32
|
Hampton
®
H27E-11DirectVentFreestandingGasStove
installation
Diagram 7
Vertical
Terminations
1) Maintainthe1-1/2"clearances,exceptwhen
passing through a wall, ceiling, or at the
terminationwheretheuseofafirestopor
wallthimblereducestherequiredclearance
to1".Donotpackairspaceswithinsulation.
Checkthe"VentingArrangement"section
forthemaximumverticalriseoftheventing
systemandthemaximumhorizontaloffset
limitations.
2) Setthegasapplianceinitsdesiredlocation.
Drop a plumb bob down from the ceiling
to the position of the appliance flue exit,
andmarkthelocationwheretheventwill
penetratetheceiling.Drillasmallholeat
thispoint.Next,dropaplumbbobfromthe
rooftotheholepreviouslydrilledintheceil-
ing,andmarkthespotwheretheventwill
penetratetheroof.Determineifceilingjoists,
roofraftersorotherframingwillobstructthe
ventingsystem.Youmaywishtorelocatethe
applianceortooffset,asshownindiagram
8toavoidcuttingloadbearingmembers.
Diagram 4
7) InstalltheBackingPlateintothewallpenetra-
tionheatshieldandattachusing4screws.
Dia.4.
8) Connectallpipesectionstounitandinstall
intowall:
a) Measure pipe length required and cut to
length.Hint:usethecutendofthe6-5/8"
dia.outerpipeattheventterminalend.
b) Pushthepipesectionscompletelytogether,
theminimumpipeoverlapis1-1/4".Secure
all outer pipe joints by using at least two
screws.Locatethescrewsatthebottomof
thepipesothatthescrewheadsarehidden
onthefinalinstallation.
NOTE: For best results and optimum
performance with each approved vent-
ing system, it is highly recommended
to apply “Mill-Pac” sealant (supplied) to
every inner pipe connection. Failure to do
so may result in drafting or performance
issues not covered under warranty.
Diagram 5
c) Beforeconnectingtheventpipetothevent
termination,slidetheblackdecorativewall
thimblecoverovertheventpipe,thenslide
theWallPenetrationHeatShieldoverthe
ventpipe.Dia.3.
d) Slide the appliance and vent assembly
towardsthewallcarefullyinsertingthevent
pipeintotheriserventterminalassembly.It
isimportantthattheventpipeextendsinto
the RiserVent Backing Plate a sufficient
distancesoastoresultinaminimumpipe
overlap of 1-1/4 inches. Secure the con-
nectionbetweentheventpipeandthevent
capbyattachingthetwosheetmetalstrips
extendingfromtheRiserVentBackingPlate
intotheouterwalloftheventpipe.Usetwo
aluminumscrewsprovidedtoconnectthe
stripstothepipesection.Bendanyremain-
ing portion of the sheet metal strip back
towardstheventcapandcutoffanyexcess,
itwillbeconcealedbythedecorativewall
thimblecover.Seediagram5.
9) Slidethedecorativewallthimbleuptothe
wallsurfacebeingcarefulnottoscratchthe
paint.Seediagram5.
10)Backoutside:Applysealanttothe4"inner
flueandslidetheRiserVentFrontintothe
BackingPlateandfastenwith8screws.
IMPORTANT:
When connecting the pipe to the Riser
Vent, apply Mill-Pac to the inner pipe on
the Riser Vent Terminal, around the bead.
Ensure that the vent pipe is pushed past
the bead for a secure fit.
11)Seal around the outer edge of the Riser
VentBackingPlate.
Summary of Contents for H27
Page 51: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 51 notes...