background image

5

Änderungen vorbehalten

          F i t t i n g  I n s t r u c t i o n

5. Interface Fitting Instruction

Safety!
The following procedures must only be carried out on condi-
tion that the mains (line) power cable is not connected to the 
oscilloscope and no connection is made at the measurement 
inputs.   
 

STOP

 Attention!

 

To avoid damage of the interface during removing 
and fi tting by electrostatic discharge, please touch 
a metal part of the oscilloscope for potential equa-
lisation between oscilloscope and your body. Abide 
this connection during the fi tting/removing! 

Only handle the interface by its IEEE-488 socket!

!

5.1 Removing of the actually inserted interface.

5.1.1

 Remove both fastening screws 

5.1.2

 Pull out the interface.

5.2 Fitting the interface HO740

5.2.1

 Insert the interface HO740 

in the opening in such a way, that 
the PCB will be inserted in the 
guidance - visible on both sides – and push it in completely.   

5.2.2

 Fit the interface with the previously (item 5.1.1) removed 

fastening screws.

Summary of Contents for IEEE-488

Page 1: ...I E E E 4 8 8 G B I P I N T E R F A C E H O 7 4 0 Fitting Instruction English...

Page 2: ...uations de tension et du flicker fluctuaciones de tensi n y flicker Datum Date Date Fecha 26 04 2007 Unterschrift Signature Signatur Signatura Holger Asmussen Manager G e n e r a l i n f o r m a t i o...

Page 3: ...aration of conformity 2 General information regarding the CE marking 2 2 Safety hints 4 3 Interface Description 4 4 Oscilloscope Firmware 4 5 Interface Fitting Instruction 5 6 Functions and settings 6...

Page 4: ...a device that receives commands from a controller delivers them to the scope and if required transmits signal data to the controller 4 Oscilloscope Firmware 4 1 It is absolutely necessary to check th...

Page 5: ...please touch a metal part of the oscilloscope for potential equa lisation between oscilloscope and your body Abide this connection during the tting removing Only handle the interface by its IEEE 488 s...

Page 6: ...following functions are not supported Switch over between local and remote with the opportunity to lock local controls RL Remote Local External start of the instruments basic functions DT Device Trigg...

Page 7: ...c e 7 Appliance The SCPI programming commands list will be provided in the Internet under www hameg com Service Support Down loads Software Firmware Software Commands for Oscillos copes HM1008 HM1508...

Page 8: ...triestra e 6 A Rohde Schwarz Company D 63533 Mainhausen registered trademark Tel 49 0 61 82 800 0 DQS Certi cation DIN EN ISO 9001 2000 Fax 49 0 61 82 800 100 Reg Nr 071040 QM sales hameg de authorize...

Reviews: