Halma 10BODYGUARDIII User Manual Download Page 8

 

PROGRAMMING 
GUIDE – PATTERN 
ADJUSTMENTS 

 

 
 

75.5184.09  EN   20110819 

 

Page 8 of 13 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

THRESHOLD

:  The Threshold is always OFF when the door is closed. 

 

PATTERN WIDTH OR DEPTH

:  When pattern width or depth is changed, a setup of the new pattern 

size will automatically be triggered once a value key has been pressed. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Pattern Width 
Door Open or 

Closed

 

 

 
1: Wide (closed door) 
2 : Middle (open door) 

3 : Asymmetric Left Narrow 
4 : Asymmetric Right Narrow 
5 : Narrow Left 
6 : Narrow Right 
7 : Asymmetric Left Wide 
8 : Asymmetric Right Wide 
9 : Center Narrow 
 

See PATTERN WIDTH or DEPTH 

 

Pattern Depth 

     

 

 

 

1:  Deep – Threshold ON 

2 : Medium – Threshold ON (open) 

3 : Limited – Threshold ON 
4 : Deep – Threshold OFF 

5 : Medium – Threshold OFF (closed) 

6 : Limited – Threshold OFF 
 

See THRESHOLD 
See PATTERN WIDTH or DEPTH

  

 

Sensitivity  

Door Open-Closed

 

 

 

 

0

 (min) 

 

9

 (max) 

(default 7 for 

door  open, default 6 for door 
closed)

 

 

 

Immunity 

 

 

1: Low 

(Normal) 

2 :  Medium - Rain (Disregards more 

floor disturbances) 

3 :  High - Snow (Disregards 

greatest floor disturbances) 

 

 

Automatic Learn 

Time

 

 
0: 30 seconds 

1: 1 minute 
2: 2  minutes  
3: 3 minutes 
4: 5 minutes 
5: 7 minutes 
6: 10 minutes 
7: 15 minutes 
8: 10 seconds 
9: Infinity – no learn 

 

Modes of Operation 

 

 

0: Normal

 

1: MP mode 
2: Record mode 

OBSOLETE

Summary of Contents for 10BODYGUARDIII

Page 1: ...iry of existing settings Should the need arise the Bodyguard may also be tuned by means of two sensor mounted buttons contained on the PC Board within the unit With these two buttons the Bodyguard s f...

Page 2: ...ould be mounted above the door on the swing side The Bodyguard shall be mounted flush with the bottom of the automatic door header This is absolutely necessary to allow the detection pattern to reach...

Page 3: ...nal block OR use the cable that is provided for use with the 10 pin connector Picture 10 If wiring the Bodyguard to a BEA module such as an LO 21 or an MC 15 Refer to the schematic for the respective...

Page 4: ...the angle the farther from the door the pattern will be The 0 angle should only be used when the Bodyguard is mounted to a BodyMount block or to a soffett above the door that extends out from the face...

Page 5: ...eck to ensure that the voltage from the motor at the red and black wire of the lockout has at least 10 volts DC A voltage that is too low may not be recognized by the lockout 2 If the door goes to the...

Page 6: ...nctions may be independently adjusted for each door position Sensitivity Pattern Width Pattern Depth 2 The following functions apply to both door closed and door open positions Automatic Learn Time Im...

Page 7: ...FF Interface 1 New Style 2 LO21 Old Style LO21 B K P S U DPHUB MC15 Infrared Frequency Mode Frequency 1 Normal Low 2 Normal High 3 Quiet Low 4 Quiet High See QUIET MODE Number Keys Number keys 0 throu...

Page 8: ...ight Wide 9 Center Narrow See PATTERN WIDTH or DEPTH Pattern Depth 1 Deep Threshold ON 2 Medium Threshold ON open 3 Limited Threshold ON 4 Deep Threshold OFF 5 Medium Threshold OFF closed 6 Limited Th...

Page 9: ...icate the setting of the particular parameter NOTE Pressing PB1 will toggle between the parameters and pressing PB2 will toggle between the range of adjustments for that particular setting Once you ac...

Page 10: ...21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 2...

Page 11: ...sity lighting 4 See problem IV probable cause 3 3 Ensure that no high intensity lighting is in the immediate area of the sensor 1 Ensure that there is no detection occurring at the Bodyguard If the Re...

Page 12: ...R with the use of a hold open switch While the door is open unlock the Bodyguard and press the setup key followed by the number 2 If the sensor goes back to a red LED as opposed to flashing the green...

Page 13: ...do daily inspections and calling out location of cutoff switches to put equipment out of service if a deficiency is noted The equipment should be inspected in accordance with the minimum inspection g...

Reviews: