Hall Technologies HD-AUD-IO User Manual Download Page 9

Hall Technologies      October 6, 2023  

Page 9 of 16 

 

RS-232 commands

 

 

• 

The following table lists the available RS-232 commands:  

-

 

A single carriage return character (hex 0x0D) terminates each command.  

-

 

Invalid input, space and linefeed characters (hex 0x0A) are ignored.  

• 

RS-232 communication on the RS-232 terminal strip is:  

-

 

115200 bps, 8 Bit, No Parity, 1 Stop bit.  

• 

<CR> symbols in the table below refer to a single carriage return character (0x0D)  

• 

“Invalid Command” is sent in response to invalid RS-232 commands.  

• 

Other possible responses  

-

 

"ERR1" - Internal I2C error  

-

 

"ERR2" - TX HPD read error.  

-

 

"ERR3" - Chip Signature error  

 

Command  

Response  

Function and Example  

FW  

FWx.y<CR>  

Returns the firmware version.  

FW1.1<CR> -- X and Y represent the firmware version numbers. (V1.1)  

CVx  

CVx<CR>  

Sets/Returns the HDMI Output video status   
CV?<CR> -- Returns the current HDMI Output video status  
CV1<CR> -- Enable HDMI Output video 

(Factory Default)

  

CV0<CR> -- Disable HDMI Output video is OFF  

DI  

  

DIx<CR>  

Returns Digital Input Status  

DI1<CR> -- Digital Input terminal is not grounded.  

DI0<CR> -- Digital Input terminal is grounded.  

DIAx  

DIAx<CR>  

Sets/Returns Digital Input Action  

DIA?<CR> – Returns current Digital Input Action  

DIA3<CR> -- HDMI Output Audio is muted when digital input is 

grounded. 

(Factory Default)

  

  

Where 'x' is one of the following:  

0

 

-- No Action  

1

 

-- Mute HDMI Output Video and Audio  

2

 

-- Mute HDMI Output Video  

3

 

-- Mute HDMI Output Audio 

(Factory Default)

  

4

 

-- Mute Both External SPDIF and L/R Outputs  

5

 

-- Mute External LR Output  

6

 

-- Mute External SPDIF Output  

7

 

– Mute HDMI TX Output  

ESx  

ESx<CR>  

Sets/Returns the current EDID setting  
ES?<CR> -- Returns the current EDID setting  
ES1<CR>-- Pass-Thru EDID

 (Factory Default)

  

ES0<CR> -- Emulated EDID  

EL  

EL OK<CR>  
EL ERR<CR>  

Learns the connected SINK to the selected EDID (LR or Multi) 

EL OK<CR> -- The EDID learning process was completed EL 

ERR<CR> -- The EDID learning process was not completed. 

Failures can occur from:  

No SINK attached  

Attempting to learn while in EMULATED EDID mode  

Attempting to learn while in AUDIO EDID Pass-Thru mode  

FD  

FD<CR>  

Resets  device  to  Factory  Defaults  Unit  will 

reboot  

Summary of Contents for HD-AUD-IO

Page 1: ...Hall Technologies October 6 2023 Page 1 of 16 Hall Technologies 1234 Lakeshore Dr Suite 150 Coppell TX 75019 halltechav com HD AUD IO HDMI 2 0 Audio Inserter Extractor USER MANUAL October 6 2023...

Page 2: ...t obstruct the unit s ventilation openings with newspapers tablecloths curtains and similar items 4 Do not install near any heat sources such as radiators heat registers stoves or other apparatus incl...

Page 3: ...3 Page 3 of 16 Table of Contents Introduction 4 Overview 4 Features 5 Package Contents 5 Setup 6 Installation 6 Connectors and Indicators 7 RS 232 Commands 9 Windows Graphical User Interface 11 Troubl...

Page 4: ...SPDIF digital or 3 5mm L R analog Advanced EDID management allows users to control the video portion as well as the audio part of the EDID The EDID presented to the video source connected to the HDMI...

Page 5: ...in the HDMI input Embeds either LR analog or digital audio into the HDMI output Generates HDMI output with embedded audio with no HDMI input EDID management Can pass thru or emulate EDID RS 232 contro...

Page 6: ...R OUT analog audio output to a compatible device e g headphones assistive listening devices Optionally connect the audio to embed to the SPDIF IN and or L R IN connector s Optionally Connect the TX R...

Page 7: ...xternal RS 232 controller to control the HD AUD IO b Digital Input Connect to an external control for system output muting control based on the configured Digital Input Action 3 HDMI In Connect to a c...

Page 8: ...IO EDID Button and LEDs a 2 CH Alters EDID to include only 2CH audio settings b Multi Alters EDID to include only Mult Channel audio settings c Pass Pass EDID to source from SINK 6 VIDEO EDID Button a...

Page 9: ...is OFF DI DIx CR Returns Digital Input Status DI1 CR Digital Input terminal is not grounded DI0 CR Digital Input terminal is grounded DIAx DIAx CR Sets Returns Digital Input Action DIA CR Returns curr...

Page 10: ...state MUT CR Returns the current muting status Where x is one of the following 0 No Muting Factory Default 1 Mute HDMI Out Video and Audio 2 Mute HDMI Out Video 3 Mute HDMI Out Audio Both HDMI Out and...

Page 11: ...ng remove application Install the software by executing the SETUP EXE program from the installation source directory Accept the default settings but if you want to specify a particular installation di...

Page 12: ...e GUI can run at a time Executing the application more than once will result in a warning message Tool Bar Menu EXIT Exits the application TOOLS Factory Defaults Restore the device to factory default...

Page 13: ...ed mute setting which occurs when the DI digital input terminal connects to ground The indicator will be RED when the DI is un grounded and GREEN when the DI input connects to ground The factory defau...

Page 14: ...hooting suggestions Ensure that all connections to the device are solid Loose connections are the number one cause of issues Try resetting the system by unplugging BOTH the power supply and HDMI IN co...

Page 15: ...d Rate 115200 N 8 1 Digital Input Dry Contact connect to ground to trigger configured action General Power Supply 100 VAC to 240 VAC 47 63 Hz External 5 VDC 1 0 ADC Temp humidity Storage 40 to 158 F 4...

Page 16: ...Hall Technologies October 6 2023 Page 16 of 16 Copyright 2023 Hall Technologies All rights reserved 1234 Lakeshore Drive Coppell TX 75019 halltechav com support halltechav com 800 959 6439...

Reviews: