background image

  HVRGRN8BLWS*1C     HVRGRN8BLWSNF*1C

1000001740  (Rev. P - 03/23) 

Page 3

12

 5

/16

"

31

3m

m

1/2

"

89

mm

18

 3

/4"

47

6m

m

1/4

"

15

9m

m

20

 1/

8"

51

1m

m

20

 3

/8"

51

8m

m

7/1

6"

63

m

m

5"

12

7m

m

10

"

25

4m

m

A

D

E

F

B

FIN

ISH

ED

 FL

OO

R

HA

NG

ER

 BR

AC

KE

T

13

 7/

8"

35

2m

m

37

 1/

2"

95

2m

m

1 3

/8"

35

m

m

1 3

/8"

35

m

m

3/4

"

14

6m

m

3/4

"

14

6m

m

1 3

/8"

35

mm

1 3

/8"

35

mm

3/4

"

14

6m

m

3/4

"

14

6m

m

1/2

"

16

5m

m

18

 1/

16

"

45

9m

m

11/

16

"

18

m

m

9/1

6"

116

mm

9/1

6"

65

mm

7 1

/4"

18

5m

m

E

F

5/

16

" (8

m

m)

 DI

A.

(10

 HO

LE

S)

LC

LC

27

"

68

6m

m

AD

RE

QU

RIE

ME

NT

S*

C

1/8

"

10

5m

m

3/4

"

17

2m

m

8"

20

3m

m

7"

17

8m

m

7"

17

8m

m

17

 7/

8"

45

4m

m

58

 9/

16

"

14

88

mm

15

"

38

1m

m

9/1

6"

90

mm

18

 7/

8"

47

9m

m

31

 15

/16

"

81

1m

m

RIM

 HE

IGH

T

18

 5

/8"

47

2m

m

33

"

83

8m

m

OR

IFI

CE

 HE

IGH

T

39

 7/

16

"

10

02

mm

OR

IFI

CE

 HE

IGH

T

5/8

"

67

m

m

AC

TIV

AT

ION

  S

EN

SO

R

45

 9/

16

"

115

7m

m

25

 1/

8"

63

8m

m

1/2

"

114

m

m

Fig. 2

REDUCE HEIGHT BY

 3" FOR INST

ALLA

TION OF CHILDREN'S 

ADA

 COOLER

STANDARD TWO-LEVEL INSTALLATION

LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED W

ATER SUPPL

Y LOCA

TION 3/8 O.D. UNPLA

TED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY

 OTHERS) 3 IN. (76

mm

MAXIMUM OUT FROM W

ALL

 

  La UBICACION 3/8 O RECOMENDADA

 de 

ABASTECIMIENT

O DE 

AGUA. D. El 

TUBO del COBRE de UNPLA

TED CONECT

TALONARIO CON 

AP

AGO 

(POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA

 DE P

ARED

        

L’O.D de 3/8 d’EMPLACEMENT

 DE PROVISION D’EAU RECOMMANDE. LE 

TUBE DE CUIVRE DE UNPLA

TED CONNECTE STUB 

AVEC ETEINT

 (P

AR 

LES 

AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU MUR

B = RECOMMENDED LOCA

TION FOR W

ASTE OUTLET 1-1/2” O.D.  DRAIN STUB 2 IN. OUT FROM W

ALL

 UBICACIÓN RECOMENDADA

 P

ARA

 EL

 DRENAJE DE SALIDA

 DE 

AGUA, DE 1-1/2” DE DIÁMETRO. 

El 

TALONARIO 2 FUERA

 DE P

ARED

EMPLACEMENT

 RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2” DE SOR

TIE D’EAU. 

STUB 2 HORS DU MUR

C = 1-1/2” TRAP

 NOT FURNISHED

PURGADOR DE 1-1/2” NO PROPORCIONADO SIPHON 1-1/2” NON FOURNI

LEGEND/LEYENDA/LÉGENDE D = ELECTRICAL

 SUPPL

Y (3) WIRE RECESSED BOX DUPLEX OUTLET**

SUMINISTRO ELÉCTRICO (3) CAJA

 ENCHUFE DE 

ALAMBRE SALIDA

 DÚPLEX

ALIMENT

ATION ÉLECTRIQUE (3) BOÎTIER ENCASTRÉ

E = INSURE PROPER VENTILA

TION BY

 MAINT

AINING 6” (152 

mm

) (MIN.) CLEARANCE FROM CABINET LOUVERS T

O W

ALL.

ASEGURE UNA

 VENTILACIÓN 

ADECUADA

 MANTENIENDO UN ESP

ACIO E 6” (152 

mm

) (MÍN.) DE HOLGURA

 ENTRE LA

 REJILLA

DE VENTILACIÓN DEL

 MUEBLE 

Y LA

 P

ARED.

ASSUREZ-VOUS UNE BONNE VENTILA

TION EN GARDANT

 6” (152 

mm

) (MIN.) ENTRE LES ÉVENTS DE L

’ENCEINTE ET

 LE MUR.

F = 7/16 BOL

T HOLES FOR F

ASTENING UNIT T

O W

ALL

AGUJEROS DE LAS 

TUERCAS DE 7/16 P

ARA

 SUJET

AR LA

 UNIDAD 

A LA

 P

ARED

TROUS D’ÉCROUS 7/16 POUR FIXER L

’APP

AREIL

 AU MUR

**NEW INST

ALLA

TIONS MUST USE GROUND F

AUL

T CIRCUIT INTERRUPTER (GFCI)

**

Las nuevas instalaciones deben utilizar el interruptor de circuito de tierra de la avería (GFCI)

**

Les nouvelles installations doivent employer l’interrupteur de circuit moulu de défaut (GFCI)

Summary of Contents for Hydroboost HVRGRN8BLWS 1C Series

Page 1: ...Cooler Owners Manual Estaci n de llenado de botella Hydroboost y enfriador Station de remplissage de bouteille Hydroboost et refroidisseur WARNING Cancer and Reproductive Harm www P65Warnings ca gov...

Page 2: ...5 19 12 Pictured is unit only without bottle filler Uses HFC 134A refrigerant Usa refrigerante HFC 134A Utilise du fluide frigorig ne HFC 134A Note Danger Electric shock hazard Disconnect power befor...

Page 3: ...A DE PARED L O D de 3 8 d EMPLACEMENT DE PROVISION D EAU RECOMMANDE LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT PAR LES AUTRES 3 dans 76 mm le MAXIMUM HORS DU MUR B RECOMMENDED LOCATION FO...

Page 4: ...e posterior del enfriador como se indica en la figura 4 5 Afloje los dos 2 tornillos que sostienen la parte inferior del panel en la parte inferior de la base del enfriador y los dos 2 tornillos en la...

Page 5: ...S 1C HVRGRN8BLWSNF 1C 1000001740 Rev P 03 23 Page 5 Fig 5 27 2 2 2 26 2 2 1 PUSH BUTTON MECHANISM MECANISMO DE BARRA DE EMPUJE M CANISME DU BOUTON POUSSOIR 2 28 9 17 Fig 6 Fig 7 16 4B 24 20 24 25 4A 2...

Page 6: ...om the wall mounting plate installed on wall Make sure round boss in gasket fits in hole of basin See Fig 12 9 Once Bottle Filler is installed on wall plate tabs water line and power cord are installe...

Page 7: ...ay will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the but...

Page 8: ...3000 Gallon Kit filtre raccord de t te comprend Raccords John Guest Assembl e filtre t te Support inclut John Guest vis DESCRIPTION FILTER PARTS LIST See Fig 15 LISTA DE PIEZAS DEL FIL TRO Vea la Fig...

Page 9: ...83C 5 16 1 4 Pack de 3 Kit Tee 1 4 x 1 4 x 3 8 Pack de 3 Kit 10 Torx vis T 25 bits Kit de Filtrage d Eau Si Fourni DESCRIPTION Panel Bottom Dispenser Kit Push Button Assy Button Sleeve Nuts Spacer Han...

Reviews: