![Halma 10BODYGUARDIII User Manual Download Page 8](http://html1.mh-extra.com/html/halma/10bodyguardiii/10bodyguardiii_user-manual_580889008.webp)
PROGRAMMING
GUIDE – PATTERN
ADJUSTMENTS
75.5184.09 EN 20110819
Page 8 of 13
THRESHOLD
: The Threshold is always OFF when the door is closed.
PATTERN WIDTH OR DEPTH
: When pattern width or depth is changed, a setup of the new pattern
size will automatically be triggered once a value key has been pressed.
Pattern Width
Door Open or
Closed
1: Wide (closed door)
2 : Middle (open door)
3 : Asymmetric Left Narrow
4 : Asymmetric Right Narrow
5 : Narrow Left
6 : Narrow Right
7 : Asymmetric Left Wide
8 : Asymmetric Right Wide
9 : Center Narrow
See PATTERN WIDTH or DEPTH
Pattern Depth
1: Deep – Threshold ON
2 : Medium – Threshold ON (open)
3 : Limited – Threshold ON
4 : Deep – Threshold OFF
5 : Medium – Threshold OFF (closed)
6 : Limited – Threshold OFF
See THRESHOLD
See PATTERN WIDTH or DEPTH
Sensitivity
Door Open-Closed
0
(min)
→
9
(max)
(default 7 for
door open, default 6 for door
closed)
Immunity
1: Low
(Normal)
2 : Medium - Rain (Disregards more
floor disturbances)
3 : High - Snow (Disregards
greatest floor disturbances)
Automatic Learn
Time
0: 30 seconds
1: 1 minute
2: 2 minutes
3: 3 minutes
4: 5 minutes
5: 7 minutes
6: 10 minutes
7: 15 minutes
8: 10 seconds
9: Infinity – no learn
Modes of Operation
0: Normal
1: MP mode
2: Record mode
OBSOLETE