The component tester HZ65, used in conjunction with
an oscilloscope, permits time-saving tests of
semiconductors of all kinds (exception: power
electronics), resistors, capacitors and inductors. It is
exceptionally easy to operate. Evaluation of the
graphical test patterns requires a certain amount of
experience, but this is rapidly acquired if the tester is
used frequently. To support this process, a number
of typical component signatures are illustrated at the
back of these instructions.

The HZ65 has been constructed and tested in

accordance with the stipulations of

 IEC1010-1

, which

govern protective measures for electronic test
instruments, and it has left the factory with all safety
features in perfect working order. In order to maintain
it in this condition and guarantee safe, nonrisk
operation, the user should observe all notes and
warnings contained in these operating instructions.

The BNC jacks and the black banana jack are
grounded by way of the 3-conductor power
cord of the HZ65. In general, this will have no
effect on out-of-circuit testing of individual
components. When  performing  incircuit  tests,
however. Steps must be taken to ensure that
no currents are flowing within the circuit. In
the case of circuits which are themselves
grounded by way of their power connection, it
is necessary to pull the power plug of the
component tester. Double grounding can load
to incorrect test results.

Warranty

A limited warranty is granted covering proper
functioning of the HZ65 for a period of 2 years. This
warranty is void if unauthorized changes have been
made on the unit.  When mailing or shipping by rail,
we recommend packaging the unit very carefully.
Damage caused during transport by inadequate
packaging is exempted from the warranty. When
exercising this warranty, we advise attaching a note
to the housing of the unit briefly deseribing the
observed fault or faults. You will receive faster service
if you include your name and telephone number
(including area code and extension or department
designation) in case we require additional information.

Environmental conditions

Permissible ambient temperature range during
operation: + 10° to +40°C. Permissible temperature
range for storage and transport: -40°C to +70°C. If
the unit has been kept at temperatures below the dew
point (the temperature at which water vapour begins
to condense), then it must be acclimated for a certain
minimum time period before powering up.  In extre-
me cases (if the HZ65 is much colder than the dew
point), it is necessary to wait approx. 2 hours at room
temperature before beginning operation. The unit is
designed for use in clean, dry roorns.  It must not be
operated if there is a high incidence of airborne dust,
high relative humidity, risk of explosions, or if aggres-
sive chemicals are present in the environment. The
unit may be operated in any position, provided that
there is unhindered air circulation (convection cooling).

Damage to the unit

If there is reason to believe that the unit may no longer
be safely operated, then it must be powered down
and protected against accidental activation. This is
the case if:

The unit exhibits visible damage

The unit contains loose parts

The unit no longer functions

The unit has been stored under unfavorable
conditions (e.g. out of doors or in a moist area)
for a long period of time

The unit has been subjected to ahnornial stresses
during transport (e.g. as a result of not being
packaged in accordance with the minirnurn
requirements of the postal service, railway or
shipping company).

Warning
When opening or closing the enclosure, when
performing repairs or maintenance, and when
replacing parts. the unit must be isolated from
all voltage sources. If, after doing so, it is
absolutely necessary to carry out measure-
ments. troubleshooting or adjustments on the
opened unit while it is under a live voltage, then
this may only be done by a trained technician
who is familiar with the associated risks and
dangers.

Make ready and presettings

Upon delivery, the unit is set to operate on 230V ±
10% (50-60Hz). Conversion for operation on 115V ±
10% is performed in the inside of the unit by
resoldering of wired jumpers.

 Always pull the power

plug before opening the HZ65!

 After rnaking sure

that this has been done, remove the 4 screws on the
base of the unit and lift off the cover. Next to the
encapsulated input transformer is a row of  5 lands,
to wich the isolated wired jumpers shold be attached
as shown in the following diagram (series- or parallel
connection of the primary coil).

Line overcurrent protection:

Fuse: T 50mA for 230 V

isolated wire

Summary of Contents for HZ65-3

Page 1: ...GERMAN ENGLISH MANUAL HANDBUCH MANUEL ComponentTester HZ65 3...

Page 2: ...et 2 dreipoligeTransistorfassungen Polung dreifach umschaltbar Testfrequenz ca 50Hz sinusf rmig Testspannung Leerlauf ca 8 2Veff Component Tester HZ65 3 I Tests an Halbleitern I Handlich und stabil I...

Page 3: ...klung Betriebsbedingungen Zul ssiger Umgebungstemperaturbereich w hrend des Betriebs 0 C 40 C Zul ssiger Tem peraturbereich w hrend der Lagerung und des Transports 40 C 70 C Bei einerTaupunkt Un tersc...

Page 4: ...llt Offene Klemmen erzeugen dagegen eine waage rechte Linie Kondensatoren und Spulen bewirken eine Phasen differenz zwischen Strom und Spannung also auch zwischen den Ablenkspannungen Daraus ergeben s...

Page 5: ...litative Ergebnisse erh lt man beimVergleich mit funktionsf higen Bauelementen des gleichen Typs und Wertes Dies gilt insbesondere auch f r Halbleiter Man kann damit z B den kathoden seitigen Anschlu...

Page 6: ...Power cord with grounding 3 prong plug length approx 1 6 m Enclosure Made of non conductive polystyrene Dimensions 137mm x 80mm x 52 mm L x W x H Total weight approx 600g Component Tester HZ65 3 I I I...

Page 7: ...on 10 to 40 C Permissible temperature range for storage and transport 40 C to 70 C If the unit has been kept at temperatures below the dew point the temperature at which water vapour begins to condens...

Page 8: ...rcuit testing of components or testing of components with leads that will riot fit into the sockets Use the lower slide switch current to adjust the test current The recommended settings are as follow...

Page 9: ...ompared to out ofcircuit testing of individual components If you must frequently test circuits of the same type service department then here too it is useful to compare the trace pattern with that of...

Page 10: ...tra e 6 D 63533 Mainhausen Telefon 49 0 6182 800 0 Telefax 49 0 6182 800 100 E mail sales hameg de Oscilloscopes Multimeters Counters Frequency Synthesizers Generators R and LC Meters Spectrum Analyze...

Reviews: