11 HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.
Operation
DANGER:
For outdoor use only. Never use inside a house, or other unventilated or enclosed area. This heater consumes air (oxygen). Do
not use in an unventilated or enclosed area as this will endanger your life.
DANGER:
EXPLOSION – FIRE HAZARD
□
Never store propane near high heat, open flames, pilot lights, direct sunlight, other ignition sources, or where
temperatures exceed 120°F (48°C).
□
Propane vapors are heavier than air and can accumulate in low places. If you smell gas, leave the area immediately.
□
Never install or remove propane cylinder while the heater is lit near flame, pilot lights, other ignition sources, or while the
heater is hot to the touch.
□
This heater is red hot during use and can ignite flammables too close to the burner. Keep flammables at least 2 ft. from
sides and 3 ft. from top. Keep gasoline and other flammable liquids and vapors well away from the heater.
□
The propane cylinder must always be stored outdoors in a well-ventilated space. Never store the propane cylinder in
an enclosed area (house, garage, etc). if the heater is to be stored indoors, disconnect the propane cylinder for outdoor
storage.
WARNING:
The whole gas system, hose, regulator, pilot or burner should be inspected for leaks before use.
WARNING:
Check the hose assembly for signs of extreme abrasion, cuts or wear. Suspected areas should be leak tested. If the hose leaks,
inspect the visible portion of the hose before each use of the appliance and inspect the entire hose assembly at least annually. If disassembly
is required, properly check the connections for leaks upon re-assembly. The hose assembly must be replaced prior to the appliance being
put into operation if there is evidence of excessive abrasion or wear, or if the hose is damaged. The replacement hose assembly shall be that
specified by the manufacturer.
WARNING:
Avoid twisting the flexible tubes and hoses.
WARNING:
Make sure the ventilation opening of the cylinder enclosure, control compartment, burner and circulation air passageways of the
heater are free and clear of debris. If debris, spider or insect nests are found, clean the holes with heavy-duty pipe cleaner or compressed air.
WARNING:
Always keep a dry chemical fire extinguisher readily available.
WARNING:
For safety, always allow a 5-minute complete shut off period before re-lighting a hot heater.
WARNING:
Maximum Working (kPa) Pressure: 250PSIG.
WARNING:
Do not move the heater, or cover it with a protective cover after it has been turned off until the temperature has cooled down.