Safety precautions 

3.1 

Appropriate use 

The EMA 200 is a portable, battery-powered digital pressure gauge for measuring 
positive and negative differential pressures. At the heart of this precision instrument is 
a pressure measurement capsule containing a membrane spring; the deflection of 
this spring is then ascertained via an inductive measurement principle. Because it is 
durable and easy-to-use, the EMA 200 lends itself well to maintenance work and 
customer servicing for heating, air-conditioning and ventilation units, where it can be 
used for monitoring filters, measuring fireplace drafts and wind pressure, etc.Its 
precision and reproducibility also make the EMA 200 is highly suitable for use in 
laboratory applications. 
 
Always observe the operating requirements

—particularly the permissible supply 

voltage

—indicated on the rating plate and in the “Technical data” section of this 

manual. 
 
The instrument may only be handled as indicated in this manual. Modifications to the 
instrument are prohibited. The manufacturer is not liable for damages caused by 
improper use or failure to follow these instructions. Violations of this type render all 
warranty claims null and void. 
 
 

3.2 

Troubleshooting, maintenance, repairs, disposal

 

The individual responsible for the electrical connections must be notified immediately 
if the instrument is damaged or if errors occur. 
 
This individual must take the instrument out of service until the error has been 
corrected and ensure that it cannot be used unintentionally. 

 

This instrument requires no maintenance. 

 

Only the manufacturer may perform repairs that require the housing to be opened. 
 
The electronic components of the instrument contain materials that can be reused. 
For this reason the instrument must be recycled in accordance with the environmental 
guidelines of the jurisdiction in question once it has been taken permanently out of 
service.  

Summary of Contents for EMA 200

Page 1: ...ssure Gauge halstrup walcher GmbH Stegener Stra e 10 D 79199 Kirchzarten Germany Phone 49 0 76 61 39 63 0 Fax 49 0 76 61 39 63 99 E Mail info halstrup walcher com Internet www halstrup walcher com Doc...

Page 2: ...ng the instrument on off 7 6 2 Display modes measurement hold max min 7 6 3 Changing pressure units 8 6 4 Zeroing key 8 6 5 Analogue output 9 7 Configuration 9 7 1 Setting units of pressure 9 7 2 Temp...

Page 3: ...out the lifecycle of the instrument It must be provided to any individuals who assume responsibility for operating the instrument at a later date It must include any supplementary materials provided b...

Page 4: ...the rating plate and in the Technical data section of this manual The instrument may only be handled as indicated in this manual Modifications to the instrument are prohibited The manufacturer is not...

Page 5: ...warns you of a potential hazard that could lead to bodily injury up to and including death if the corresponding instructions are not followed WARNING This warns you of a potential hazard that could le...

Page 6: ...ng units At its heart is a pressure measurement capsule with a beryllium bronze membrane spring which is displaced by the pressure difference between the two chambers of the measurement capsule Measur...

Page 7: ...onnect the and ports appropriately for measuring differential pressure 6 Operating the instrument The following sections explain how to operate the instrument correctly 6 1 Switching the instrument on...

Page 8: ...l use the new units until it is switched on off or until the next time the units are changed The units selected during configuration see section 7 are always set when the instrument is switched on 6 4...

Page 9: ...point key until ConF appears in the top line of the display After the operator releases this key the instrument launches the first item setting units of pressure To exit the configuration menu simply...

Page 10: ...pressing the and keys Briefly depressing the key will exit this mode If the flow rate display has been activated the menu for setting the density of the medium to be measured appears if not the next...

Page 11: ...ween 20 and 100 of the measurement range While operators may enter final pressures 20 doing so will decrease the DA resolution The bottom line of the display will show the code AnH Selects which digit...

Page 12: ...s an auto on off function that can be used to avoid consuming battery power unnecessarily This feature which can be toggled on and off will power down the instrument after 20 minutes if the pressure d...

Page 13: ...s parameter is used to reset the instrument to its default settings if desired The bottom line of the display will show the code rES Turns this function on yes or off no Turns this function on yes or...

Page 14: ...nstall new battery use a 9V IEC 6 LR 61 battery instrument returns false values zero point has shifted battery is low adjust zero point see section 4 4 Batt appears in the display field i e replace ba...

Page 15: ...in the meas range 3 place LCD for flow rate temp measurement resolution 1 C accuracy 1 C measurement range 0 60 C analogue output max output voltage 3 3V permissible load 2k temperature range storage...

Page 16: ...pressure changes by more than 2 of the final value or the operator presses a button Each time this happens the wait period is reset to 20 minutes Appendix A Parts in contact with measurement medium B...

Page 17: ...EMA 200 Instruction Manual 17 10 Drawings analogue output 3 5 mm jack...

Reviews: