Instruction Manual PSx3xxPL
14
2.8.2 Manual run
- Start manual run (transmit PDO with control word = 0x11 resp. 0x12 or, if pre-
operational, transmit SDO #2024 with value 0x11 resp. 0x12): device begins to run
- End manual run by clearing the manual run command (transmit PDO with control
word = 0x10 or, if pre-operational, transmit SDO #2024 with value 0x10) or by
deasserting release (transmit PDO with control word = 0x00 or, if pre-operational,
transmit SDO #2024 with value 0x00).
- Transferring a target value during a manual run will end the manual run and the
device will immediately move on to the transmitted position (PDO with control word =
0x14 and desired target value). If pre-operational, target value to SDO #2001. The
drive then automatically deasserts the manual run bits in the control word (bits 0 and
1).
2.8.3 Restoring the factory settings (without control system)
It is possible to reset the device to the delivery state even without the presence of a
control system. To do this, carry out the following steps:
1) Switch off the device.
2) Set the address switch to 98.
3) Switch on the device (control and motor supply voltage).
4) The yellow LED now flashes at 10Hz for 10 seconds. If during this time the address
is set to 99, the drive will set all parameters to the factory settings, save them and
move the axle to the centre position.
5) Set the address switch to 00 to complete the delivery state.
6) Switch off the device.
The 10-second period is ended prematurely when a communication is established.
2.9
Powerlink interface
The Powerlink interface is realized according the EPSG standard 301, version 1.2.0:
One send and receive SDO per device
One asynchron send and receive PDO, active by default
Meaning of the LEDs:
1) Each of the ports (P1/P2) has an associated green LED for the “Link” and
the “Activity” state.
For each port the following states are possible:
- Off
no connection
- On
connection; data transmission inactive
- Flickering with 10 Hz
connection; data transmission active
2) The green Powerlink LED “Bus Status” (BS) signalizes the CN cycle state.
- Off
NOT_ACTIVE
- Flickering with 10 Hz
BASIC_ETHERNET
- Single flashing with 0.8 Hz
PRE-OPERATIONAL_1
- Double flashing with 0.6 Hz
PRE-OPERATIONAL_2
- Triple flashing with 0.5 Hz
READY_TO_OPERATE
- Flashing with 2.5Hz
STOPPED
- On
OPERATIONAL