Hameg HM 8012 User Manual Download Page 6

25

Subject to change without notice

          C o n t r o l - E l e m e n t s

on the display during initial action on the HOLD/
OFFSET key 

. Activate this function by means of 

a second press on the HOLD/OFFSET key.

  V/

   

/T°/dB/

  

(safety terminal for 4 mm banana plugs)
Connection (high potential) for measurements of 
voltages, resistances, temperatures and diode 
junctions in conjunction with the COM input 

 

(safety terminal). 

For safety reasons, the voltage across 
this terminal compared to the case (guard 
wire, ground) shall be 600 V

DC

 at most.

  HOLD/OFFSET 

(pushbutton)

Pushbutton for validating the HOLD or OFFSET 
functions. Pressing the key the fi rst time will 
freeze the front panel display. The HOLD indicator 

 then comes on. The AUTO, AC-DC, BEEP, 

 

and 

 keys are inoperative.

A second press gives access to the relative mode. 
The value memorized by the HOLD function is then 
subtracted from each measurement before being 
displayed. The OFFSET indicator 

 comes on.

A third press will freeze the relative value. The 
HOLD 

 and OFFSET 

 indicators come on. A 

fourth press will delete the HOLD and OFFSET 
mode.

    

(pushbutton)

Pushbutton for changing to lower range. On each 
press, the new range is displayed fl eetingly on the 
display in code form (L1 for lowest range, L2 for 
second range, etc.).

    

(pushbutton)

 

Pushbutton for changing to higher range. Each 
time pressed, the new range will be displayed 
fl eetingly on the display in code form (L1 for lowest 
range, L2 for second range, etc.).

  RS-232 

(DB9)

Female DB9 connector intended for serial com-
munication.

  AUTO (LED)

Indicator signalling that the multimeter is in AU-
TOMATIC mode. In this mode, action on keys 

 

and 

 is inoperative.

  AUTO 

(pushbutton) 

Pushbutton for switching the AUTO range selec-
tion to the MANUAL range selection and vice 
versa.
In MANUAL mode, the choice of range is left to 
user initiative using the keys 

 

 

and 

.

  Unit display zone 

(LED)

This zone contains a display of the measurement 
units. It also identifi es the function selected by 
pressing the 

 

  or 

   

key.

  AC-DC 

(pushbutton)

This key is used for selecting the measurement 
mode (DC, rms AC or rms AC + DC).
Indicators below indicate the measurement 
mode:

DC: 

measurement of DC voltages

AC:

 measurement of RMS AC voltages

DC + AC:

 measurement of RMS AC+DC voltages.

 

 

(pushbutton)

Pushbutton for selecting the next function.

 

 

(pushbutton)

Pushbutton for selecting the previous function. 
On startup, the unit switches automatically to 
the DC voltmeter, MANUAL mode function and 
600 voltrange.

Summary of Contents for HM 8012

Page 1: ...tion 10 V 0 01dBm 10nA 10m 0 1 C F Offset function relative value measurement in basicmeasurement functions Input impedance 1G 0 5V and 5V DC range RS 232 interface PC software for control and data lo...

Page 2: ...curacy 23 8 59 8dBm 0 2dBm Resolution 0 01dB above 9mV CMRR3 60dB 50 60Hz 0 5 Crest factor 7 max AC current Measurement ranges 500 A 5mA 50mA 500mA 10A Resolution 10nA 100nA 1 A 10 A 1mA Accuracy 0 5...

Page 3: ...r discon nection of the protective earth terminal is likely to render the instrument dangerous Intentional interruption is prohibited The istrument must be disconnected and secured against unintention...

Page 4: ...ould be taken to ensure that it properly ts under the edges of the front and rear frames After removal of the two screws at the rear of the module both chassis covers can be lifted When reclosing the...

Page 5: ...in con junction with the COM input low potential Current in excess of 10 A max 20 A must not be applied for a period exceeding 30 s otherwise the internal measurement resistor thermal device will blo...

Page 6: ...er range On each press the new range is displayed eetingly on the display in code form L1 for lowest range L2 for second range etc pushbutton Pushbutton for changing to higher range Each time pressed...

Page 7: ...ower range is obtained when the value drops below 4 900 counts It is possible to know which range has been selected by the unit by temporarily deactivating the AUTO mode so that the range indication c...

Page 8: ...8012 should be connected to the circuit whosepotentialwithrespecttogroundislowest For safety reasons the COM terminal must not exceed 250VDC with respect to ground Currentrangesareprotectedbyfuseagain...

Page 9: ...erpreting measurement values and for evaluating its accuracy It is de ned as the ratio between the peak voltage and the rms value of the signal Crest factor CF Vp VRMS It is a measurement of the dynam...

Page 10: ...temperature of 0 C and using the OFFSET function Note Measurement of the temperature probe line resistance should be made on the same in strument used for temperature measurements Only this procedure...

Page 11: ...eys on the front panel AY CR switches to automatic range change AN CR switches to manual range change R CR switches to the next higher range R CR switches to the next lower range If it is impossible t...

Page 12: ...mA Diode 3 50 V 50 k 50 mA 4 500 V 500 k 500 mA 5 1000 V 5 M 6 50 M 10 A P CR This command alone is used for reco vering complete parameter settings of the equipment The instrument returns string_F s...

Page 13: ...500 k 5M 0 02 for instance models CNS020 by Vishay Test procedure If one of the indicated calibrators is available or if precision calibrators are appropriate all the HM8012 measurements ranges can be...

Page 14: ...guration This one can be saved and recalled later When the con guration of the instrument is done a set of measurements can be carried out and saved for future use Furthermore the software can show d...

Reviews: