes Repeat Selection Scan END No Yes Scan FIN If indicated EXAMPLE 2 Enter programming mode Select one of desired programming families Select several option codes of desired parameters 1 Select one or several option codes 2 If it s necessary scan FIN to terminate option code selection Want to select another programming family Exit programming mode Scan One of Family Codes 1st Sc...

Page 23: ... without external keyboard APPLE ADB keyboard wedge interface Standard TTL RS 232 serial wedge interface Wand emulation interface USB keyboard interface for Microsoft Windows 98 2000 and Apple iMac 00 01 02 03 10 03 14 49 50 61 C4 Host Interface Selection JAPANESE VERSION DOS V keyboard wedge interface DOS V keyboard wedge interface direct connect NEC PC 98xx keyboard wedge interface IBM ThinkPad ...

Page 24: ...an END The hex value can be determined by referring to the HEX ASCII Reference Table on page A 6 To specify a two character Code ID scan the 2 digit hex values for each of the desired characters Then scan END If you only want to assign a one character Code ID for UPC E or EAN 8 scan the two digit hex code for the desired character Then Scan FIN and END bar codes Note To transmit the Code ID you ha...

Page 25: ...ult R UK Plessey default S Telepen default T 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2 digits Scan hex value 2...

Page 26: ... 32 HIBC Code 2 of 5 Family IATA Code 93 Code 11 MSI Plessey UK Plessey Telepen 00 01 02 03 04 05 06 07 08 09 10 11 12 13 FACTORY DEFAULT If your application is reading known limited bar code symbologies you may increase the reading speed and decrease the reading error possibility by enabling those known symbologies only Furthermore to add the Symbology ID into the transmitted data is also helpful...

Page 27: ...isable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 8 9 A Code 39 Min Length Default 04 Minimum length Scan 2 digits from the option code chart in the Appendix 2 digits Code 39 Max Length Default 99 Maximum length Scan 2 digits from the option code chart in the Appendix 2 digits FACTORY DEFAU...

Page 28: ...nsmission Enable abcd abcd start stop symbol transmission Enable ABCD TN E start stop symbol transmission Enable abcd tn e start stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 8 9 A B C Codabar Min Length Default 04 Minimum length Scan 2 digits from the option code chart in t...

Page 29: ...C E check digit transmission Enable UPC E check digit transmission Disable UPC leading 1 portion Enable UPC leading 1 portion 0 1 2 3 4 5 6 7 8 9 A B C D E F UPC E EAN 8 Expansion Expand the 7 digit UPC E and 8 digit EAN to 12 digit UPC A and 13 digit EAN 13 UPC A E Standardization Expand the 7 digit UPC E and 12 digit UPC A to 8 digit UPC 8 to 13 digit EAN 13 with 1 zero insertion UPC Lead 1 Nume...

Page 30: ... EAN 8 check digit transmission Enable EAN 8 check digit transmission Disable ISBN ISSN Conversion reading check Enable ISBN ISSN Conversion reading check 0 1 2 3 4 5 6 7 8 9 A B IATA Settings Select 15 digit fixed length IATA checking Select variable length IATA Disable check digit verification Enable check digit automatic verification Enable S N checking digit verification only Enable CPN checki...

Page 31: ...ation Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 8 9 A Code 2 of 5 Min Length Default 06 Minimum length Scan 2 digits from the option code chart in the Appendix 2 digits Code 2 of 5 Max Length Default 99 Maximum length Scan 2 digits from the option code chart in the Appendix 2 digits German Postal Setting Disable Enable 0 1 FACTORY DEFAULT The scanner can deco...

Page 32: ...ode 11 Min Length Default 04 Minimum length Scan 2 digits from the option code chart in the Appendix 2 digits Code 11 Max Length Default 99 Maximum length Scan 2 digits from the option code chart in the Appendix 2 digits Code 93 Settings Disable check digit transmission Enable check digit transmission 0 1 Code 93 Min Length Default 03 Minimum length Scan 2 digits from the option code chart in the ...

Page 33: ... MSI Plessey Min Length Default 04 Minimum length Scan 2 digits from the option code chart in the Appendix 2 digits MSI Plessey Max Length Default 99 Maximum length Scan 2 digits from the option code chart in the Appendix 2 digits Code 128 EAN 128 Settings Disable function code conversion Enable function code conversion 0 1 Code 128 EAN 128 Min Length Default 04 Minimum length Scan 2 digits from t...

Page 34: ...lt 04 Minimum length Scan 2 digits from the option code chart in the Appendix 2 digits UK Plessey Max Length Default 99 Maximum length Scan 2 digits from the option code chart in the Appendix 2 digits Telepen Settings Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission 0 1 2 3 Telepen Min Length Default 04 Minimum length Scan ...

Page 35: ...ugal QWERTY Norway QWERTY Latin America QWERTY Italy QWERTY Netherlands QWERTY Denmark QWERTY Belgium AZERTY Switzerland Germany QWERTY Iceland QWERTY Universal only available for IBM PC AT PS VP in MS DOS and Windows Mode 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 99 FACTORY DEFAULT Please refer to the HEX ASCII Table listed in Appendix A to determine HEX codes for characters symbols and fun...

Page 36: ... Maximum 15 character input scan FIN to terminate this selection FIN 00 7F FIN Postamble None 1 15 characters Maximum 15 character input scan FIN to terminate this selection FIN 00 7F FIN Character Frame Control None 00 99 msec Scan 2 digits from the option code chart in the Appendix 2 digits Intermessage Delay None 00 99 x5 msec Scan 2 digits from the option code chart in the Appendix 2 digits In...

Page 37: ...er These two parameters are used to synchronize data communication when 1 the data transmission speed is too fast characters may be skipped 2 multitasking operation system or host computers in a network may slow down the keyboard handling 3 various notebook or desktop PC systems require different timing parameter settings Please always add one extra unit as a safety margin when adjusting these two...

Page 38: ...fined character 1 character 0 1 2 3 4 5 6 7 00 7F Preamble None 1 15 characters Maximum 15 character input scan FIN to terminate this selection FIN 00 7F FIN Postamble None 1 15 characters Maximum 15 character input scan FIN to terminate this selection FIN 00 7F FIN FACTORY DEFAULT The record suffix and postamble differ in that the record suffix is always last and follows a postamble Serial Interf...

Page 39: ...ime Out Control None 200 mseconds 500 mseconds 1 second 2 seconds 5 seconds User defined value seconds 0 1 2 3 4 5 6 2 digits FACTORY DEFAULT When the RTS CTS Hardware Handshaking option is selected the RTS request to send and CTS clear to send signals will be issued before normal data communication This option is very helpful to ensure the reliability of data communication When the ACK NAK Softwa...

Page 40: ...onds 100 mseconds Delay time before data transmission 0 1 2 3 4 5 6 Module Time Extremely short Short Medium Long Time base of minimum narrow bar 0 1 2 3 Narrow Wide Ratio 1 2 1 2 5 1 3 0 1 2 Code 39 Emulation Disable standard Code 39 emulation Enable standard Code 39 skip emulation Enable standard Code 39 replace emulation 0 1 2 FACTORY DEFAULT Code 39 Skip When this option is selected all scanne...

Page 41: ...ime the scanner enters the idle state after the pre defined auto power off duration Alternative Mode When this operation mode is selected the scanner keeps the light source of the scanner turned on and disables the infrared sensor before the pre defined auto power off duration Because you do not have to press the trigger frequently it is very convenient for multiple scanning After each good read t...

Page 42: ...es the user with a helpful tool to use when the printing quality of the bar code is poor This is a programmable feature in IT3220 units with software revision AXX and 3060 80B with software revision CXX Units using later software revisions IT3220 revision BXX and VT3060 80B DXX scanners perform this feature automatically without any extra programming To reduce the error reading rate further we als...

Page 43: ...e Continued power on Toggle mode Repeat reading Diagnostic mode Test reading 0 1 2 3 4 5 6 7 Buzzer Tone Adjust Buzzer tone mute Buzzer tone low Buzzer tone medium Buzzer tone high Buzzer tone extremely high Good read beep before data transmission Good read beep after data transmission Power on beep No power on beep 0 1 2 3 4 5 6 7 8 Scanning Tolerance Printing Quality Control Regular standard pri...

Page 44: ...vel Mode or Diagnostic Mode Scan Voting Scan Voting is the number of times the same bar code is decoded before it is transmitted This feature is useful when the bar codes being read are of poor quality It should also be noted that this feature is not available if you have selected Low Power Mode Manual Trigger Mode Level Mode or Diagnostic Mode Auto Power Off Duration The Auto Power Off Duration i...

Page 45: ...s 0 1 2 3 4 5 Auto Power Off Duration Short around 2 seconds Medium around 3 4 seconds Long around 5 6 seconds Extremely long around 7 8 seconds 0 1 2 3 Pulse Driven Duty 1 2 duty cycle 2 3 duty cycle 3 4 duty cycle 4 5 duty cycle 0 1 2 3 Dollar Sign Control Dollar sign output as Dollar sign output as Japanese Yen 0 1 FACTORY DEFAULT The Debounce Time Control feature is available in the IT3220 pri...

Page 46: ...match required Enable format match not required If data verifier is false the original scanned bar code data will be transmitted 0 1 The Data Editor is a very powerful Artificial Intelligence based data editing expert system provided specifically for the 3060B 3080B 3220 bar code scanners Through the Data Editor you can process the scanned data prior to transmitting in many ways such as Insert Del...

Page 47: ...ertion Disable Enable 2 digits identified position max 3 insertion characters FIN 2 digits position Hex value for each character FIN 1 3 characters to insert FACTORY DEFAULT The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computer or terminal It allows you to select desired bar code symbologies for formatter control and provides Multiple Position ...

Page 48: ...able 2 digits checking position 1 identified character FIN 2 digit HEX value position 00 7F The Data Verifier is used to provide advanced verification for error free scanning and to work as an Embedded Data Transmitting Filter All data must conform to the Identified Bar Code Symbologies Identified Data Length and one to three Identified Characters in the checking position Otherwise the scanner wil...

Page 49: ...t decimal value position 00 7F FACTORY DEFAULT The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to select desired bar code symbologies for replacer control and provides Multiple Position Replacement in the identified position All data must conform to the Identified Bar Code Symbologies and one to three Identified...

Page 50: ...ata including the data of identified position 0 1 FACTORY DEFAULT The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to select desired bar code symbologies for organizer control and provides a maximum of two identified positions to send the data before or after It also allows you to control the transmitted data in...

Page 51: ...lowing to calculate the actual position for identification X X X X X X X X X X X 00 01 02 03 04 05 06 07 08 09 10 Application Example The bar code label is an all numeric 16 digit Interleaved 2 of 5 which includes the information of 6 digit date code 6 digit serial number and 4 digit unit price in that order The data code always starts with a 9 If a scanned bar code meets the above criteria the da...

Page 52: ...laced character to 41 Hex value for A At this point the data string is as follows A81025 TAB SN123456 TAB 9876 TAB We still need to delete the 98 from the string to get the desired output Data Organizer Scan Organizer Control and set bar code symbology to 08 Scan 1st Organization and set the identified position to 16 then set the data transmission to 0 before The character position which counts th...

Page 53: ...tain a Return Material Authorization number RMA before returning the product Main Office HHP Service Department 7510 East Independence Boulevard Charlotte NC 28227 Product Service Department Telephone 800 782 4263 Fax 704 566 9904 For service in Europe please contact your HHP representative or your local distributor European Office Hand Held Products Inc Nijverheidsweg 9 5627 BT Eindhoven The Neth...

Page 54: ...eld Products Inc Bon Marusan 8F 3 5 1 Kanda Jinbocho Chiyoda ku Toyko 101 Japan Telephone Int 81 3 5212 7392 Fax Int 81 3 3261 7372 For service in Latin America please contact your HHP representative or your local distributor Latin America Office Hand Held Products Inc 5117 Castello Drive Suite 1 Naples FL 34103 Telephone 239 263 7600 Fax 239 263 9689 Application Support If you need assistance ins...

Page 55: ...x number 315 685 4960 E mail tech_support hhp com Europe Telephone European Ofc Int 31 40 242 4486 U K Ofc Int 44 1925 240055 E mail euro_support hhp com Asia Telephone Int 852 2511 3050 or 2511 3132 E mail asia_support hhp com Latin America Telephone Int 56 2942 2495 or 2942 8371 E mail la_support hhp com ...

Page 56: ...er s expense during the Warranty Period to HHP s factory or authorized service center for inspection No product will be accepted by HHP without a Return Materials Authorization which may be obtained by contacting HHP In the event that the product is returned to HHP or its authorized service center within the Warranty Period and HHP determines to its satisfaction that the product is defective due t...

Page 57: ...LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU All provisions of this Limited Warranty are separate and severable which means that if any provision is held invalid and unenforceable such determination shall not affect the validity of enforceability of the other provisions hereof Limited Warranty Duration The Limited Warranty duration fo...

Page 58: ...The following provides information about the most popular cable adapters including PC AT Keyboard Wedge Cable Converter PS 2 Keyboard Wedge Cable Converter General Notebook PC PS 2 Direct Link Cable Converter USB Type A Direct Link Cable Converter APPLE ADB Keyboard Wedge Cable Converter IBM ThinkPad Keyboard Wedge Cable Converter IBM ThinkPad Direct Link Cable Converter NEC 98xx Keyboard Wedge Ca...

Page 59: ... M F Connectors Apple PowerMac ADB Keyboard Wedge Cable Converter 4P Mini DIN M F Connectors Illustration Description NEC 98xx Keyboard Wedge Cable Converter 8P Mini DIN M F Connectors IBM ThinkPad Direct Link Cable Converter 6P Mini DIN Male Connector IBM ThinkPad Keyboard Wedge Cable Converter 6P Mini DIN M F Connectors RS 232 Serial Cable Converter RS 232 Peer to Peer Interface 25P D Sub Female...

Page 60: ...ription RS 232 Serial Wedge Cable Converter 25P D Sub M F Connectors Embedded Power Jack Notebook PS 2 Keyboard Direct Link Cable Converter 6P Mini DIN Male Connector Wand Emulation Interface Cable Converter 9P D Sub Female Connector ...

Page 61: ... high medium 08 Completing the master default and group default 3 short beeps low high low 09 Completing the system information listing 3 short beeps medium high medium 10 Good reading 1 short beep adjustable tone 11 Programming error Invalid programming scan 1 long beep medium 12 Scanning FIN to finish programming selection 2 short beeps medium medium 13 Finishing the programming selection automa...

Page 62: ...meric Pad 24 CAN 18H HOME 09 HT 09H TAB 25 EM 19H END 10 LF 0AH F2 26 SUB 1AH PAGE UP 11 VT 0BH F3 27 ESC 1BH PAGE DOWN 12 FF 0CH F4 28 FS 1CH UP 13 CR 0DH ENTER Carriage Return 29 GS 1DH DOWN 14 SO 0EH F5 30 RS 1EH LEFT 15 SI 0FH F6 31 US 1FH RIGHT To emulate the key functions above program the scanner by using the corresponding ASCII hex value For example if you want to program in a suffix of a ...

Page 63: ...mily In the Hex ASCII Table you will find the HEX value of is 24 Scan the option code 2 listed on the foldout back cover Scan the option code 4 listed on the foldout back cover Scan the system command FIN Finish to terminate Preamble setting Scan the system command End to exit the programming mode for normal operation HEX ASCII Reference Table 0 1 2 3 4 5 6 7 0 NUL DLE SPACE 0 P p 1 SOH DC1 1 A Q ...

Page 64: ...Appendix A A 7 Bar Code Command Menu Option Code 0 9 A F System Command 0 8 4 C 1 9 5 D 2 A 6 E 3 B 7 F FIN Finish END Exit System List SYSLIST Master Default M_DEFAULT ...

Page 65: ...dix A A 8 Sample Bar Codes Codabar A13579B Code 39 BC321 Interleaved 2 of 5 1234567890 Code 128 Code 128 Code 93 123456 9 Matrix 2 of 5 6543210 Code 2 of 5 123456 EAN 13 9 780330 290951 UPC A 0 123456 7890 5 ...

Page 66: ...de System Command Bar Code System Command Set PC AT PS 2 Keyboard Wedge System Information List SYSLIST Keyboard Replacement Factory Default Setting M_DEFAULT RS 232 Serial Interface USB Keyboard Interface HHP SET Host Link ...

Page 67: ......

Reviews: