i-H-LED-STAT-1002 Rev A
LEDstat 100W Dimmer Module
The device is designed for single-phase installation, and must be installed in accordance with applicable UK
and European standards. The device should be connected according to the connection diagram (diagram 2)
in this operating manual. Installation, connection, and setup should be carried out by a qualified electrician.
DO NOT disassemble device as it may cause an electric shock and will invalidate the guarantee. Before
installation, ensure the mains power is isolated and connection cables are not live.
For technical support contact us via:
Post: Hamilton Litestat Customer Services, Quarry Industrial Estate Mere, Wiltshire, BA12 6LA.
Web:
IMPORTANT – PLEASE READ BEFORE INSTALLATION:
Connection (Diagram 2).
1. Isolate the mains supply.
2. Remove the retaining screws and
carefully withdraw accessory from wall
box to reveal connections at rear.
3. Check that no mains voltage is present
within existing accessory by use of 240
volt test-lamp (if available).
4. Disconnect all cables noting their
respective connections.
5. Bend back the top and bottom wall box
mounting lugs if present.
6. Ensure the wall box is free from dust and
debris.
7. Connect accessory – see connection
Diagram 2.
8. Check all connections thoroughly.
9. Mount accessory, taking care not to trap
any cables beneath plate fixing screws.
Do not over-tighten the fixing screws.
This may cause damage which could
invalidate the warranty.
10. Switch on mains supply at fuse box and
check operation of accessory.
Model : H-LED-STAT
SW
LED-STAT
LIVE IN
NEUTRAL
230-240V AC Mains 50Hz
LIVE OUT TO LOAD
1-WAY DIMMING
L L1
LED
LOAD
SW
LED-STAT
LIVE IN
NEUTRAL
LIVE OUT TO LOAD
2 OR 3 WAY DIMMING
MAINS RATED PUSH TO MAKE
OR RETRACTIVE SWITCHES
L L1
LED
LOAD
NUMBER OF DIMMER
SWITCHES PER PLATE
NOMINAL PLATE
SIZE (MM)
LOADING PER PLATE
1
88 X 88
88 X 88
86 X 146
86 X 146
100W
200W
300W
400W
2
3
4
Loading:
The LEDstat intelligent dimmer can control up to 100W of the following lighting types:
Incandescent lamps.
Mains halogen.
Mains directly dimmable LED lamps.
Mains directly dimmable CFL lamps.
Dimmable LV electronic transformers.
Number of
dimmer switches
per plate
Nominal plate size
(mm)
MAX Loading per
plate
(Trailing Edge)
MAX Loading per
plate (Leading
Edge) -25%
1
2
3
4
88 x 88
88 x 88
86x 146
86 x 146
100W
200W
300W
400W
75W
150W
225W
300W