background image

97883C (Rev. A - 4/04)

BFMRQ*A

PAGE 6

FIG. 10

FIG. 11

TO BUBBLER

26

27

25

26

3

1

SEE FIG. 6

SEE FIG. 12

14

SEE FIG. 13

5

4

6

7

2

18

CHILLER

OUTLET

CHILLER INLET

Summary of Contents for BFMRQ*A Series

Page 1: ...THE GROUNDING OF ELECTRICAL EQUIPMENT SUCHAS TELEPHONE COMPUTERS ETC TOWATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSESA METALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALSAS I...

Page 2: ...for location of supply water inlet to chiller and for location of waste water outlet 4 Install shelf support rods on wall frame assembly These rods are located in the chiller shelf package To install chiller shelf place shelf on chiller support bracket and attach to support rods Secure front edge of the shelf to support bracket using two 2 provided 5 16 x 3 4 long bolts and nuts Tighten securely 5...

Page 3: ... to meet local codes see Step No 1 of installation instructions height dimensions must be adjusted accordingly LEGEND A 1 4 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT CHILLER WATER INLET SHUT OFF VALVE BY OTHERS C 1 1 4 O D WASTE WATER OUTLET TUBE TRAP NOT FURNISHED D ELECTRICAL INLET ...

Page 4: ... 64 ID washers See Figs 8 9 6 Install waste tube assembly Align threaded portion of drain tube assembly with drain hole in basin Place rubber gasket between drain assembly and basin Screw in drain plug from above and tighten securely Snap strainer plate into drain plug See Fig 13 7 Make connection between remote chiller outlet tube and fountain Outlet port is marked on the chiller 1 4 O D copper t...

Page 5: ...97883C Rev A 4 04 BFMRQ A PAGE 5 FIG 7 FIG 8 FIG 9 18 31 30 32 28 29 ...

Page 6: ...97883C Rev A 4 04 BFMRQ A PAGE 6 FIG 10 FIG 11 TO BUBBLER 26 27 25 26 3 1 SEE FIG 6 SEE FIG 12 14 SEE FIG 13 5 4 6 7 2 18 CHILLER OUTLET CHILLERINLET ...

Page 7: ... In Line Strainer Union 1 4 Poly Tubing Cut To Length Washer Flat Washer Flat 10 SS Wing Nut 10 24 Screw 8 x 75 Basin Bracket Screw 10 24 x 62 HHMS 23 24 21 FRONT PANEL 20 22 19 TROUBLE SHOOTING AND MAINTENANCE Orifice Assy Mineral deposits on orifice can cause water flow to spurt or not regulate Mineral deposits may be removed from the orifice with a small round file not over 1 8 diameter or smal...

Page 8: ...97883C Rev A 4 04 BFMRQ A PAGE 8 THIS PAGE INTENTIONALLY LEFT BLANK ...

Reviews: