17
1-11-1 CARRIER SUPPRESSION TEST AND ADJUSTMENT
Set up the 44 in the safe mode, power up and allow 15 minutes for warm up. The warm up is important, you
must insure all components are up to operating temperature.
Tune for max power in the center of any band in CW or AM.
•
Connect mic patch cable, adjust audio oscillator for 5mv, 1000Hz.
•
Set MIC GAIN to 8.
•
Set function to LSB
•
Set spectrum analyzer center freq to 7.23 MHz.
•
Key the transmitter and adjust the CARRIER BAL controls R8 and R13 for minimum carrier signal.
•
Unkey, switch to USB
•
Key up, check carrier suppression adjusting R8 and R13 to test for min carrier.
•
Go back and fourth from USB and LSB to insure carrier suppression is equal.
•
Return equipment to “safe” mode.