Hampton

®

 H27-10 Direct Vent Freestanding Gas Stove

  |     

29

29

installation

Termination

Cap

Top Adaptor

Existing

Metal

Chimney

System

Aluminum

Flex Pipe

Retro

Connector

Any Simpson

Dura-Vent

black direct vent

pipe plus an

adjustable length

to make a

proper connection.

CONVERTING CLASS-A  

METAL CHIMNEY OR 

MASONRY  CHIMNEY TO  

DIRECT VENT SYSTEM

There are two different types of direct vent conver-

sion systems listed below. Follow the appropriate 

directions for your installation.

A)  Through an existing factory built metal chimney 

going through the ceiling: A typical conversion 

of this type is shown in diagram 1. The concept 

of direct vent conversion is to connect an adap-

tor to an Underwriters Laboratories (UL) listed 

4 inch diameter aluminum flex pipe which is 

then passed down through the center of the 

existing metal chimney system. Three sizes 

of Top Adaptors are available from Simpson 

Dura-Vent. The Retro Connector is attached 

to the bottom of the flex pipe. The Top Adaptor 

and the Retro Connector are attached to the 

existing chimney with sheet metal screws. The 

appliance is then connected to the chimney 

with appropriate black direct vent pipe and an 

adjustable length  section.

B) Through the wall of an existing masonry 

chimney: A typical conversion of an existing 

masonry chimney is shown in Diagram 6. A 

Top Adaptor and Flashing are used at the 

top of the masonry chimney. The 4 inch alu-

minum liner is connected to the adaptor and 

is passed down the chimney and out through 

the  masonry wall and attached to the Retro 

Connector. The Retro Connector is attached 

to the masonry wall and then connected to the 

direct vent pipe leading to the appliance.

Prior to installation and connection of the vent 

system to a factory-built or masonry chimney, 

the chimney must be inspected and thoroughly 

cleaned by a qualified service person, such as 

a certified chimney sweep or home inspection 

service.

 

The direct vent system must not be connected 

to a damaged factory-built or masonry chimney.

For factory built, zero clearance, and masonry 

chimneys cleanout doors and caps or plugs 

for cleanout tee fittings and ash dumps shall 

be secured in place and sealed before install-

ing a Direct Vent system within the chimney.

If the appliance shuts off during operation, 

contact a qualified service person to determine 

if a negative pressure and/or leaky chimney 

condition exists. Do not operate the appliance 

until the problem is corrected.

Approved for US Installations Only

The  use  of  an  existing  chimney  as  an  air 

intake is not covered under the ANSI Z21.88-

2014, CSA 2.33-2014 test methods and the 

resulting ITS/WHI product certification. The 

code  Authority  Having  Jurisdiction  must 

be consulted prior to proceeding with this 

installation method.

Converting a Factory Built Metal 

Chimney

1)  Remove the existing chimney cap.

2)  Measure the distance from the top end of the 

chimney to the bottom of the ceiling support 

box, add 3" (76mm) to this measurement, 

and cut a section of the 4" flex pipe to that 

length (the flex should already be extended 

to its nominal length).

4)  Pass the flex pipe down through the center 

of  the  chimney  system,  and  center  the 

adaptor on the top of the chimney pipe. 

Drill four 1/8" diameter holes through the 

adaptor and into the chimney top. Insure 

that   you are in fact, drilling into the metal 

on  the chimney. Twist-lock the Termination 

Cap onto the Adaptor. (Diagram 3 and 4).

Diagram 1

Diagram 2

Diagram 3

5)  Pull the flex pipe down through the ceiling 

support box, until it protrudes approximately 

3" (76mm). Connect the flex pipe to the Retro 

Connector by slipping it into the 

 

4-3/4" diameter sleeve on the top side of 

the Connector. Use 3 sheet metal screws 

to assemble these two parts.

6)  Push the flex pipe back up into the ceiling 

support box, center the Retro Connector, and 

attach it to the support box, or decorative 

sleeve  for  double  wall  solid  packed  pipe, 

with the sheet metal screws (supplied).  

The holes in the Retro Connector are pre-

punched. Diagram 5.

Diagram 4

Diagram 5

3)  Connect the end of the flex pipe section to 

the underside of the Top Adaptor using 3 

sheet metal screws. Diagram 2.

7)  The connection between the appliance and 

the Retro Connector may be completed with 

sections of black direct vent pipe, together 

with an adjustable length.

Summary of Contents for H27-LP10

Page 1: ...mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your bu...

Page 2: ...has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model H27 10 has been approved by Warnock Hersey Intertek for both safety and efficiency...

Page 3: ...System 21 DV Stove Horizontal Vent Kit 22 Residential And Manufactured Homes Mobile Homes 24 Minimum Horizontal Termination Installations 24 Dura Vent Termination Kit 25 Horizontal Terminations 26 Ve...

Page 4: ...ight Side Wall Vertical Pipe See Manual for details Model Modele H27 NG10 Model Modele H27 LP10 Part 919 485a Colour Everything black on grey except for items indicated as being printed in red Size Pr...

Page 5: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Page 6: ...6 Hampton H27 10 Direct Vent Freestanding Gas Stove 6 dimensions UNIT DIMENSIONS WITH VERTICAL VENTING 17 13 16 452 mm...

Page 7: ...Hampton H27 10 Direct Vent Freestanding Gas Stove 7 7 installation UNIT DIMENSIONS WITH HORIZONTAL VENTING 452 mm...

Page 8: ...alfirst Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation Note Failure to follow the instructions could cause a malfunction of th...

Page 9: ...f the appliance be kept clean and free from excessive lint from carpeting 4 See general construction and assembly in structions The appliance and vent should be enclosedwheninstalledinorpassingthrough...

Page 10: ...wall if installing the blower option so the fan can be easily installed and or serviced LOCATING YOUR GAS STOVE When selecting a location for your stove ensure that the clearances listed above are met...

Page 11: ...n the back of the left side access panel 7 Loosen the 2 bolts on fan assembly and slide the fan into the slots provided on the unit 8 Once the fan assembly is fitted into the assigned slots tighten th...

Page 12: ...e steps OPTIONAL WALL THERMOSTAT INSTALLATION 1 Open the front panel and remove the cover plate by removing two screws 2 Disconnect one of the wires from the switch as shown in the picture below to co...

Page 13: ...logy Co Axial system The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room...

Page 14: ...of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air...

Page 15: ...Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvani...

Page 16: ...Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK Vertical Termination Kit Disc 4DT VKC 4DHTK 4...

Page 17: ...nt Direct Vent American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp and ICC Excel AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd D...

Page 18: ...m two 45o elbows If the vent is ENCLOSED in a chase min size 9 x 9 maintain a 1 1 4 clearance to combustibles May be installed in Manufactured Mobile Homes after first sale Horizontal Terminations for...

Page 19: ...of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total ve...

Page 20: ...feet total horizontal Please note min 1 foot between 90o elbows is re quired Vent restrictor position A fully open refer to the Vent Restrictor Position section Lengths do not include elbow indicated...

Page 21: ...to be attached to two 3 76mm co linear aluminium flex running the full length of the chimney See the Venting Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdi...

Page 22: ...th the starter collar and the 90o elbow Crimped section of rigid pipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including vent terminal 2 Assembleatrialf...

Page 23: ...and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia flex liner out fully and get a trial fit of the liner onto the 4...

Page 24: ...rements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Before cutting the vent hole through the wall ensure that...

Page 25: ...ical to horizontal type installations Warning Alwaysmaintainrequired clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Theminimumclearancereq...

Page 26: ...enetrated is constructed of non combustible material i e masonry block or concrete a 7 diameter hole is acceptable a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run towa...

Page 27: ...dden on the final installation NOTE For best results and optimum performancewitheachapprovedventing system it is highly recommended to ap ply Mill Pac sealant supplied toevery inner pipe connection Fa...

Page 28: ...lt in drafting or performance issues not covered under warranty 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round SupportBox Ins...

Page 29: ...y chimneys cleanout doors and caps or plugs for cleanout tee fittings and ash dumps shall be secured in place and sealed before install ing a Direct Vent system within the chimney If the appliance shu...

Page 30: ...Gas min 5 0 w c Propane min 12 0 w c Manifold Pressure Natural Gas 3 5 0 2 w c Propane 10 0 2 w c 8 Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails slide sto...

Page 31: ...the valve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pres sure...

Page 32: ...ll off the pilot cap to expose the pilot orifice 6 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1...

Page 33: ...and refer to the dia grams Ifthelogsarebrokendonotusetheunituntiltheyare replaced Broken logs can interfere with the pilot operation The gas log kit Part 350 930 contains the following a Rear Log b L...

Page 34: ...ftheburner in and around where the embers are placed Avoid stacking platinum embers 6 Place the center cross log D so it rests in the notch located on the top of the rear log position as shown below L...

Page 35: ...ck for proper draft CAUTION Anyalterationtotheproductthatcausessooting orcarboningthatresultsindamagetotheexterior faciaisnottheresponsibilityofthemanufacturer BACK UP BATTERY In the event of a power...

Page 36: ...ot surface and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be...

Page 37: ...Hampton H27 10 Direct Vent Freestanding Gas Stove 37 37 operating instructions WIRING DIAGRAM WITH THERMOSTAT Thermostat Optional Millivolt...

Page 38: ...ned Never operate the appliance with the glass removed 5 Verifythattheventingandcapareunobstructed 6 Verify log placement If the pilot cannot be seen when lighting the unit the logs have been incorrec...

Page 39: ...oard will go into lock out The system will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on the remote b After approximately 2 seconds turn on ON OFF s...

Page 40: ...nsult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risquede d clencher un incendie ou une explosion e...

Page 41: ...at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WARNING CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATUREAND...

Page 42: ...ocheckmechanicalsupportssuch as Wall Straps or plumbers tape for rigidity 5 Verify proper operation after servicing LOG REPLACEMENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and al...

Page 43: ...o stove 4 Disconnect gas line to stove 5 Disconnect 3 8 NPT pipe from 90o elbow on valve or flex connector 6 Disconnect 3 wires from spark igniter assembly 7 Lift off the Cast Top and remove the Cast...

Page 44: ...ctor 350 004 Baffle Plate for Firebox Part Description Part Description Part Description 350 022 Casting Mount Bracket Fan Air Divider 50 W260260 Top Relief Frame Gasket 51 942 117 Top Relief Frame 52...

Page 45: ...Halogen Light Socket Assembly 910 997 Halogen Light Bulb 120 Volt 20 Watt JCD Bi Pin Gy6 35 910 157 P Blower Motor Only with Squirrel Cage 911 093 10 foot Extension Cord 911 027 Battery Holder W 9V Sn...

Page 46: ...46 Hampton H27 10 Direct Vent Freestanding Gas Stove 46 notes...

Page 47: ...d if requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufactur...

Page 48: ...________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___...

Reviews: