Page 6
98986C (Rev. M - 12/17)
HTHBHVR8-NF*1A, *2A, *3A HTHBHVR-NF*A, *2A HTHBHVR8*1A, *2A, *3A HTHBHVR*A, *2A
REMOVAL OF BOTTLE FILLER FOR SERVICING
1)
Turn off the water supply to the Water Cooler.
Unplug and/or turn off Circuit Breaker to Cooler and Bottle Filler.
NOTE:
the Lower Front Panel of the cooler(s) may need to be removed. To prevent scratching the basin place a towel or soft cloth over the entire basin when working
above it.
2)
Loosen but DO NOT remove the two (2) Pinned Torx Head Screws
from the sides of the Bottle Filler. Remove the two (2) Pinned Torx Head Screws from the
Top Cover & remove the Top Cover. The Bottle Filler may then be lifted up and off the Water Cooler (The waterline and Remote Reset Button Wires will still be
connected from the Water Cooler to the Bottle Filler.)
Fig. 6
TOP COVER SCREWS
BOTTLE FILLER
SIDE SCREWS
BOTTLE FILLER
SIDE SCREWS