HAMPTON BAY KXX1501LX-01 Use And Care Manual Download Page 2

                         2 

 

Assembly and Installation 

 

 

Attaching and installing the light 

Connecting the wires 

 

Insert the fixture wire on the wire connector (B) into the groove located 

on the top of the ground stake (C). 

 

Ensure the fixture wire on the wire connector (B) stays in the center of 
the groove to avoid damage to the fixture wire. Screw the ground stake 
(C) into the lamp body (A). 

 

Prepare a hole in the installation location. Use a tool such as a 
screwdriver (not included) to prepare the installation hole to ensure the 

hole is not larger than the ground stake (C). 

 

Install the ground stake (C) in the ground by pushing on the lamp body 

(A). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

If  you need the path light to stay on 

 

Slided the swith (2) to the ON, then the path light will stay on. 

 

If you need to turn off the path light, you can slided the swith (2) to the 
OFF. 

 

 

WARNING

Never push the fixture into the ground by the lamp body (A) 

or use a hammer to insert the ground stake (C) into the ground

.

 

 

 

WARNING: 

The wire connector (B) contacts have sharp edges for 

piercing the main low voltage cable. To avoid injury, do not touch 
the metal contacts. 

 

 

CAUTION:

 The wire from low voltage power unit should be 12-16 

AWG type underground low Energy Circuit Cable. 

 

 

IMPORTANT:

  

 

Protect the wiring by routing it in close proximity to the light 
fitting, or next to a building structure such as a house or a 

deck.

 

 

The landscape wire and connector can also be hidden under 

stone or buried under grass at a maximum depth of 6 in. 

 

(15.24 cm).

 

 

Do not install the fixture within 10 ft. of a pool, spa, or fountain.

 

 

Do not submerge the fixture in water.

 

 

For the emergency use, when disconnected from the 

transformer (disconnect the power supply), it can still be used 
for 24 times induction.

 

 

Place the wire connector (B) on opposite sides of the low 
voltage cable (not included) from the transformer (not 
included) where the fixture will be located. 

 

Align and fit the main low voltage cable vertically to the slot of 

the wire connector (B). 

 

Press the wire connector (B) together until it is locked around 
the main low voltage cable. The pre-set prongs will pierce the 
cable insulation and establish contact with the electrical wire 
inside. 

 

Once the wire connector (B) is in place, it is recommended to 
wrap it with electrical tape (not included). 

 

After all fixtures are installed, turn on the transformer. 

 

Summary of Contents for KXX1501LX-01

Page 1: ...re connectors Stir 4 buttons up to ON Mode 1111 to make deck light on test mode Cover the PIR sensor with light blocking object to do preliminary function test Remove the light blocking object this pa...

Page 2: ...not touch the metal contacts CAUTION The wire from low voltage power unit should be 12 16 AWG type underground low Energy Circuit Cable IMPORTANT Protect the wiring by routing it in close proximity to...

Page 3: ...power tools on the same electrical circuit may cause oscillations on the electrical line which might cause the fixture to malfunction NOTE In order to preserve battery life the minimum working temper...

Page 4: ...4 AWG 12 AWG 121 180 Watts 14 AWG 12 AWG Not Recommended 181 240 Watts 14 AWG 12 AWG Not Recommended 241 300 Watts 12 AWG Not Recommended Not Recommended 600W Transformer 2x300 Watts 12 AWG Not Recomm...

Page 5: ...a luz de cubierta se encienda en el modo de prueba Cubra el sensor PIR con un objeto sombreado y realice una prueba funcional preliminar Al eliminar el objeto sombreado la luz de la trayectoria se ene...

Page 6: ...cipal de bajo voltaje No toque los contactos de metal para evitar lesiones PRECAUCI N El cable de la unidad de bajo voltaje debe ser un cable subterr neo de circuito de baja corriente tipo 12 16 AWG I...

Page 7: ...as herramientas el ctricas en el mismo circuito el ctrico pueden causar oscilaciones en la l nea el ctrica que pueden causar un mal funcionamiento del dispositivo Limpia la l mpara con un pa o suave y...

Page 8: ...AWG 12 AWG No Recomendado 181 240 Watts 14 AWG 12 AWG No Recomendado 241 300 Watts 12 AWG No Recomendado No Recomendado 600W transformador 2x300 Watts 12 AWG No Recomendado No Recomendado 900W transfo...

Page 9: ...dealer or an experienced radio TV technician for help Advertencia de la FCC Advertencia los cambios o modificaciones de esta unidad que no est n expresamente aprobados por la parte responsable del cu...

Reviews: