Instruction Manual PSx3xxPL
12
2.5.5 Electrical grounding (Chassis)
Next to the connecting plugs there is a M4 stud bolt. It is recommended to connect
the positioning system with a cable as short as possible to the machine base. The
minimum wire cross section therefor is 1.5mm².
2.6
Setting the device address
Removing the protective cap provides access to two rotary switches for setting the
device address at the bus.
The rotary switches indicate the tens and ones places of the address selected.
The delivery setting is 00, i.e. before the first start-up a valid address has to be set.
2.7
LEDs
The following LEDs are located under the transparent sealing plug:
P1/P2
: green Link/Act LEDs for ports 1 and 2
BS/BE
: Powerlink STATUS and ERROR LEDs (green/red; see Powerlink spec.)
V_Motor
: The LED is illuminated yellow when power is available to the motor.
Switch configurations:
PSx30x, PSx31x-8,
PSx31x-14, PSx33x
PSx32x, PSE31xx,
PSE34xx
Meaning of the LEDs:
1)
Each of the ports (P1/P2) has an associated green LED for the “Link” and the
“Activity” state.
For each port the following states are possible:
- Off
no connection
- On
connection; data transmission inactive
- Flickering with 10 Hz
connection; data transmission active
2) Green and red Powerlink LEDs
Powerlink STATUS and ERROR LEDs (green/red; see 2.9 Powerlink interface)
3
) The yellow LED “Motor” indicates the supply voltage for the motor:
- Off
supply voltage for motor too low or too high
- On
supply voltage for motor ok