Page 18
Controls:
•
Adjusting the timer function:
•
While the blower (motor) is not running, press and hold
•
Decrease Value
button over 3 seconds to
enter timer mode. Adjust to desired period of delay off timer by pressing
Increase Value
or
Decrease
Value
button (minimum 1 minute to maximum 9 minutes). This setting will be saved immediately.
Activating the timer function:
•
While the blower (motor) is running, press and hold
•
Power
button for over 3 seconds to activate
delay off timer.
Power-Off Delay Digital Timer
begin to countdown, when it reaches zero, the blower
(motor) will shut down.
Adjusting the light:
•
Press
•
Light
button once to turn on the lights, and once again to turn off the lights.
While the lights are off, press and hold
•
Light
button for over 3 seconds to dim the lights from high to
low. Level of brightness will be stored in system’s memory.
CAUTION: DO NOT touch the lights until switched OFF and cooled.
Note: Light settings are independent from other settings (including power-off delay) and lights has to be
manually turned on or off.
Note: The system saves user configurations, settings such as light, timer and blower (motor) speed will re
-
main the same the next time it is turned on.
Range Hood Operations & Wiring Diagram
(Continued)
SV168/198 Series “E” Class (4 or 6 Speed Electronic Touch Control)
Power
Power-Off Delay
Decrease Value
Light
Increase Value
Blower Speed Indicator
Power-Off Delay Digital Timer
Cleaning Reminder Indicator
Summary of Contents for SV198 Series
Page 2: ......
Page 29: ...Page 27 Your Notes...
Page 30: ...Your Notes Page 28...
Page 31: ...Your Notes Page 29...
Page 32: ...Aus Tex Appliance 113 Industrial Blvd D Austin TX 78745 Tel 512 444 2775...