![Hamilton Manufacturing Corporation Audit Pro 2000 Operational Manual Download Page 15](http://html1.mh-extra.com/html/hamilton-manufacturing-corporation/audit-pro-2000/audit-pro-2000_operational-manual_3419688015.webp)
Document #101-0048
15
10/17/06
IV. ERROR CODES
The status of the bill changer is indicated by the green LED on the face of the Controller. When the LED is lit
constantly, it is indicating that everything is normal. An LED that remain off indicates no power or a major
failure.
When a fault is detected the green LED will begin a sequence of flashes. The sequence of flashes indicates
which error was detected. To read an error code, watch the flashing LED. Note that there is a series of flashes,
a short pause, another series of flashes, then a long pause. Wait until after the long pause, count the number of
flashes, wait while the LED pauses briefly, then count the next series of flashes. The possible errors and their
codes are listed below.
NOTE: The Audit Pro will also show the error code and a brief de-
scription of the error. you must connect the Audit Pro and press ‘ESC’
while the Controller’s LED is flashing.
Always note the error code before attempting any service or before contacting Hamilton.
To acknowledge an error code and attempt to resume normal operation, press the Controller Reset Button on
the face of the Controller.
1 FLASH, PAUSE, 1 FLASH
HOPPER 1 EMPTY
1 FLASH, PAUSE, 2 FLASHES
HOPPER 2 EMPTY
1 FLASH, PAUSE, 3 FLASHES
HOPPER 3 EMPTY
1 FLASH, PAUSE, 4 FLASHES
ALL ALTERNATING-DEFAULTING HOPPERS ARE EMPTY
2 FLASHES, PAUSE, 1 FLASH
HOPPER 1 JAMMED
2 FLASHES, PAUSE, 2 FLASHES
HOPPER 2 JAMMED
2 FLASHES, PAUSE, 3 FLASHES
HOPPER 3 JAMMED
3 FLASHES, PAUSE, 1 FLASH
NICKEL INPUT STUCK
3 FLASHES, PAUSE, 2 FLASHES
DIME INPUT STUCK
3 FLASHES, PAUSE, 3 FLASHES
QUARTER INPUT STUCK
3 FLASHES, PAUSE, 4 FLASHES
$1 INPUT STUCK
3 FLASHES, PAUSE, 5 FLASHES
$5 INPUT STUCK
4 FLASHES, PAUSE, 1 FLASH
HOPPER 1 COIN DROP STUCK
4 FLASHES, PAUSE, 2 FLASHES
HOPPER 2 COIN DROP STUCK
4 FLASHES, PAUSE, 3 FLASHES
HOPPER 3 COIN DROP STUCK
5 FLASHES, PAUSE, 1 FLASH
UNEXPECTED HOPPER 1 PAYOUT
5 FLASHES, PAUSE 2, FLASHES
UNEXPECTED HOPPER 2 PAYOUT
5 FLASHES, PAUSE, 3 FLASHES
UNEXPECTED HOPPER 3 PAYOUT
6 FLASHES, PAUSE, 1 FLASH
STACKER BUSY TIMEOUT
6 FLASHES, PAUSE, 2 FLASHES
INVALID PAYOUT SWITCH SETTING
6 FLASHES, PAUSE, 3 FLASHES
MEMORY DATA ALTERED
6 FLASHES, PAUSE, 4 FLASHES
TIMEOUT FOR VALIDATOR TO ADVANCE BILL (DUAL STACKER)
6 FLASHES, PAUSE, 5 FLASHES
VALIDATOR SHUT DOWN ERROR
7 FLASHES, PAUSE, 2 FLASHES
POWER LOSS DURING VEND
7 FLASHES, PAUSE, 3 FLASHES
INVALID TOKENOTE CODE
7 FLASHES, PAUSE, 4 FLASHES
MASTER SLAVE COM ERROR
ERROR CODES