3-4-2 Driver output test
The High Voltage will remain off for the following tests.
Set all controls to the standard setup condition. Power up, warm up 10 minutes. Remove the tube
shield from V18 and install the capacitive pickup and connect the scope. You will be testing all
bands. Adjustment of the PRESELECTOR and the driver grid and plate coils will be required for
each band. The process will be:
<Select band.
<Preset PRESELECTOR to proper band segment.
<Preset main tuning.
<KEY transmitter.
<Peak PRESELECTOR.
<Peak driver grid and plate coils as indicated in chart below.
<Record peak to peak voltage reading on scope.
BAND MAIN TUNING GRID COIL PLATE COIL VOLTAGE PEAK TO PEAK
80, 3.900 L11 L34 20 vpp
40, 7.23 L10 L33 28 vpp
20, 14.28 L9 L32 26 vpp
15, 21.36 L8 L31 25 vpp
10, 28.75 L7 L30 20 vpp
If any or all bands do not produce the peak to peak voltage noted go to 3-4-3.
3-4-2-1 PA FINAL PRETEST
:
When all faults have been cleared and the driver output is correct on all bands power down. Go get a cup of
coffee pick up the manual go to Section V of the manual and read the TUNING PROCEDURE. If necessary
review the FUNCTIONS OF OPERATING CONTROLS in section IV. Be very sure you understand all the
processes in the TUNING PROCEDURE. Any misstep from this point on could cost you a set of $1600 final
tubes. If you are unable to get normal power out you have a fault in the PA sub-circuits.
VOLTAGES IN THE
PA SUB-CIRCUITS ARE LETHAL. IF YOU ARE NOT EXPERIENCED IN HIGH VOLTAGE RF
TROUBLESHOOTING IT IS TIME TO FIND A MENTOR.
Go to section 5-5 for PA fault isolation.
NOTE: 18vpp on any band will drive Blue Burle tubes to saturation and the Green Burle tubes will
require 21vpp to fully saturate. The Black Burle tubes cannot be used in the SR-2000. For in-depth
discussions on the bias conditions and matching of the 8122 tubes go to
k9amx.com
.
3-4-3 TX second mixer output test
You have arrived at this point because one or more of the bands failed the tests in 3-4-2. If all bands were dead
conduct the test on 80 meters. Otherwise go the band that failed in 3-4-2.
Connect the scope to pin 2 of V18. Key the TX, you should have 6 vpp on pin 2 of V18. Disconnect the scope
and connect the frequency counter to pin 2 of V18. Key the TX and the counter should display the TX the
frequency determined by the band selection and the main tuning dial. If it is not there or the wrong frequency
you may have a fault in the 2
nd
TX mixer or its associated circuitry. Go to 3-4-4 TX second mixer input test.
Quick review: We got to this point because the initial driver output test failed. Once you establish proper signal
from the 2
nd
TX Mixer rerun the test in 3-4-2. If you still do not have proper drive levels you have a fault in the