background image

 

 

 

Figure 6: AP321 and AP321e Back View

 

 

 

AP321 and AP321e Connections

 

Table 1

 

External Interfaces 

Item Name

 

Specifications

 

DC Power 
Socket

 

The AP has a single 48V DC power jack socket to support 
powering through an AC

-

to

-

DC power adapter, If PoE is 

not available, an optional AC

-

DC adapter kit (sold 

separately) can be used to power the

 

AP.

 

2.5 Gigabit 
Eth0

 

1x 100/1000/2.5GBASE

-

T autosensing (RJ

-

45) port, Power 

over Eth0 (PoE)

 

1 Gigabit 
Eth1

 

1x 10/100/1000BASE

-

T autosensing (RJ

-

45) port, Power 

over Eth1 (PoE)

 

Console

 

The console port is an RJ

-

45 female connector and can be 

used to connect to a terminal for direct local 
management.

 

Note

: Currently for use by Service & Support only.

 

USB

 

USB 2.0 host interface (Type A, output current 0.5A )

 

Reset

 

Factory reset. Press reset button for 5s, AP LEDs will 
quickly flashing for 3s, then AP will restart and restore 
factory configurations.

 

Security 
Lock Slot

 

The AP is equipped with a security lock slot for additional 
security.

 

Table 2

 

Ethernet Port Pinout 

 

Connector

 

Pin

 

Signal Name

 

PoE

 

 

 






 
 
 
 
 
 

 

1

 

 

PoE

2

 

RJ45_DA–

 

PoE

3

 

 

PoE+

 

4

 

 

PoE+

 

5

 

RJ45_DC–

 

PoE+

 

6

 

RJ45_DB–

 

PoE+

 

7

 

 

PoE

8

 

RJ45_DD–

 

PoE

Table 3

 

Console

 Port Pinout 

Connector

 

Pin

 

Signal Name

 

Function

 

 






 
 
 
 
 
 

 

3

 

TXD

 

Transmit

 

4

 

GND

 

Ground

 

5

 

GND

 

Ground

 

6

 

RXD

 

Receive

 

Pins not listed are not connected.

 

 

Note:  The  serial  console  port  allows  you  to  connect  the  AP  to  a 

serial terminal or a laptop for direct local management. This port is 

an RJ

-

45 female connector with the pinouts described in Table 3.

 

Currently for use by Service & Support only.

 

 

Power

 

The OAW

-

AP1320 series access point supports direct DC power adapter 

(48V DC nominal, sold separately) and Power over Ethernet (PoE).

 

The DC power connector port is located on the back of the device, as 
shown in Figure 6.

 

The PoE allows the Ethernet port to draw power from an IEEE 802.3at 
compliant source.

 

 

OmniAccess  Stella  AP  supports  the  power  adapter  provided  by 
ALE ONLY.

 

 

Before You Begin 

Refer to the sections below before beginning the installation process.

 

Pre

-

installation Checklist

 

Before installing your 

OAW-AP1320 Stellar access

 point, be sure that 

you have the following items:

 

 

8

-

conductor, CAT5 or better UTP cable of required length.

 

 

One of the following power sources:

 

 

IEEE 802.3at compliant Power over Ethernet (PoE) source 
(PoE switch or PoE injector), best with 2.5GbE PoE port.

 

 

AC

-

DC adapter (sold separately)

output voltage DC 48V, 

output current 

0.5A

 

 

A terminal or a notebook

 

 

Identifying Specific Installation Locations

 

You can mount the 

OmniAccess Stellar

 AP on a ceiling rail

 or on a wall

You should first determine the location of the installation. The 
installation position is located at the center of the required coverage 
area and should be free from obstructions or obvious sources of 
interference.

 

 

Minimize the number of  obstructions (such as walls) between the 
AP and user terminals.

 

 

Electronic equipment or devices (such as microwave ovens) which 
may  produce  radio  frequency  noise  should  be  away  from  the 
installation position of the AP.

 

 

It is strictly prohibited to install around stagnant water, water seepage, 
leakage  or  condensation.  Avoid  cable  condensation  or  water  seepage 
along the cables connecting to the AP.

 

 

AP Installation

 

Refer to mounting kits installation Guide.

 

 

Verifying Post

-

Installation Connectivity

 

The LED on the AP can be used at this point to verify that the AP is 
receiving power and initializing successfully.

 

 

 

 

 

 

Reviews: