B
F
A
7
5b
Anchor installation
6
7
BB
F
CC
Installation (continued)
Drill a 7/32 in. hole at each mark on the ceiling, and insert
the anchors (CC) into the mounting surface.
Insert the Phillips screws (BB) through the track section (F),
and tighten to the anchors (CC).
Attaching the mounting plate to the track
Connecting the canopy to the track
□
□
□
□
□
□
Tighten the track mounting screws (A) to secure the track
section (F) to the mounting plate (B).
Twist the twist-lock connector (C) into the track section (F).
Secure the canopy (D) to the mounting plate (B) by tightening
the previously removed canopy screws (E).
When the twist-lock connector (C) is twisted into position on
the track section (F), make sure the two copper tabs on the
side of the twist-lock connector (C) align with the two copper
strips inside the track section (F). This is necessary to
maintain polarity.
Installing the track head to the track
8
NOTE:
The ground side of the track head (G) connector is the side with two
metal tabs. The ground side of the track section (F) has an indented groove
on the face and two internal copper strips. The track head (G) can only be
assembled if the ground sides of the track head (G) connector and the track
section (F) are aligned.
□
□
□
Identify the ground side on the track head (G) connector and track
section (F).
Push the top portion of the track head (G) connector into the slot of the
track section (F).
Pull down the connector’s locking tab (H). Twist the ground side of the track
head (G) connector toward the ground side of the track section (F) until the
track head (G) connector snaps into place.
C
F
B
D
E
G
F
H
Ground tab
Ground groove
Ground side of connector
HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.