background image

 

13 

                     

                                                               

 

5ms                                                                                10ms 

2.3.5 CapsLock Status Settings 

     

                                                               

 

** CapsLock-Off                                                                  CapsLock-On 

2.3.6 Leading Key Output 

Users can scan the following programming barcode to enable HID to output a preamble message before 

outputting each piece of data, which is convenient for client as to software development and positioning. 

The key value is Ctrl+Shift+r. 

                         

                                                               

 

                      ** Disable HID Leading Key Output                      Enable HID Leading Key Output 

 

 

 

 

Summary of Contents for HBCS-2D110W

Page 1: ...2D BARCODE SCANNER WIRELESS 2 4GHz BLUETOOTH SCANNER FOR QR CODES AND LINEAR BARCODES USER MANUAL HBCS 2D110W www hamletcom com ...

Page 2: ...mlet products and to access downloads and technical support Imported by CARECA ITALIA SPA Scandiano RE Italy All trademarks and company names mentioned in this manual are used for description purpose only and remain property of their respective owners The material in this document is for information only Contents specifications and appearance of the product are indicative and may change without no...

Page 3: ...ck Status Settings 13 2 3 6 Leading Key Output 13 3 Scanning Mode 14 3 1 Manual Mode 14 3 1 1 Trigger Conditions 14 3 1 2 Decode Session Timeout 14 3 2 Command Trigger Mode 15 3 2 1 Decode Session Timeout 16 3 3 Continuous Mode 16 3 3 1 Timeout Between Decodes 16 3 3 2 Timeout between Decodes Same Barcode 17 3 3 3 Decode Session Timeout 18 3 3 4 Continuous mode key pause switch 18 3 4 Sense Mode 1...

Page 4: ...d Chip SN 34 6 Prefix Suffix 36 6 1 Prefix 36 6 2 Suffix 37 6 3 Code ID 37 6 3 1 Custom Code ID 37 6 3 2 Modify Code ID 38 6 4 Tail 40 6 5 Data Character 40 6 5 1 Date Character Interception 40 6 5 2 Modify the Length for Data 41 6 6 RF Information 41 6 7 Output Protocol 42 6 8 GS Character Replacement 42 6 9 Web address code recognition 43 7 Quick Operation 44 7 1 Fast POS Mode 44 7 2 Serial Port...

Page 5: ...65 8 3 1 QR Code 65 8 3 2 Data Matrix DM 66 8 3 3 PDF417 67 8 3 4 Mico QR 67 8 3 5 Chinese Sensible HanXin Code 67 9 Save and Cancel 68 9 1 Save 68 9 2 Cancel 68 10 Batch Setting 69 Appendix 70 Appendix A Digit Barcodes 70 0 9 70 A F 71 Appendix B Example of Parameter Settings 72 Appendix C Default Settings Table 74 Appendix D Common Serial Commands 81 Appendix E Code ID List 82 Appendix F ASCII T...

Page 6: ...figure the module function set code function After booting the function the parameter can be modified by reading one or more programming barcodes After recognizing exit programming barcode the scanning module will exit the setting mode Enter Setup Exit Setup Enable and disable the output of set code content Transmit Programming Barcode Data Do Not Transmit Programming Barcode Data Note The optionm...

Page 7: ... use the Restore Factory Defaults function with caution 1 3 User Default Settings In addition to the factory reset users can save frequently used settings as user defaults By reading Save as Custom Defaults you can save the current device configuration as user default information so that you can make quick settings when needed The default settings saved by the user can be restored by reading Resto...

Page 8: ...Simultaneous Output Mode by reading the programming barcode When users switch communication mode it is necessary to wait for the device initialization to complete before performing related operations Note1 When the module is set as USB Virtual Serial Port and communicates with the host through this port the corresponding driver needs to be installed in the host Note1 The USB HID uses 2 numbers to ...

Page 9: ... module are TTL level signals TTL 232 can be used for most application architectures For those requiring RS 232 an external conversion circuit is needed The default serial communication parameters of the scanning module are as follows When they are inconsistent with the host device they can be modified by reading the programming barcode Default communication parameters of TTL 232 Parameter Default...

Page 10: ...10 1200bps 4800bps 9600bps 14400bps 19200bps 38400bps 57600bps 115200bps 2 2 2 Parity Methods There are 3 alternative parity methods as follows None ...

Page 11: ...ning and decoding a barcode the device would send the following input message Data reception Bit Byte 7 6 5 4 3 2 1 0 0 Message ID 0x02 1 Bar Code Data Length 2 Fixed Value 0x5d 3 Fixed Value 0x51 4 Fixed Value 0x31 5 60 Barcode Data 61 Barcode Data 62 Fixed Value 0x51 63 0x01 followed by packets 0x0 followed by no packets 2 3 2 Access Cycle of PC to HID Device You can modify the access period of ...

Page 12: ...that is the timeout from valid message to release message The timeout is from 1ms to 63ms 1ms 2ms 5ms 10ms 2 3 4 Timeout After HID Release After reading the following programming barcode you can modify the timeout after the HID is released that is the timeout from the release of the message to the next valid message The timeout is from 1ms to 63ms 1ms 2ms ...

Page 13: ... Users can scan the following programming barcode to enable HID to output a preamble message before outputting each piece of data which is convenient for client as to software development and positioning The key value is Ctrl Shift r Disable HID Leading Key Output Enable HID Leading Key Output ...

Page 14: ...l triggering and level triggering FEdge triggering refers to the detection of the level pulse of the trigger signal that is start reading and the reading is ended when the reading is successful or the decode session timeout condition is reached F The Level Trigger condition refers to the level at which the trigger signal needs to be held during the start of reading to the end of reading When the t...

Page 15: ...hrough the communication interface and stop reading If a new reading is to be booted the trigger command needs to be resent If the reading exceeds the length of a single reading in time duration the reading will be stopped Command Trigger Mode Note In the command trigger mode the serial command of the trigger signal is 7E 00 08 01 00 02 01 AB CD After receiving the scan commands the serial port re...

Page 16: ...to pause continuous reading or continue reading continuously In continuous reading it is necessary to maintain the trigger level of 50ms or more and then cancel it so that the reading will be suspended When the reading state is suspended the trigger level of 50ms or more is also maintained and then canceled and the reading is continued Continuous Mode 3 3 1 Timeout Between Decodes It refers to the...

Page 17: ...e same barcode Timeout between Decodes Same Barcode means that the same barcode will not be read if it has been scanned within the set timeout It can only be read and output beyong the timeout By default Timeout between Decodes Same Barcode is turned off ON OFF Scan the following programming barcode to set Timeout between Decodes Same Barcode Setting range 0ms 12700ms FNote The delay time setting ...

Page 18: ... pause is not supported is set the key is invalid for continuous mode The user can set the continuous mode key pause switch through the following setting code Continuous mode key pause supports Continuous mode key pause is not 3 4 Sense Mode Sense Mode refers to a working mode in which the scanning module conducts reading by sensing the change in brightness of the surrounding environment When the ...

Page 19: ...t For the setting of decode session timeout please refer to the programming barcode in Section 3 1 2 Decode Session Timeout to set 3 4 2 Timeout between Decodes For the setting of the timeout between decodes please refer to the programming barcode in Section 3 2 1 Timeout between Decodes to set 3 4 3 Timeout between Decodes Same Barcode For setting Timeout between Decodes Same Barcode please refer...

Page 20: ...or which the scanning module that detects the scene change needs to wait for the image to stabilize before reading the code in the inductive scanning module The settting range of image stabilization timeout is 0 25500 ms and the step size is 100ms The default image stabilization timeout is 400ms 0ms 100ms 400ms 1000ms 2000ms ...

Page 21: ...on FFill Light always OFF the fill light does not light up in any cases Fill Light ON when Photographing Fill Light always ON Fill Light always OFF 4 2 Positioning The scanning module has an auxiliary device for positioning which projects a pointing line during shooting to remind users of reading the center of the scene image captured by the module F Positioning Light ON when Photographing the pos...

Page 22: ...g Light always OFF the positioning light does not illuminate in any cases Positioning Light ON when Photographing Positioning light always ON when Photographing Positioning Light always ON Positioning Light always OFF ...

Page 23: ...set the drive frequency of the passive buzzer Passive Buzzer Passive_Low Frequency Passive_Intermediate Frequency Passive_High Frequency 5 2 2 Active Buzze Scan the following programming barcodes to set the buzzer as active one and set the active buzzer s operating level Scan High Level the buzzer is set to active low when idle and active high level when working scan Low Level the buzzer is set to...

Page 24: ...arcodes to enable disable the programming barcode beep Beep for Programming Barcode_ON Beep for Programming Barcode _OFF 5 4 Startup Beep When the scanning module is on after power on the scanning module can output or turn off the startup beep according to the setting requirements Startup Beep_ON Startup Beep_OFF ...

Page 25: ...d LED are used for prompting These signals can be turned off if the user requires to do so Good Read LED_ON Good Read LED_OFF Good Read Beep_ON Good Read Beep_OFF The user can set the timeout of Good Read Beep by reading the following programming barcodes 30ms 60ms 90ms 120ms 5 6 Data Output Encoding Format Users can set the output format of the scanning module through the following programming ba...

Page 26: ...or Word and input box of common chat tool The Original Data output is used to encrypt the serial output of the data GBK UTF8 Original Data UNICODE 5 7 Different Country Keyboard Settings In order to apply it in different countries the device can be set as the corresponding keyboard of each country by the following programming barcodes US Czech ...

Page 27: ...order to apply it in more regional application environments the standard virtual keyboard output settings can be made by reading the following programming barcodes But that will cause a certain loss in output efficiency Note that when using a virtual keyboard you must ensure that the keypad number keys are enabled ...

Page 28: ...can be escaped as a control function key When the virtual keyboard is enabled other HID Keyboard of the module is set as default value the input operation of the control function key is as follows Please refer to the control character correspondence table for the corresponding relationship between the specific ASCII value and the control function key 1 Virtual keyboard Ctrl Mode on Read the charac...

Page 29: ...corresponding control character operation is ALT Character corresponds to ASCII decimal value For example for HT characters the scanning module virtual keyboard operation is as follows Enter Alt 0 9 the virtual keyboard would hold down Alt then press 0 and 9 of the numeric keypad and finally release Alt When the standard keyboard outputs the control character output function is turned off and ASCI...

Page 30: ... 0A DownArrow Ctrl J Justify VT 0B Vertical Tab Ctrl K hyperlink FF 0C Delete Ctrl L list left align CR 0D Enter Ctrl M SO 0E Insert Ctrl N New SI 0F Esc Ctrl O Open DLE 10 F11 Ctrl P Print DC1 11 Home Ctrl Q Quit DC2 12 PrintScreen Ctrl R DC3 13 Backspace Ctrl S Save DC4 14 tab shift Ctrl T NAK 15 F12 Ctrl U SYN 16 F1 Ctrl V Paste ETB 17 F2 Ctrl W CAN 18 F3 Ctrl X EM 19 F4 Ctrl Y SUB 1A F5 Ctrl Z...

Page 31: ...keyboard The user can turn on and off the digital output function of the analog keypad by reading the following setting codes Keypad Numeric Output On Keypad Numeric Output Off 5 10 2 Output of keypad operator function If this function is not turned on all outputs would be output according to the corresponding key value of the large keyboard After this function is turned on only _ in the decoded d...

Page 32: ...rios special barcodes for black and white inversion need to be enabled The user can enable disable the reading function of inverse video code by reading the following programming barcodes Video Reverse OFF Video Reverse ON 5 13 Invoicing mode In order to facilitate the use of this module in the billing system users can configure the billing mode by reading the setting code and realize the format c...

Page 33: ...th the WSM billing assistant 5 14 Read Device Version Information Users can quickly obtain the current device version information and all the device version information by reading the following setting codes Read device version information Read all device version information 5 15 Write Read Device ID Users can read and write ID through serial port or virtual serial port The ID information include ...

Page 34: ...ID WSM1605 FID WSM2020 Read ID Serial port sending ReadDeviceID Serial port return SN 20200508 MID WSM1605 FID WSM2020 Note 1 The instruction is followed by as the closing mark 2 When SN FID MID are not written read the DeviceID of the device and return SN NULL MID NULL FID NULL 3 If the write instruction ID data does not meet the requirements or the instruction format is wrong send a write instru...

Page 35: ...35 Read chip SN number ...

Page 36: ...ssed output data format Prefix Code ID Data Suffix Tail 6 1 Prefix Prefix is a string of strings defined by the user before the data is decoded The user can add and modify the prefixes by reading the following programming barcodes Enable Prefixes Disable Prefixes Scan the following programming barcode with the programming barcode of Digit Barcodes and the programming barcode of save the user can m...

Page 37: ...amming barcode of save the user can modify the suffixes Modify Suffix Note A suffix has 15 characters at most and two hexadecimal values is for a prefix character Refer to Appendix F for the hexadecimal conversion table of character values 6 3 Code ID 6 3 1 Custom Code ID Code ID uses one character Users can customize Code ID by reading the following programming barcodes to identify different barc...

Page 38: ...y the Code ID corresponding to each barcode by reading the following programming barcodes Modify EAN13 Code ID Modify EAN8 Code ID Modify UPC A Code ID Modify UPC E0 Code ID Modify UPC E1 Code ID Modify Code 128 Code ID Modify Code 39 Code ID Modify Code 93 Code ID ...

Page 39: ...odify Interleaved 2 of 5 Code ID Modify Industrial 25 Code ID Modify Matrix 2 of 5 Code ID Modify Code11 Code ID Modify MSI Code ID Modify RSS Code ID Modify RSS Limited Code ID Modify RSS Expanded Code ID Modify QR Code Code ID ...

Page 40: ...0x09 CRLF Tail 0x0D 0x0A 6 5 Data Character 6 5 1 Date Character Interception This function is used in scenarios where the user needs to output partial decoded information The decoding information Data consists of three parts Start Center End The user can select some of the information that needs to be output by reading the following programming barcodes ...

Page 41: ... a hexadecimal character for their length The characters which are corresponding to the hexadecimal conversion table can be found in Appendix F Modify the Length for Start Data Modify the Length for End Data 6 6 RF Information The Scan Fail RF information is the output information after the scanning module fails to scan the codes so that the user or the program can adjust or operate after detectin...

Page 42: ...l port mode The format of the decoding result with the protocol output is 03 length decoded data Note The protocol mode must adopt UTF 8 encoding output format In other output encoding formats only raw data can be output regardless of whether the output with protocol is selected Raw Data With Protocol 6 8 GS Character Replacement GS as a group separator was applied to the bar code of the European ...

Page 43: ...he Save setting code GS Character Replacement Enable GS Character Replacement Disable Read the following setting codes cooperate with the data code setting code and the save setting code and the user can modify GS replacement characters GS Alternate Character Modification 6 9 Web address code recognition Read the following setting codes and you can set the permission and prohibition of the website...

Page 44: ...ng device to work in POS Mode by reading the following programming barcode Fast POS Mode 7 2 Serial Port Full Codes On Mode In order to facilitate the quick configuration and switch to the serial port and full codes open mode during the secondary development process you can realize the quick configuration function by reading the following programming barcodes Serial Port Full Codes ON ...

Page 45: ... The user can enable disable the commodity barcode check digit output by reading the following programming barcode commodity barcode includes EAN13 EAN8 UPC A UPC E0 UPC E1 Enable Transmit Check Digit Disable Transmit Check Digit 8 1 3 Enhancement of literacy Enabling and disabling bar code reading ability enhancement can be carried out by reading the following setting codes After the ability to r...

Page 46: ...ing the following programming barcodes Enable EAN13 Disable EAN13 2 Enable or Disable Add On Code The user can enable and disable the forced output function of EAN13 add on code by reading the following programming barcodes EAN13 Add On Code Required EAN13 Add On Code Not Required The user can enable and disable the configuration of the EAN13 add on code by reading the following programming barcod...

Page 47: ...ssion of EAN13 Parity Bits Disable Transmission of EAN13 Parity Bits 8 2 2 EAN 8 1 Enable or Disable EAN8 The user can enable and disable the EAN8 barcode reading function by reading the following programming barcodes Enable EAN8 Disable EAN8 2 Enable or Disable Add On Code The user can enable and disable the forced output function of EAN8 add on code by reading the following programming barcodes ...

Page 48: ...8 2 Digit Add On Code Enable EAN8 5 Digit Add On Code Disable EAN8 5 Digit Add On Code 3 Check bit Output Function Enable and Disable Enable Transmission of EAN8 Parity Bits Disable Transmission of EAN8 Parity Bits 8 2 3 UPC A 4 1 Enable or Disable UPC A The user can scan and disable the UPC A barcode reading function by reading the following programming barcodes Enable UPC A Disable UPC A 2 Enabl...

Page 49: ...the UPC A add on code by reading the following programming barcodes Enable UPC A 2 Digit Add On Code Disable UPC A 2 Digit Add On Code Enable UPC A 5 Digit Add On Code Disable UPC A 5 Digit Add On Code 3 Enable Conversion from UPC A to EAN13 The user can enable disable the conversion of UPC A to EAN13 by reading the following programming barcodes Enable UPC A to EAN13 Disable UPC A to EAN13 5 Chec...

Page 50: ...le or Disable Add On Code The user can enable and disable the forced output function of UPC E0 add on code by reading the following programming barcodes UPC E0 Add On Code Required UPC E0 Add On Code Not Required The user can enable and disable the configuration of the UPC E0 add on code by reading the following programming barcodes Enable UPC E0 2 Digit Add On Code Disable UPC E0 2 Digit Add On C...

Page 51: ...wing programming barcodes Enable UPC E1 Disable UPC E1 2 Enable or Disable Add On Code The user can enable and disable the forced output function of UPC E1 add on code by reading the following programming barcodes UPC E1 Add On Code Required UPC E1 Add On Code Not Required The user can enable and disable the configuration of the UPC E1 add on code by reading the following programming barcodes Enab...

Page 52: ... can enable and disable the Code128 barcode reading function by reading the following programming barcodes Enable Code128 Disable Code128 2 Set Length Range for Code128 Users can set the minimum and maximum length of Code128 by reading the following programming barcodes Set the Minimum Length for Code128 to 0 Set the Minimum Length for Code128 to 4 Set the Maximum Length for Code128 to 32 Set the ...

Page 53: ...wing programming barcodes Enable Code39 Disable Code39 2 Set Length Range for Code39 Users can set the minimum and maximum length of Code39 by reading the following programming barcodes Set the Minimum Length for Code39 to 0 Set the Minimum Length for Code39 to 4 Set the Maximum Length for Code39 to 32 Set the Maximum Length for Code39 to 255 3 Transmit Start Stop Character The user can set the ou...

Page 54: ...following programming barcodes Support Code32 Mode Disable Support Code32 Mode Users can choose whether Code 32 outputs the prefix A by reading the following programming barcodes the output of Code 32 prefix A Disable output of Code 32 prefix A 5 FullAsc Mode Users can choose whether Code39 supports FullAsc mode by reading the following programming barcodes Support FullAsc Mode Disable Support Ful...

Page 55: ...ng codes Code39 Outputs Parity Bits Code39 Does Not Output Parity Bits 8 2 8 Code93 1 Enable or Disable Code93 The user can enable and disable the Code93 barcode reading function by reading the following programming barcodes Enable Code93 Disable Code93 2 Set Length Range for Code93 Users can set the minimum and maximum length of Code93 by reading the following programming barcodes Set the Minimum...

Page 56: ...Bar Disable CodaBar 2 Set Length Range for CodaBar Users can set the minimum and maximum length of CodaBar by reading the following programming barcodes Set the Minimum Length for CodaBar to 0 Set the Minimum Length for CodaBar to 4 Set the Maximum Length for CodaBar to 32 Set the Maximum Length for CodaBar to 255 3 Transmit Start Stop Character The user can set the output of CodaBar Start Stop Ch...

Page 57: ...The user can set the output of CodaBar check bits by reading the following setting codes CodaBar Parity Bit Output CodaBar Parity Bit Not Output 8 2 10 Interleaved 2 of 5 1 Enable or Disable Interleaved 2 of 5 The user can enable and disable the Interleaved 2 of 5 barcode reading function by reading the following programming barcodes Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 2 Set Lengt...

Page 58: ...leaved 2 of 5 Verification Format Mod10 Interleaved 2 of 5 Verification Format NONE 4 Parity Bit Output Setting The user can set whether Interleaved 2 of 5 outputs check bits by reading the following setting code Interleaved 2 of 5 Outputs Parity Bits Interleaved 2 of 5 Does Not Output Parity Bits 8 2 11 Industrial 25 1 Enable or Disable Industrial 25 The user can enable and disable the Industrial...

Page 59: ...e Maximum Length to 32 Set the Maximum Length to 255 3 Verify Format Setting The user can set whether Industrial 25 processes verification by reading the following setting code Industrial 25 Verification Format Mod10 Industrial 25 Verification Format NONE 4 Parity Bit Output Setting The user can set whether Industrial 25 outputs check bits by reading the following setting code Industrial 25 Output...

Page 60: ... of Matrix 2 of 5 by reading the following programming barcodes Set the Minimum Length to 0 Set the Minimum Length to 4 Set the Maximum Length to 32 Set the Maximum Length to 255 3 Verify Format Setting The user can set whether Matrix 2 of 5 processes verification by reading the following setting code Matrix 2 of 5 Verification Format Mod10 Matrix 2 of 5 Verification Format NONE 4 Parity Bit Outpu...

Page 61: ... Enable Code11 Disable Code11 2 Set Length Range for Code11 Users can set the minimum and maximum length of Code11 by reading the following programming barcodes Set the Minimum Length for Code11 to 0 Set the Minimum Length for Code11 to 4 Set the Maximum Length for Code11 to 32 Set the Maximum Length for Code11 to 255 3 Setting of Check Format The user can set the check format of Code11 by reading...

Page 62: ...nable MSI Plessey Disable MSI Plessey 2 Set Length Range for MSI Plessey Users can set the minimum and maximum length of MSI Plessey by reading the following programming barcodes Set the Minimum Length for MSI Plessey to 0 Set the Minimum Length for MSI Plessey to 4 Set the Max Length for MSI Plessey to 32 Set the Max Length for MSI Plessey to 255 3 Verify Format Setting The user can set whether M...

Page 63: ...an enable and disable the RSS 14 barcode reading function by reading the following programming barcodes Enable RSS 14 Disable RSS 14 2 AI output enable and disable The user can set whether RSS 14 barcode AI is output by reading the following setting codes RSS 14 AI Output with Parentheses RSS 14 AI Output Without Parentheses 8 2 16 RSS Limited 1 Enable or Disable RSS Limited The user can enable an...

Page 64: ...es RSS Limited AI Output with Parentheses RSS Limited AI Output Without Parentheses 8 2 17 RSS Expanded 1 Enable or Disable RSS Expanded The user can enable and disable the RSS Expanded barcode reading function by reading the following programming barcodes Enable RSS Expanded Disable RSS Expanded 2 Set Length Range for RSS Expanded Set the Minimum Length to 0 Set the Minimum Length to 4 ...

Page 65: ...tput with Parentheses RSS Expanded AI Output Without Parentheses 8 3 Operation of 2D Symbologies 8 3 1 QR Code 1 Enable or Disable QR Code The user can enable and disable the QR Code barcode reading function by reading the following programming barcodes Enable QR Disable QR 2 Enable or Disable QR Mode1 The user can enable and disable the QR Mode1 reading function by reading the following programmi...

Page 66: ... codes QR Prefix 11 On QR Prefix 11 Off 8 3 2 Data Matrix DM The user can enable and disable the Data Matrix reading function by reading the following programming barcodes Enable DM Disable DM The user can enable and disable simultaneous multiple DM code reading function by reading the following programming barcodes Enable Multiple DM Disable Multiple DM ...

Page 67: ... user can enable and disable the Mico QR barcode reading function by reading the following programming barcodes Enable Mico QR Disable Mico QR 8 3 5 Chinese Sensible HanXin Code The user can enable and disable the Chinese Sensible HanXin Code reading function by reading the following programming barcodes Enable Chinese Sensible HanXin Code Disable Chinese Sensible HanXin Code ...

Page 68: ...ed data the following programming barcode can be scanned to cancel the current setting also one bit of data which is previous scanned and a string of data which is previous scanned Cancel the Last Digit Cancel All Digits Cancel Current Setting Note Cancelling the current setting means cancelling all the Digit Barcodes that were scan and reset shall be conducted after canceling ...

Page 69: ...taneously 5 The setting content conforming to the batch processing setting code format is made into QR code in the code making software and the setting code is read for batch setting For example The programming barcodes of Enter Setup parameter 00000000 Sense Mode parameter 02000003 Positioning Light ON when Photographing parameter 03000000 Decode Session Timeout 3000ms parameter 0202001E and Disa...

Page 70: ...70 Appendix Appendix A Digit Barcodes 0 9 0 1 2 3 4 5 6 7 ...

Page 71: ...71 8 9 A F A B C D E F ...

Page 72: ...odify Suffix programming barcode 4 Read the Digit Barcodess of 4 4 4 1 5 4 4 1 5 Read the programming barcode of Save Example 3 Modify EAN13 Code ID to A 1 Query the character table to obtain the hexadecimal value corresponding to the A character 41 2 Read Enter Setup If it has been enabled you can skip this step 3 Read the the programming barcode of Modify EAN13 Code ID 4 Read the Digit Barcodess...

Page 73: ...234567890ABC1234567890 the middle 3 bytes ABC shall be output 1 Query the character table to obtain the hexadecimal value corresponding to the 10 character 0A 2 Read Enter Setup If it has been enabled you can skip this step 3 Read the programming barcode of Modify the Length for End Data 4 Read the Digit Barcodess of 0 A in turn 5 Read the programming barcode of Save 6 Read the programming barcode...

Page 74: ...acter Modification 5 Read the data codes 4 and 4 in turn 6 Read the programming barcode of Save Appendix C Default Settings Table Parameter Default Setting Remarks Programming Barcode Function of Programming Barcode Enter Communication Settings Communication Mode USB HID TTL 232 Serial Port Baud Rate 9600bps Serial Parity Bits None Range 1 64ms Serial Data Bits 8 Range 1 63ms Serial Port Stop 1 Ra...

Page 75: ...B CD Trigger command response allowed Decode Session Timeout 5000ms Range 100ms 25500ms Step size 100ms 0x00 Infinite Continuous Mode Timeout between Decodes 1000ms Range 0 25500ms Step size 100ms Timeout between Decodes Same Barcode OFF Delay time range 100ms 25500ms Step size 100ms 0x00 Infinite Decode Session Timeout 5000ms Range 100 25500ms Step size 100ms 0x00 infinit Continuous mode key paus...

Page 76: ...en Photographing Fill Light ON when Photographing Buzzer Buzzer Setting Passive Buzzer Passive Buzzer Intermediate Frequency Active Buzzer High level Active high when working Active low when idle Mute OFF Setup Beep ON Good Read Beep ON Timeout of Good Read Beep 60ms Range 0 255ms Good Read LED ON Good Read Beep of Programming Barcode ON Data Output Encoding Format GBK Keyboard US Virtual Standard...

Page 77: ...acement Disable Web address code recognition Enable Code Setting Inverse Video Disable Image Mirror Flip Disable Product Barcode Check Digit Enable EAN13 EAN8 UPC A UPC E0 UPC E1 Enhancement of literacy Disable EAN 13 Read Enable Add On Code Not Required 2 Digit Add On Code Disable 5 Digit Add On Code Disable Parity Bit Output Enable EAN 8 Read Enable Add On Code Not Required 2 Digit Add On Code D...

Page 78: ...Add On Code Not Required 2 Digit Add On Code Disable 5 Digit Add On Code Disable Parity Bit Output Enable UPC E1 Read Enable Add On Code Not Required 2 Digit Add On Code Disable 5 Digit Add On Code Disable Parity Bit Output Enable Code128 Read Enable Set the Minimum Length 0 Set the Maximum Length 255 Add Prefix 11 On off Code 39 Read Enable Set the Minimum Length 0 Set the Maximum Length 255 ...

Page 79: ...Length 0 Set the Maximum Length 255 CodaBar Read Enable Set the Minimum Length 0 Set the Maximum Length 255 Start Stop Character Disable Interleaved 2 of 5 Read Disable Set the Minimum Length 4 Set the Maximum Length 32 Verify Format None Parity bit output Disable Industrial 25 Read Disable Set the Minimum Length 4 Set the Maximum Length 32 Verify Format None Parity bit output Disable Matrix 2 of ...

Page 80: ... bit output Disable MSI Plessey Read Disable Set the Minimum Length 4 Set the Maximum Length 32 Verify Format Single Mod10 Parity bit output Disable RSS 14 Read Disable AI Output with Parentheses with Parentheses RSS Limited Read Disable AI Output with Parentheses with Parentheses RSS Expanded Read Disable Set the Minimum Length 4 Set the Maximum Length 32 AI Output with Parentheses with Parenthes...

Page 81: ...0 08 01 00 02 01 02 DA 02 00 00 01 00 33 31 Trigger command response allowed 7E 00 08 01 00 01 04 07 2C 02 00 00 01 00 33 31 Trigger command response disable 7E 00 08 01 00 01 84 96 A4 02 00 00 01 00 33 31 Timeout between Decodes 5s 7E 00 08 01 00 05 32 9D 7D 02 00 00 01 00 33 31 Decode Session Timeout 10s 7E 00 08 01 00 05 64 A7 4E 02 00 00 01 00 33 31 Set baud rate 115200bps 7E 00 08 02 00 2A 1A...

Page 82: ...de 128 j 0x96 Code 39 b 0x97 Code 93 i 0x98 Codabar a 0x99 Interleaved 2 of 5 e 0x9A Industrial 2 of 5 D 0x9B Matrix 2 of 5 v 0x9C Code 11 H 0x9D MSI Plessey m 0x9E GS1 Databar RSS 14 R 0x9F GS1 Databar RSS Limited R 0xA0 GS1 Databar RSS Expanded R 0xA1 QR Code Q 0xA2 Data Matrix u 0xA3 PDF 417 r 0xA4 Mico QR X 0xA5 Chinese Sensible HanXin Code h 0xA6 ...

Page 83: ...K Acknowledgment 07 7 BEL Bell 08 8 BS Backspace 09 9 HT Horizontal Tab 0a 10 LF Line Feed 0b 11 VT Vertical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF Device Control 3 14 20 DC4 Device Control 4 15 21 NAK Negative Acknowledgment 16 22 SYN Synchronous Idle ...

Page 84: ...e 30 RS Request to Send 1f 31 US Unit Separator 20 32 SP Space 21 33 Exclamation Mark 22 34 Double Quote 23 35 Number Sign 24 36 Dollar Sign 25 37 Percent 26 38 Ampersand 27 39 Single Quote 28 40 Right Closing Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward Slash 30 48 0 31 49 1 32 50 2 ...

Page 85: ...38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 Less Than 3d 61 Equal Sign 3e 62 Greater Than 3f 63 Question Mark 40 64 AT Symbol 41 65 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N ...

Page 86: ... 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 Left Opening Bracket 5c 92 Back Slash 5d 93 Right Closing Bracket 5e 94 Caret Circumflex 5f 95 _ Underscore 60 96 Grave Accent 61 97 a 62 98 b 63 99 c 64 100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j ...

Page 87: ...109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 Left Opening Brace 7c 124 Vertical Bar 7d 125 Right Closing Brace 7e 126 Tilde 7f 127 DEL Delete ...

Page 88: ...s 010209C4 4800bps 01020271 9600bps 01020139 14400bps 010200D0 19200bps 0102009C 38400bps 0102004E 57600bps 01020034 115200bps 0102001A NONE Parity 01030000 ODD Parity 01030001 EVEN Parity 01030002 Access Cycle of PC to HID Device 1ms 01040001 For other durations the last two parameters can be modified Access Cycle of PC to HID Devic 3ms 01040003 Access Cycle of PC to HID Devic5ms 01040005 Access ...

Page 89: ...Session Timeout 1000ms 0202000A For other durations the last two parameters can be modified Decode Session Timeout 3000ms 0202001E Decode Session Timeout 5000ms 02020032 Decode Session Timeout 10000ms 02020064 Decode Session Timeout Infinite 02020000 Command Trigger Mode 02000001 Continuous Mode 02000002 Trigger command response allowed 020A0001 Trigger command response disable 020A0000 Continuous...

Page 90: ... 1000ms 0207000A Timeout between Decodes Same Barcode 3000ms 0207001E Timeout between Decodes Same Barcode 5000ms 02070032 Sense Mode 02000003 Medium Sensitivity 0209640A Low Sensitivity 020932A0 High Sensitivity 0209320A Enhanced Sensitivity 02093205 Image Stabilization Timeout 0ms 02080000 For other durations the last two parameters can be modified Image Stabilization Timeout 100ms 02080001 Imag...

Page 91: ...2 Active Buzzer 04010006 Active Buzzer High Level 04010003 Active Buzzer Low Level 04010004 Beep for Programming Barcode_ON 04020000 Beep for Programming Barcode _OFF 04020001 Startup Beep_ON 04030000 Startup Beep_OFF 04030001 Good Read LED_ON 04040000 Good Read LED_OFF 04040001 Good Read Beep_ON 04040002 Good Read Beep_OFF 04040003 Timeout of Good Read Beep 30ms 0404011E For other durations the l...

Page 92: ...d Italy 04060005 Keyboard Japan 04060006 Keyboard Spain 04060007 Keyboard Turkey Q 04060008 Keyboard Turkey F 04060009 Keyboard Mexico Latin America 0406000A Standard Keyboard 04070000 Virtual Keyboard 04070001 Virtual Keyboard_Ctrl Mode 04070010 Virtual Keyboar_Alt Mode 04070011 Virtual Keyboar_Control Character Output Off 04070012 Image Mirroring Mode ON 04080000 Image Mirroring Mode OFF 0408000...

Page 93: ...de ID 05020000 Disable Code ID 05020001 Restore Default Code ID 05020002 Modify EAN13 Code ID 05030000 Modify EAN8 CODE ID 05030001 Modify UPC A CODE ID 05030002 Modify UPCE0 CODE ID 05030003 Modify UPCE1 CODE ID 05030004 Modify CODE128 CODE ID 05030005 Modify CODE39 CODE ID 05030006 Modify CODE93 CODE ID 05030007 Modify CodaBar CODE ID 05030008 Modify Interleaved 2 of 5 CODE ID 05030009 Modify In...

Page 94: ... Data 05050000 Tansmit the Start Data 05050001 Tansmit the END Data 05050002 Tansmit the Center Data 05050003 Modify the Length for Start Data 05050004 Modify the Length for End Data 05050005 Enable Transmitting RF Information 05060000 Disable Transmitting RF Information 05060001 Modify RF Information 05060002 Raw Data 05070000 With Protocol 05070001 GS Character Replacement Enable 050A0000 GS Cha...

Page 95: ...t Required 07011100 Enable EAN13 2 Digit Add On Code 07012000 Disable EAN13 2 Digit Add On Code 07012100 Enable EAN13 5 Digit Add On Code 07013000 Disable EAN13 5 Digit Add On Code 07013100 Enable Transmission of EAN13 Parity Bits 07014000 Disable Transmission of EAN13 Parity Bits 07014100 Enable EAN8 07020000 Disable EAN8 07020100 EAN8 Add On Code Required 07021000 EAN8 Add On Code Not Required 0...

Page 96: ... Enable UPC A to EAN13 05080000 Disable UPC A to EAN13 05080001 Enable UPC E0 07040000 Disable UPC E0 07040100 UPC E0 Add On Code Required 07041000 UPC E0 Add On Code Not Required 07041100 Enable UPC E0 2 Digit Add On Code 07042000 Disable UPC E0 2 Digit Add On Code 07042100 Enable UPC E0 5 Digit Add On Code 07043000 Disable UPC E0 5 Digit Add On Code 07043100 Enable Transmission of UPC E0 Parity ...

Page 97: ... to 255 070611FF Code128 Prefix 11 On 07062000 Code128 Prefix 11 Off 07062100 Enable Code39 07070000 Disable Code39 07070100 Set the Minimum Length for Code39 to 0 07071000 For other durations the last two parameters can be modified Set the Minimum Length for Code39 to 4 07071004 Set the Maximum Length for Code39 to 32 07071120 Set the Maximum Length for Code39 to 255 070711FF Output of Code39 Sta...

Page 98: ...000 Disable Codabar 07090100 Set the Minimum Length for Codabar to 0 07091000 For other durations the last two parameters can be modified Set the Minimum Length for Codabar to 4 07091004 Set the Maximum Length for Codabar to 32 07091120 Set the Maximum Length for Codabar to 255 070911FF Output of CodaBar Start Stop Character 07092000 Disable Output of CodaBar Start Stop Character 07092100 CodaBar ...

Page 99: ...ial 25to 4 070B1004 Set the Maximum Length for Industrial 25to 32 070B1120 Set the Maximum Length for Industrial 25to 255 070B11FF Industrial 25Verification Format Mod10 070B2000 Industrial 25Verification Format NONE 070B2100 Industrial 25Outputs Parity Bits 070B3000 Industrial 25Does Not Output Parity Bits 070B3100 Enable Interleaved 2 of 5 070C0000 Disable Interleaved 2 of 5 070C0100 Set the Min...

Page 100: ...070E1000 For other durations the last two parameters can be modified Set the Minimum Length for MSI Plessey to 4 070E1004 Set the Maximum Length for MSI Plessey to 32 070E1120 Set the Maximum Length for MSI Plessey to 255 070E11FF MSI Plessey Verification Format Single Mod10 070E2000 MSI Plessey Verification Format Double Mod10 070E2100 MSI Plessey Outputs Parity Bits 070E3000 MSI Plessey Does Not...

Page 101: ... RSS to 255 070F31FF Enable QR 07140000 Disable QR 07140100 Enable QR Mode1 07141000 Disable QR Mode1 07141100 QR Prefix 11 On 07142000 QR Prefix 11 Off 07142100 Enable DM 07150000 Disable DM 07150100 Enable Multiple DM 07151000 Disable Multiple DM 07151100 Enable PDF417 07160000 Disable PDF417 07160100 Enable Mico QR 07190000 Disable Mico QR 07190100 Enable Chinese Sensible HanXin Code 07170000 D...

Page 102: ...102 1 08010001 2 08010002 3 08010003 4 08010004 5 08010005 6 08010006 7 08010007 8 08010008 9 08010009 A 0801000A B 0801000B C 0801000C D 0801000D E 0801000E F 0801000F ...