Page 6
HAC8FSCWSNFQ_2F
1000002478 (Rev. D - 09/18)
2. Bubbler
: Mineral deposits on the orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with
a small round file not over 1/8” (3 mm) diameter or small diameter wire.
• CAUTION: DO NOT file or cut orifice material. Care must be taken not to damage the orifice(s)
3.
Condenser Fan Motor: Confirm condenser fan turns freely. If the condenser fan does not spin freely, have an authorized service personnel
replace.
4. Ventilation
: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose or vacuum cleaner. Cleaning should be
done twice each year or more frequently if needed due to environment. Excess dirt or poor ventilation can cause no cold water and
compressor cycling on the compressor overload protector.
5.
Water Flow: Confirm proper water flow. If water flow is slow, inspect filter or inline strainer for restriction. Replace filter cartridge if required.
Disassemble inline strainer and clean if required.
6.
Lubrication
: Motors are lifetime lubricated.
7.
Actuation of Quick Connect Water Fittings:
Cooler is provided with lead-free connectors
which utilize o-ring water seal. To remove tubing from the fitting, relieve water pressure,
push in on the gray collar before pulling on the tubing. To insert tubing, push tube straight
into fitting until it reaches a positive stop, approximately 3/4” (19mm).
Service: Inspection/Replacement
•
Inspect Bottle Filler and Cooler twice each year for proper operation and performance.
•
Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.
1. Lower Front Panel and Upper Shroud
: To access the refrigeration system and plumbing connections, loosen two (2) screws holding the lower front
panel at the bottom of the cooler base and two (2) screws at the top using a T-20 Torx Bit.
2. Cleaning the Strainer:
To clean the Strainer (Item 15), first shut off water supply and remove strainer from waterline. Remove plug and screen.
Clean screen and rinse thoroughly with water. Insert screen back into strainer and reassemble. Lubricate O-Ring with food grade pharmaceutical
mineral oil. Do not overtighten plug or fittings. See Figure 10.
B
C
A
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C
CORRECT STREAM HEIGHT
Figure 9
Figure 11
8
7
8
9
8
8
14
8
7
C
9
29
27
8
8
9
2
1
A
26 B
PUSH BAR MECHANISM
28
7
7
9
11
10
Figure 12
LEGEND
A =
Note: Water flow direction
B = Adjust this screw to eliminate
mechanism “Free Play” or
continuous flow from bubbler
c o n d i t i o n s . ( S e e s e r v i c e
adjustments, item 4)
C = Stream height adjustment
A
C
B
D
A = Plug with 7/8" (22.2mm) Hex
B = O-ring
C = Screen
D = Strainer Body with 1" (25.4mm) Hex
Figure 10
Service: Inspection/Cleaning
•
Inspect Bottle Filler and Cooler twice each year for proper operation and performance.
•
Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.
1. Cleaning
: Warm, soapy water or mild household cleaning products can be used to clean the exterior panels. Extra caution should be used to
clean the mirror finished stainless steel panels. They can be easily scratched and should only be cleaned with mild soap and water or Windex
glass cleaner and a clean, soft cloth. Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty.
2. Bubbler
: Mineral deposits on the orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a
small round file not over 1/8” (3 mm) diameter or small diameter wire.
•
CAUTION: DO NOT file or cut orifice material. Care must be taken not to damage the orifice(s)
3.
Condenser Fan Motor: Confirm condenser fan turns freely. If the condenser fan does not spin freely, have an authorized service personnel replace.
4. Ventilation
: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose or vacuum cleaner. Cleaning should be
done twice each year or more frequently if needed due to environment. Excess dirt or poor ventilation can cause no cold water and compressor
cycling on the compressor overload protector.
5.
Water Flow: Confirm proper water flow. If water flow is slow, inspect filter or inline strainer for restriction. Replace filter cartridge if required.
Disassemble inline strainer and clean if required.
6.
Lubrication
: Motors are lifetime lubricated.