9.
Attaching the Light Kit
and Glass Bowl
CAUTION - To reduce the risk of electrical
shock, disconnect the electrical supply circuit
to the fan before installing light kit.
1. Remove one of four mounting screws and
lockwashers on the switch cup below the
fan motor assembly. Loosen, but do not re-
move the other three mounting screws and
lockwashers (Figure 15).
2. Connect the blue and white wires exit-
ing the switch cup below the fan motor
assembly with the black and white wires
from the light kit assembly by connecting
the polarized plugs (blue to black; white to
white). Carefully push all wires back into
the switch cup.
3. Align the three key slots in the light kit as-
sembly with the three mounting screws and
lockwashers on the switch cup the were
loosened in step 1, place the light kit assem-
bly over the three screws, turn the light kit
assembly clockwise until it locks, tighten
the three screws.
4. Re-install the one mounting screw and
lockwasher that were removed in step 1 and
tighten firmly.
5. Remove the finial and the nut from the
threaded pipe of the light kit assembly.
Figure 15
Figure 16
6. With the power off, carefully position the
circline lamp (Max. 22 watt, provided) un-
der the lamp retainer, make sure the 4 pins
on the circline lamp are located at the bot-
tom near the connector from the ballast.
Snap both sides of the lamp retainer over
the circline lamp, carefully engage the con-
nector from the ballast with the 4 pins on the
circline lamp (Figure 16).
7. Position the glass bowl over the threaded
pipe and then secure by installing the nut
and finial finger tight (Figure 16).
DO NOT OVERTIGHTEN THE NUT. OVERTIGHT-
ENING THE NUT MAY CAUSE THE GLASS BOWL
TO BREAK.
Summary of Contents for Renwick