SPECIFICATIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

SELECTING A LOCATION 

 

The motion sensor’s maximum range is 90° detection width angle (Fig. 2). Mounting the fixture too high or in front of a sloped surface, such as 

an uphill walkway or driveway, may affect the motion sensor’s effectiveness. 

 

The motion sensor is less sensitive to movement toward or away from the motion sensor (Fig 1) and more sensitive to movement across its 

coverage area (Fig 2). 

 
rug 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

Select locations away from nighttime light sources, such as street lamps or other light fixtures. They may shine light onto the fixture’s photocell 

sensor (located in the motion sensor head). This light might trick the circuit to think it is daytime and not allow the fixture’s functions to operate. 

 

Select locations away from heat sources, such as heating vents, air conditioners, and heated swimming pools. 

 

Shade from a deep porch or an eave may not allow enough daylight to shine onto the photocell sensor and may trick the circuit to think it is 

nighttime, and subsequently cause the light to illuminate during the day. 

 

Motorized equipment, such as power tools, on the same electrical circuit may cause oscillations on the electrical line which might cause the 

fixture to malfunction 

 

 
 

 
 
 
 
 
 
 

 

NOTE

:

 

 

In order to preserve battery life, the minimum working temperature of the deck light  should not be 

lower than -10°Celsius. Temperature below -10°Celsius will harm the battery life. 

 

Do not storage exceed half year. Must charge at least once when storage half year, and must 
charge the battery (with protect circuit) when storage for three months.

 

 
 
 
 

 

CAUTION

:

 

 

Do not take out battery from fixture body. 

 

It is recommended to discharge the cell to the end, handing in the abandoned cell to related 
department unified, dispose of the cell in accordance with approved local, state, and federal 

requirements. Consult state environmental protection agency and/or federal EPA 

 
 
 
 
 

Technical Specifications

 

Up t      

 

 

 

 

Motion Sensor Range 

Up to 16.5 ft. (varies with surrounding temperature) 

Sensor Detection Angle 

90° 

Power supply 

AC 12V  

Installation Height 

Ideally, 1.31 ft. –0.65 ft. (0.4 – 0.2 m.) above the ground. 

Non-replaceable battery 

Rechargeable Li-ion Battery  3.7V, 800mA , 2.96 Wh 

Charging time 

4 hours at charging current 300mA 

Care and Cleaning 

□ 

Clean the fixture with a soft dry cloth. 

□ 

Do not use any cleaners with chemicals, solvents or harsh abrasives. 

 

 

Summary of Contents for KXX1501LX-01

Page 1: ...re connectors Stir 4 buttons up to ON Mode 1111 to make deck light on test mode Cover the PIR sensor with light blocking object to do preliminary function test Remove the light blocking object this pa...

Page 2: ...not touch the metal contacts CAUTION The wire from low voltage power unit should be 12 16 AWG type underground low Energy Circuit Cable IMPORTANT Protect the wiring by routing it in close proximity to...

Page 3: ...power tools on the same electrical circuit may cause oscillations on the electrical line which might cause the fixture to malfunction NOTE In order to preserve battery life the minimum working temper...

Page 4: ...4 AWG 12 AWG 121 180 Watts 14 AWG 12 AWG Not Recommended 181 240 Watts 14 AWG 12 AWG Not Recommended 241 300 Watts 12 AWG Not Recommended Not Recommended 600W Transformer 2x300 Watts 12 AWG Not Recomm...

Page 5: ...a luz de cubierta se encienda en el modo de prueba Cubra el sensor PIR con un objeto sombreado y realice una prueba funcional preliminar Al eliminar el objeto sombreado la luz de la trayectoria se ene...

Page 6: ...cipal de bajo voltaje No toque los contactos de metal para evitar lesiones PRECAUCI N El cable de la unidad de bajo voltaje debe ser un cable subterr neo de circuito de baja corriente tipo 12 16 AWG I...

Page 7: ...as herramientas el ctricas en el mismo circuito el ctrico pueden causar oscilaciones en la l nea el ctrica que pueden causar un mal funcionamiento del dispositivo Limpia la l mpara con un pa o suave y...

Page 8: ...AWG 12 AWG No Recomendado 181 240 Watts 14 AWG 12 AWG No Recomendado 241 300 Watts 12 AWG No Recomendado No Recomendado 600W transformador 2x300 Watts 12 AWG No Recomendado No Recomendado 900W transfo...

Page 9: ...dealer or an experienced radio TV technician for help Advertencia de la FCC Advertencia los cambios o modificaciones de esta unidad que no est n expresamente aprobados por la parte responsable del cu...

Reviews: