background image

PULL CHAIN OPERATING INSTRUCTIONS

PULL CHAIN OPERATING INSTRUCTIONS

Attach the two pull chains and fobs (LL) to the pull chains located 
on the switch housing (I). Turn on the power and check the 
operation of the fan.

The pull chain controls the fan speed as follows:
1 pull - High, 2 pulls - Medium, 3 pulls - Low and 4 pulls - Off.

Speed settings for warm or cool weather depend on factors such 
as the room size, ceiling height, number of fans, and so on.

To turn the light kit (J) on or off, pull the chain that is attached to 
the switch housing (I).

LL

Operation

NOTE:

 

Wait for the fan to stop before reversing the direction 

of the blade rotation.

REVERSE SWITCH OPERATING INSTRUCTIONS

REVERSE SWITCH OPERATING INSTRUCTIONS

Warm weather - (Counterclockwise Direction) A downward air flow 
creates a cooling effect. This allows you to set your air conditioner 
on a warmer setting without affecting your comfort.

Cool weather - (Clockwise Direction) An upward air flow moves 
warm air off the ceiling. This allows you to set your heating unit on 
a cooler setting without affecting your comfort.

15

HAMPTONBAY.COM

Please contact 1-877-527-0313 for further assistance.

The reverse switch is located on the top of the motor housing. 
Slide the switch to the left for warm weather operation. Slide the 
switch to the right for cool weather operation.

I

J

Summary of Contents for 593-560

Page 1: ...IDE Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM EDGEWATER II 52 INCH CEILING FAN Model YG115 MWH THANK YOU THANK YOU ...

Page 2: ...luded Package Contents Installation Assembly Hanging the Fan Attaching the Fan Blades Installing the Light Kit 2 3 4 4 4 4 5 6 7 8 9 12 13 Operation Pull Chain Operating Instructions Reverse Switch Operating Instructions Care and Cleaning Troubleshooting Service Parts 15 15 15 16 16 18 Table of Contents 2 ...

Page 3: ... box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box 9 All setscrews must be checked and retightened where necessary before installation WARNING To reduce the risk of electrical shock or fire do not use this fan with any solid state fan speed control dev...

Page 4: ...ul life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty We hereby disclaim any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted ...

Page 5: ...etscrew preassembled Blade arm screw and lock washer preassembled Switch housing mounting screw preassembled Light kit mounting screw preassembled 40 watt candelabra bulb not to scale Pull chain and fob not to scale Part Part Description Description 16 3 1 2 1 1 2 10 3 3 3 2 Quantity Quantity 5 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance NOTE Hardware shown to actual size u...

Page 6: ... J K F G H Part Part A B C D E F Quantity Quantity 1 1 1 1 1 1 Quantity Quantity 5 5 1 1 1 Description Description Mounting bracket preassembled Canopy Canopy bottom cover preassembled Hanger ball downrod assembly Coupling cover Fan motor assembly PACKAGE CONTENTS PACKAGE CONTENTS Pre Installation continued 6 ...

Page 7: ...utlet box MM not included MM MM NN MM Installation MOUNTING OPTIONS MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked acceptable for fan support using the screws provided with the outlet box An outlet box commonly used for the support of lighting fixtures may not be acceptable for fan support and may need to be replaced If i...

Page 8: ...DD Assembly 8 Remove the canopy bottom cover C from the canopy B by turning the canopy bottom cover C counter clockwise Remove the mounting bracket A from the canopy B by removing the non slotted canopy mounting bracket screw DD from the bottom of the canopy B and loosening the slotted canopy mounting bracket screw DD a half turn from the screw head Next turn the canopy B counterclockwise to remov...

Page 9: ...socket Make sure the tab on the mounting bracket A socket is properly seated in the groove in the hanger ball downrod assembly D This will help to balance the ceiling fan A MM A D F 5 WARNING To reduce the risk of fire electric shock or other personal injury mount the fan only to an outlet box or supporting system marked acceptable for fan support and use the mounting screws provided with the outl...

Page 10: ...supply white neutral wire TT using a plastic wire nut BB Connect the fan motor black wire PP and the blue wire OO to the supply black hot wire SS using a plastic wire nut BB Turn the wire nut connections upward spreading them apart so the green ground wire RR will be on one side of the outlet box MM and the white QQ black PP and blue OO wires will be on the other side and push carefully up into th...

Page 11: ... mounting bracket A Secure the mounting bracket screw DD previously removed in the hole and tighten the two mounting bracket screws DD WARNING Make sure the tab on the mounting bracket A properly sits in the groove in the hanger ball downrod assembly D before attaching the canopy B to the mounting bracket A by turning the canopy housing until it drops into place NOTE Adjust the mounting bracket sc...

Page 12: ...ign objects between rotating fan blades G Attach the blades G to the blade arms H using the three blade attachment screws and rubber washers AA Start a screw and rubber washer AA into the blade arm H but do not tighten Repeat for the two remaining blade attachment screws and rubber washers AA Tighten each screw securely starting with the center screw Make sure the blade G is straight Repeat these ...

Page 13: ...ght kit to the switch housing I J F F JJ 13 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance While holding the light kit J under the fan motor assembly F locate two single white and blue wires in the switch housing labeled FOR LIGHT Make the polarized plug connections White to white Blue to black Carefully push all wires back into the switch housing I Install the light kit J ont...

Page 14: ... the fan by turning the glass shade K counterclockwise until snug DO NOT OVERTIGHTEN Restore power and your light kit is ready for opera tion 14 Finishing the light kit and attaching the glass shade K I KK LL LL J 14 CAUTION Before starting installation disconnect the power by turning off the circuit breaker or removing the fuse at the fuse box Turning power off using the fan switch is not suffici...

Page 15: ...r the fan to stop before reversing the direction of the blade rotation REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS Warm weather Counterclockwise Direction A downward air flow creates a cooling effect This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Clockwise Direction An upward air flow moves warm air off th...

Page 16: ...h WARNING Make sure the power is off at the electrical panel box before you attempt any repairs Refer to step 6 Making the electrical connections on page 10 Check the main and branch circuit fuses or breakers Check the line wire connections to the fan and switch wire connections in the switch housing Make sure all motor housing screws are snug Make sure the screws that attach the fan blade arm to ...

Page 17: ...ade Measurement deviations should be within 1 8 in Run the fan for ten minutes Use the enclosed blade balancing kit if the blade wobble is still noticeable This unit is equipped with a wattage limiting device Lamping in excess of 190 watts will disable your ceiling fan s light kit To reset your light kit you must turn the power off and relamp keeping the wattage under 190 watts Restore power to yo...

Page 18: ...itch housing Light kit Glass shade Part Part AA BB CC DD EE FF GG HH II JJ KK LL Description Description Blade attachment screw and rubber washer Plastic wire nut Balance kit Mounting bracket screw preassembled Clevis pin preassembled Cotter pin preassembled Collar setscrew preassembled Blade arm screw and lock washer preassembled Switch housing mounting screw preassembled Light kit mounting screw...

Page 19: ...uestions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM Retain this manual for future use YG115000001 Y ...