Alarm Indications
1:
• •
•
– Ascent side current detected. This can be caused by an overload, upper limit switch defect,
excess current through the motor when the table was rising, or other reasons.
2:
•
•
•
– Descent side current detected. This can be caused by an overload, lower limit switch defect,
3:
•
• •
– Ascent defect (did not go up for some reason)
4:
•
• •
– Descent defect (did not go down for some reason)
5:
•
•
•
– Limit switch abnormality (the upper and lower limit switches come ON at the same time due to
6:
• • •
– Sensor abnormality (hall sensor abnormality).
7:
•
• •
➞
•
•
•
➞
• •
•
Repeat – foot switch abnormalities (when the power is first turned on,
a foot switch is ON).
How to Reset the Alarm
Alarms 1–4: Press down the opposite side foot switch.
Alarms 5 and 6: Turn off the power.
Other Functions
Please consult manufacturer before performing any modifications or alterations.
(Use the connection wiring diagram on the following page for reference.)
Please consult manufacturer before performing any modifications or alterations.
Hold Mode
(3-point push-button type)
Add the stop input
(Use the connection wiring diagram on the following page for reference.)
Sequencer Input
Always input with dry contacts.
(Input from not a voltage contact but non-voltage contacts, such as a transistor point of contact. )
WARNING
DO NOT OPERATE UNTIL THE LED LIGHT ON THE BOARD TURNS COMPLETELY OFF
AFTER POWERING DOWN.
CAUTION
Check that the upper and lower limit switches are working properly. Malfunction can damage the machine.
•