![Hamilton Beach SmartServe MIC2000 Service Manual Download Page 60](http://html1.mh-extra.com/html/hamilton-beach/smartserve-mic2000/smartserve-mic2000_service-manual_3640883060.webp)
Page 60 of 92
520008300 08/14
SmartServe™ Drink Mixers Service Manual
Removal and Replacement
Shield Door Sensor
The shield door sensor is located under the wash chamber area. A magnet in the safety
shield assembly interacts with the sensor and requires that the door be closed in order for the
machine to operate. Some models may have two shield door sensors, one on each side of the
door assembly.
To remove the shield door sensor:
1. Remove the safety shield assembly as outlined in this manual.
2. Remove the top cover as outlined in this manual.
3. Remove three screws (1) from each side of the machine.
4. Lift the front panel wrap (2) from the machine.
NOTE:
Avoid overextending the wire harness attached to the interface panel on the wrap.
NOTE:
Cover front panel wrap to avoid scratches/damage from contact with side of machine.
5. Using a large wire tie (3), secure the wrap (2) to the machine using the hole in the top of
the side panel (4).
4
3
2
2
1
6. Remove the cup shield (5) by pressing the tab (6) in the cup guard and shield
assembly (7) and turn the cup shield (5) clockwise.
6
5
7