background image

 

Assembly — Hanging the Fan

11

HAMPTONBAY.COM

Please contact 1-855-HD-HAMPTON for further assistance.

 

4

Attaching the fan to the 
electrical box

5b

5a

Hanging instructions for 
standard mounting

Hanging instructions for 
close-to-ceiling mounting

WARNING:

 

The tab in the ring must rest in the groove of

the hanger ball (E). Failure to properly seat the tab in the
groove could cause damage to the wiring.

WARNING:

 

The hook is only to hold the fan while attaching

wiring. Failure to hang as instructed may result in the tab
breaking causing the fan to fall. The hook must pass from the
inside to the outside of the canopy.

     Carefully lift the fan motor assembly (G) up to the 

mounting bracket (A) and seat the hanger ball (E) in 
the mounting bracket (A) socket. Make sure the tab 
on the mounting bracket (A) socket is properly seated 
in the groove in the hanger ball (E). This will help to 
balance the ceiling fan.

  

   Carefully lift the fan motor assembly (G) up to the 

mounting bracket (A) and hang the fan on the hook 
provided using one of the holes at the outer rim of the 
canopy (C).

 

E

G

A

A

C

G

     Pass the 120-volt supply wires through the center 

hole in the mounting bracket (A).

     Install the mounting bracket (A) to the outlet box (NN) 

with the screws and washers provided with your 
outlet box. When using “close-to-ceiling” mounting, it 
is important that the mounting bracket (A) be level. If 
necessary, use leveling washers (not included) 
between the mounting bracket (A) and the outlet box 
(NN). Note that the flat side of the mounting bracket 
(A) is toward the outlet box (NN).

     Securely tighten the two mounting screws.

WARNING:

 

To reduce the risk of fire, electric shock or 

other personal injury, mount the fan only to an outlet box or 
supporting system marked acceptable for fan support and 
use the mounting screws provided with the outlet box.

A

NN

C

Summary of Contents for GAZEBO YG188-BN

Page 1: ...NK YOU THANK YOU 1 855 HD HAMPTON HAMPTONBAY COM Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday call Hampton Bay Customer Service...

Page 2: ...ting Instructions Installation Assembly Standard Ceiling Mounting Close to Ceiling Mounting Hanging the Fan Attaching the Fan Blades Installing the Light Kit 2 3 4 4 4 4 5 6 7 8 9 9 10 11 14 15 Operat...

Page 3: ...capable of reliably supporting a minimum of 35 lbs 15 9 kg or less Use only UL listed outlet boxes marked FOR FAN SUPPORT 4 The fan must be mounted with a minimum of 7 ft 2 1m clearance from the trai...

Page 4: ...est useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the w...

Page 5: ...bled Blade attachment screw and rubber washer not to scale Blade arm screw and lock washer preassembled Clevis pin preassembled Cotter pin preassembled Collar setscrew preassembled Collar mounting scr...

Page 6: ...tity 1 5 5 1 1 Part Part A B C D E F Quantity Quantity 1 1 1 1 1 1 Description Description Mounting bracket preassembled Canopy ring preassembled Canopy Canopy bottom cover preassembled Hanger ball do...

Page 7: ...standard downrod installation the distance from the ceiling to the bottom of the fan blades will be approximately 12 in The close to ceiling installation reduces the distance from the ceiling to the...

Page 8: ...ree different ways to mount the outlet box NN not included NN NN OO NN NN A Installation MOUNTING OPTIONS MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount th...

Page 9: ...er ball lower the hanger ball and remove the pin Remove all three pieces from the downrod and assemble them onto the new longer downrod before proceeding to the downrod installation Route the wires ex...

Page 10: ...py ring B and canopy C over the collar at the top of the fan motor assembly G Align the mounting holes in the bottom of the canopy C with the holes in the top of the fan motor assem bly G Fasten using...

Page 11: ...erly seated in the groove in the hanger ball E This will help to balance the ceiling fan Carefully lift the fan motor assembly G up to the mounting bracket A and hang the fan on the hook provided usin...

Page 12: ...AA with electrical tape Make sure there are no loose strands or connections Connect the ground conductor of the 120V supply this may be a bare wire or a wire with green colored insulation to the green...

Page 13: ...ock washer BB are engaged and firmly tightened BB NN A BB E BB A BB B C B C Slide the canopy C up to the ceiling Make sure you have placed the wires safely into the outlet box NN Secure the canopy C t...

Page 14: ...between rotating fan blades H Attach the blades H to the blade arms I using the three blade attachment screws and rubber washers CC Start a screw and rubber washer CC into the blade arm I but do not...

Page 15: ...k Carefully push all wires back into the switch housing SS Install the light kit J onto the switch housing SS with the three light kit mounting screws II provided Be sure to tighten all screws SS J TT...

Page 16: ...ol weather depend on factors such as the room size ceiling height number of fans and so on To turn the light On or Off pull the chain that is attached to the switch housing SS KK 13 Installing the fan...

Page 17: ...blade rotation REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS The reverse switch is located on the surface of the switch housing This switch controls directions forward sw...

Page 18: ...the ceiling to the canopy It should not touch the ceiling Make sure your ceiling box is secure and rubber isolator pads are used between the mounting bracket and outlet box The fan will not start The...

Page 19: ...re nut Canopy mounting screws with lock washer preassembled Blade attachment screw and rubber washer Blade arm screw and lock washer preassembled Clevis pin preassembled Cotter pin preassembled Collar...

Page 20: ...N HAMPTONBAY COM Retain this manual for future use YG1880001 A Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday call Hampton Bay Cu...

Reviews: