background image

 

 
 
 

Instruction Manual 
PU/PI and PS10  
Differential Pressure 
Transducers

 

 
 

 
halstrup-walcher GmbH 
 
Stegener Straße 10 
D-79199 Kirchzarten 
Germany 
 
Phone:  +49 (0) 76 61/39 63

–0 

Fax: 

+49 (0) 76 61/39 63

–99 

 
E-Mail:  [email protected] 
Internet: www.halstrup-walcher.com 

 
 
Document 7100.001784 Version 5.3  02/2010 

Summary of Contents for PI10

Page 1: ...Pressure Transducers halstrup walcher GmbH Stegener Stra e 10 D 79199 Kirchzarten Germany Phone 49 0 76 61 39 63 0 Fax 49 0 76 61 39 63 99 E Mail info halstrup walcher com Internet www halstrup walche...

Page 2: ...ctions and start up 4 1 3 Troubleshooting maintenance repairs disposal 4 1 4 Symbols 5 2 Instrument description 6 3 Start up 6 3 1 Features 6 3 2 Supply voltage connections in the instrument 7 3 3 Ana...

Page 3: ...e throughout the lifecycle of the instrument It must be provided to any individuals who assume responsibility for operating the instrument at a later date It must include any supplementary materials p...

Page 4: ...ely trained and authorized by the operator of the facility may assemble the instrument and set up its electrical connections The instrument may only be operated by appropriately trained individuals wh...

Page 5: ...The symbols given below are used throughout this manual to indicate instances when improper operation could result in the following hazards WARNING This warns you of a potential hazard that could lead...

Page 6: ...theless precision instruments and should be handled with care Avoid mounting the instruments in the direct vicinity of any sources of radiation or heat such as heaters as this could result in measurem...

Page 7: ...connection diagram located on the housing cover circuit board mount 3 3 Analog output connections in the instrument The transducer outputs are protected from short circuits Instruments supplied with d...

Page 8: ...ark when calibrating the zero point Were this not the case the negative component which cannot be displayed would interfere with the output signal After the pressure transducer has warmed up the opera...

Page 9: ...de pressure ports reversed Send the instrument to the manufacturer for repair connect pressure as outlined in section 3 Mounting output signal incorrect only for 0 20 mA defective output protection di...

Page 10: ...s 250 Pa optional 2 for PS 10 model others available upon request temperature dependent drift in zero point 0 04 K in the 10 C 50 C range for PU PI model 0 1 K in the 10 C 50 C range for PS 10 model t...

Page 11: ...6 5 mm for NW5 tubing interior tubing diameter 5 mm electrical connections screw terminals for cables up to 2 5 mm2 mounting orientation vertical when placing your order please indicate if a horizont...

Page 12: ...PU PI and PS10 Instruction Manual 12 7 Dimension drawings PU PI PS10 standard 120 135 151 20 80 25 33 7 4 5 34 73 PU PI PS10 with LCD 122 17 25 22 75 Option LCD 4 5 111 90 5 20 120...