background image

97803C (Rev. D - 5/04)

HCRFEBP*A

PAGE 4

PART NO.

ITEM NO.

PARTS LIST

Strainer

Retaining Nut

Push Button

Push Button Sleeve

Regulator Holder

Bubbler Assy

Gasket

Bubbler - Nipple

Regulator

Set Screw  #6-32 X .31"

Screw - #10-24 X .50 PHTC

Strainer

Fountain Arm - Long

Bottom Cover Plate - Long

Back Panel

Hex Nut

Regulator Mounting Bracket

Poly Tubing (Cut To Length)

Mounting Plate Assy

Drain - Tailpipe

Drain - Adapter

Gasket - Tail Pipe

Tube - Water In

Nut-Regulator Mounting

Washer - Flat .339/.359ID Steel

Screw - Mach. 5/16-18 x 3/4

Set Screw  #6-32 X .12"

Wrench-Allen

40575C

15005C

45662C

45737C

50986C

51544C

100322740560

15008C

61313C

70022C

112627543890

55996C

55001130

55000665

28290C

40045C

28291C

56092C

28286C

45679C

45805C

50074C

62095C

45736C

75541C

111577243890

70023C

75539C

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

NS

DESCRIPTION

FIG. 7

FIG. 6

16

2

9

5

3

4

17

27

13

SEE FIG. 6

15

SEE

FIG. 5

14

1,20,21,22

12

FIG. 5

18

19

23

6

7

8

FIG. 4

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

2222 CAMDEN COURT

OAK BROOK, IL 60523

630.574.3500

PRINTED IN U.S.A.

24

11

25,26

10

Summary of Contents for HCRF-EBP

Page 1: ...G OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATINGAN ELECTROLYSIS WHICH CAUSESA METALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING...

Page 2: ... 2 LEGEND A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUBBED 1 1 2 38mm FROM WALL SHUT OFF BY OTHERS B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN C 1 1 4 DRAIN FURNISHED HCRF EBP ROUGH IN FIG 3 ...

Page 3: ...ne should be insulated after leak check is completed DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O RINGS MAY RESULT 8 These products are designed to operate on 20 105 PSIG supply line pressure If inlet pressure is above 105 PSIG a pressure regulator must be installed in the supply line Any damage caused by reason of connecting these products to supply line pressure lower than 2...

Page 4: ...ting Washer Flat 339 359ID Steel Screw Mach 5 16 18 x 3 4 Set Screw 6 32 X 12 Wrench Allen 40575C 15005C 45662C 45737C 50986C 51544C 100322740560 15008C 61313C 70022C 112627543890 55996C 55001130 55000665 28290C 40045C 28291C 56092C 28286C 45679C 45805C 50074C 62095C 45736C 75541C 111577243890 70023C 75539C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 NS DESCRIPTION FIG ...

Reviews: